Correction of C-arm projection matrices by 3D-2D rigid registration of CT-images using mutual information

被引:0
|
作者
Müller, U
Bruck, S
Hesser, J
Männer, R
机构
[1] Univ Mannheim, Inst Computat Med, D-68131 Mannheim, Germany
[2] Heidelberg Univ, Inst Computat Med, D-68131 Mannheim, Germany
来源
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The paper discusses rigid registration of a 3D volume to 2D projections based on Mutual-Information similarity measures. The experiments we conducted are similar to those of Zoellei. However, in order to obtain a stopping criterion we use the Resilient Backpropagation as optimizer.. Performing the registration on artificial images we obtain a speedup of approx. a factor of 10. We applied the matching approach to calibrate C-arm positions and found lateral movements of the detector of 0.5-1 nim in a given set of projections.
引用
收藏
页码:161 / 170
页数:10
相关论文
共 50 条
  • [21] 3D-2D registration for surgical guidance: effect of projection view angles on registration accuracy
    Uneri, A.
    Otake, Y.
    Wang, A. S.
    Kleinszig, G.
    Vogt, S.
    Khanna, A. J.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (02): : 271 - 287
  • [22] C-arm CT soft tissue 3-D imaging with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 3 - 6
  • [23] Automated 3D-2D projective registration of human facial images using edge features
    Haider, AM
    Kaneko, T
    INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 2001, 15 (08) : 1263 - 1276
  • [24] Evaluation of 3D-2D Registration Methods for Registration of 3D-DSA and 2D-DSA Cerebral Images
    Mitrovic, Uros
    Spiclin, Ziga
    Likar, Bostjan
    Pernus, Franjo
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [25] Registration of 2D to 3D joint images using phase-based mutual information
    Dalvia, Rupin
    Abugharbieh, Rafeef
    Pickering, Mark
    Scarvell, Jennie
    Smith, Paul
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [26] 3D-2D Registration of Cerebral Angiograms: A Method and Evaluation on Clinical Images
    Mitrovic, Uros
    Spiclin, Ziga
    Likar, Bostjan
    Pernus, Franjo
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (08) : 1550 - 1563
  • [27] Rigid Motion Compensation in Interventional C-arm CT Using Consistency Measure on Projection Data
    Frysch, Robert
    Rose, Georg
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT I, 2015, 9349 : 298 - 306
  • [28] 3D-2D Gesture reconstruction using monocular video information applied to a robotic arm
    Nope, Sandra
    Loaiza, Humberto
    Caicedo, Eduardo
    REVISTA FACULTAD DE INGENIERIA-UNIVERSIDAD DE ANTIOQUIA, 2010, (53): : 145 - 154
  • [29] Fast non-rigid registration and model-based segmentation of 3D images using mutual information
    Thiran, JP
    Butz, T
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 1504 - 1515
  • [30] Rigid Registration of Delayed-Enhancement and Cine Cardiac MR Images using 3D Normalized Mutual Information
    Chenoune, Y.
    Constantinides, C.
    El Berbari, R.
    Roullot, E.
    Frouin, F.
    Herment, A.
    Mousseaux, E.
    COMPUTING IN CARDIOLOGY 2010, VOL 37, 2010, 37 : 161 - 164