Contactless Carotid Pulse Measurement Using Continuous Wave Radar

被引:0
|
作者
Shi, Kilin [1 ]
Schellenberger, Sven [2 ]
Steigleder, Tobias [3 ,4 ]
Michler, Fabian [1 ]
Lurz, Fabian [1 ]
Weigel, Robert [1 ]
Koelpin, Alexander [2 ]
机构
[1] Friedrich Alexander Univ Erlangen Nuremberg, Inst Elect Engn, D-91058 Erlangen, Germany
[2] Brandenburg Tech Univ Cottbus, Chair Elect & Sensor Syst, D-03046 Cottbus, Germany
[3] Univ Klinikum Erlangen, Dept Palliat Care, D-91054 Erlangen, Germany
[4] Univ Klinikum Erlangen, Dept Neurol, D-91054 Erlangen, Germany
关键词
biomedical monitoring; biomedical signal analysis; cardiovascular system; cw radar; medical sensors; radar signal analysis; ultrasound; MYOCARDIAL-INFARCTION; MEDIA THICKNESS; STROKE; STENOSIS; INTIMA; RISK;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cardiovascular diseases are one of the major causes of death. Regular checkups and preventive actions can drastically help reducing fatal incidences. This can be achieved by monitoring the carotid artery or rather the carotid pulse signal. Commonly, ultrasound devices are used for that purpose. However, these devices are costly, mostly stationary and their usage requires training and experience. This paper investigates the possible usage of radar systems as a contactless and low-cost alternative for carotid pulse measurements. Theoretical investigations reveal a linear relationship between the measurands of both devices and synchronous recordings from three test persons further confirm the feasibility of using radar systems as a potential device for monitoring cardiovascular diseases.
引用
收藏
页码:569 / 571
页数:3
相关论文
共 50 条
  • [41] Contactless radar technology of measurement of a product level in the tank
    Prokhorov, BM
    NEFTYANOE KHOZYAISTVO, 2005, (05): : 131 - 132
  • [42] On wave radar measurement
    Kevin Ewans
    Graham Feld
    Philip Jonathan
    Ocean Dynamics, 2014, 64 : 1281 - 1303
  • [43] On wave radar measurement
    Ewans, Kevin
    Feld, Graham
    Jonathan, Philip
    OCEAN DYNAMICS, 2014, 64 (09) : 1281 - 1303
  • [44] Contactless vital signs monitoring in macaques using a mm-wave FMCW radar
    Zhang, Jiajin
    Hu, Renjie
    Chen, Lichang
    Gao, Yu
    Wu, Dong-Dong
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [45] Pulse Wave Velocity Monitoring Using A mmWave Radar Network
    Antolinos, Elias
    Perez-Fernandez, Francisco N.
    Grajal, Jesus
    2023 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC, 2023, : 85 - 87
  • [46] COMPARISON OF DIFFERENT METHODS FOR CONTINUOUS MEASUREMENT OF PULSE-WAVE VELOCITY
    DAVID, E
    KENNER, T
    PESSENHOFER, H
    SCHWABERGER, G
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1975, 359 : R31 - R31
  • [47] Wave and Tidal Power measurement using HF radar
    Wyatt, Lucy R.
    OCEANS 2007 - EUROPE, VOLS 1-3, 2007, : 294 - 298
  • [48] Measurement of regional pulse-wave velocity using spatial compound imaging of the common carotid artery in vivo
    Nagaoka, Ryo
    Masuno, Genta
    Kobayashi, Kazuto
    Yoshizawa, Shin
    Umemura, Shin-ichiro
    Saijo, Yoshifumi
    ULTRASONICS, 2015, 55 : 92 - 103
  • [49] Signal Separation Using a Mathematical Model of Physiological Signals for the Measurement of Heart Pulse Wave Propagation With Array Radar
    Sakamoto, Takuya
    IEEE ACCESS, 2020, 8 (08): : 175921 - 175931
  • [50] Reliability assessment for pulse wave measurement using artificial pulse generator
    Chang, Chi-Wei
    Wang, Wei-Kung
    Journal of Medical Engineering and Technology, 2015, 39 (03): : 177 - 184