Influence of Slenderness on Stress-Strain Behavior of Concrete-Filled FRP Tubes: Experimental Study

被引:35
|
作者
Vincent, Thomas [1 ]
Ozbakkaloglu, Togay [1 ]
机构
[1] Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA 5005, Australia
关键词
Concrete; High-strength concrete (HSC); Fiber reinforced polymer (FRP); Confinement; Columns; Stress-strain relations; Slenderness; HIGH-STRENGTH CONCRETE; AXIAL COMPRESSIVE BEHAVIOR; REINFORCED POLYMER TUBES; CONFINED CONCRETE; SEISMIC PERFORMANCE; COLUMNS; SQUARE; JACKETS; MODEL; MANUFACTURE;
D O I
10.1061/(ASCE)CC.1943-5614.0000489
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled fiber reinforced polymer (FRP) tubes (CFFTs) have received significant research attention over the last two decades, with recent experimental studies identifying significant benefits of CFFTs filled with high-strength concretes (HSC). However, many test parameters of high-strength CFFTs, such as specimen slenderness, remain experimentally limited. This paper presents an experimental investigation on the axial compressive behavior of 33 monotonically loaded circular normal-strength and high-strength CFFTs (NSCFFTs and HSCFFTs). The influence of specimen slenderness is investigated on test specimens with height-to-diameter ratios (H/D) of 1, 2, 3, and 5. The CFFT specimens were instrumented with numerous lateral strain gauges to examine the development of hoop strains along the specimen height and around specimen perimeter. The experimentally recorded stress-strain relationships are presented graphically and the ultimate axial stresses and strains, and FRP tube hoop strains at rupture are tabulated. The results indicate that specimens with a height-to-diameter ratio (H/D) of 1 outperform specimens with a H/D ratio of 2 to 5, with significantly increased strength and strain enhancements. The influence of slenderness on specimens with a H/D ratio between 2 and 5 was found to be significant in regards to axial strain enhancement, with a decrease observed as specimen slenderness increased. Conversely, the influence of slenderness on axial strength enhancement of specimens with a H/D ratio between 2 and 5 was found to be negligible. The strain results indicate that hoop rupture strains along the height of CFFTs become more uniform for specimens with higher amounts of confinement. On the other hand, the variation of hoop strains around the perimeter of CFFTs was not observed to be significantly influenced by slenderness, concrete strength or amount of confinement. (C) 2014 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Behavior of recycled aggregate concrete-filled basalt and carbon FRP tubes
    Xie, Tianyu
    Ozbakkaloglu, Togay
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 105 : 132 - 143
  • [22] Research on stress-strain relation of concrete confined with FRP tubes
    Department of Civil Engineering, Key Lab of Structural Engineering and Vibration, Tsinghua University, Beijing 100084, China
    不详
    Gongcheng Lixue, 2006, 9 (98-103):
  • [23] Experimental behavior of connections to concrete-filled steel tubes
    Schneider, SP
    Alostaz, YM
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1998, 45 (03) : 321 - 352
  • [24] THE INFLUENCE OF OVERLAP REGIONS ON AXIAL BEHAVIOUR OF CONCRETE-FILLED FRP TUBES
    Vincent, Thomas
    Ozbakkaloglu, Togay
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 450 - 457
  • [25] Experimental study on the tensile behavior of square concrete-filled steel tubes
    Zhou, Meng
    Fan, Jian-Sheng
    Tao, Mu-Xuan
    Nie, Jian-Guo
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 121 : 202 - 215
  • [26] STRAIN EFFICIENCY OF FRP JACKETS IN FRP-CONFINED CONCRETE-FILLED CIRCULAR STEEL TUBES
    Li, S. Q.
    Chen, J. F.
    Bisby, L. A.
    Hu, Y. M.
    Teng, J. G.
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2012, 12 (01) : 75 - 94
  • [27] Axial compressive behavior of seawater coral aggregate concrete-filled FRP tubes
    Wang, Jie
    Feng, Peng
    Hao, Tingyu
    Yue, Qingrui
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 147 : 272 - 285
  • [28] Effect of column parameters on axial compression behavior of concrete-filled FRP tubes
    Zhu, ZY
    Ahmad, I
    Mirmiran, A
    ADVANCES IN STRUCTURAL ENGINEERING, 2005, 8 (04) : 443 - 449
  • [29] Investigation of Key Column Parameters on Compressive Behavior of Concrete-filled FRP Tubes
    Ozbakkaloglu, Togay
    Zhang, Wen
    ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 779 - 783
  • [30] Axial and lateral stress-strain model for circular concrete-filled steel tubes with external steel confinement
    Kwan, A. K. H.
    Dong, C. X.
    Ho, J. C. M.
    ENGINEERING STRUCTURES, 2016, 117 : 528 - 541