Trace element analysis by means of synchrotron radiation, XRF, and PIXE: selection of sample preparation procedure

被引:14
|
作者
Kwiatek, WM
Kubica, B
Paluszkiewicz, C
Galka, M
机构
[1] Inst Nucl Phys, PL-31342 Krakow, Poland
[2] Jagiellonian Univ, Reg Lab, PL-30059 Krakow, Poland
[3] Stanislaw Staszic Univ Min & Met, PL-30059 Krakow, Poland
[4] Gabriel Narutowicz Hosp, PL-31202 Krakow, Poland
关键词
trace elements; sample preparation; synchrotron radiation; XRF; PIXE;
D O I
10.1016/S0925-8388(01)01318-4
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
When it comes to biological samples, trace element (TE) determination has to cope with very low concentrations, sometimes even below the minimum detectable limit (MDL). This is why special sample preparation procedures have to be employed so that the TE concentration in the specimen is effectively enhanced in a known way. The aim of this study was the selection of a proper sample preparation procedure by determination of selected element concentrations in different types of biological samples. In this work several sample preparation procedures were applied in order to choose the best one for specific experimental needs. The methods included: (a) tissue sectioning method (if appropriate); (b) dry method without chemical treatment - the samples were dried, homogenized and pressed into pellet; (c) wet method with chemical treatment - the samples were mineralized. The analyses were performed with different analytical methods in order to confirm the results obtained and in order to determine the influence of target preparation procedure on the level of elemental concentrations determination. The measurements were done by means of SRIXE (synchrotron radiation induced X-ray emission), EDXRF (energy dispersive X-ray fluorescence), TR-XRF (total reflection X-ray fluorescence), and PIXE (proton-induced X-ray emission). The above methods are described and the analytical results discussed. The results of the elemental analyses per-formed with different techniques show a good agreement only for some elements. The mineralization process increases the sensitivity of elemental determination only for selected elements. In other cases one could observe decreasing of elemental concentration in respect to non mineralized samples. Selection of sample preparation procedure depends on analytical requirements. (C) 2001 Elsevier Science BY All rights reserved.
引用
收藏
页码:283 / 288
页数:6
相关论文
共 50 条
  • [21] SAMPLE PREPARATION TECHNIQUES IN TRACE-ELEMENT ANALYSIS OF WATER
    NAGJ, M
    JAKSIC, M
    ORLIC, I
    VALKOVIC, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 236 (03): : 563 - 567
  • [22] Environment-sensitive trace element concentration in speleothems as detected by synchrotron μ-XRF
    Frisia, S.
    Borsato, A.
    Somogyi, A.
    Fairchild, I. J.
    Susini, J.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (18) : A186 - A186
  • [23] TRACE-ELEMENT ANALYSIS IN BIOLOGICAL SAMPLES BY USING XRF SPECTROMETRY WITH SECONDARY RADIATION
    CESAREO, R
    VIEZZOLI, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (11): : 1209 - 1218
  • [24] TRACE-ELEMENT DETECTION SENSITIVITY IN PIXE ANALYSIS BY MEANS OF AN EXTERNAL PROTON-BEAM
    RAITH, B
    WILDE, HR
    ROTH, M
    STRATMANN, A
    GONSIOR, B
    NUCLEAR INSTRUMENTS & METHODS, 1980, 168 (1-3): : 251 - 257
  • [25] SAMPLE PREPARATION OF ARCHAEOLOGICAL MATERIALS FOR PIXE ANALYSIS
    MORALES, JR
    DINATOR, MI
    LLONA, F
    SAAVEDRA, J
    FALABELLA, F
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1994, 187 (01): : 79 - 89
  • [26] Determination of Trace Amount of Bromine Adsorbed on Aluminium Plates by Synchrotron Radiation XRF
    Kosaka, Satoru
    Takahashi, Naoko
    Nozaki, Hiroshi
    Furuhashi, Mototake
    BUNSEKI KAGAKU, 2019, 68 (10) : 801 - 804
  • [27] PIXE INDUCED XRF ANALYSIS OF TRACE AMOUNTS OF IRON IN PURE COPPER MATRIX
    QUYNH, LH
    DEMETER, I
    SZOKEFALVINAGY, Z
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 566 - 568
  • [28] THE APPLICATION OF SYNCHROTRON RADIATION TO MICROPROBE TRACE-ELEMENT ANALYSIS OF BIOLOGICAL SAMPLES
    GORDON, BM
    HANSON, AL
    JONES, KW
    POUNDS, JG
    RIVERS, ML
    SCHIDLOVSKY, G
    SPANNE, P
    SUTTON, SR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 45 (1-4): : 527 - 531
  • [29] THE USE OF SYNCHROTRON-RADIATION FOR TRACE-ELEMENT ANALYSIS OF BIOMEDICAL SAMPLES
    VALKOVIC, V
    MOSCHINI, G
    RIVISTA DEL NUOVO CIMENTO, 1993, 16 (10): : 1 - 55
  • [30] TRACE-ELEMENT DETERMINATION USING SYNCHROTRON RADIATION
    GIAUQUE, RD
    JAKLEVIC, JM
    THOMPSON, AC
    ANALYTICAL CHEMISTRY, 1986, 58 (04) : 940 - 944