Correction of C-arm projection matrices by 3D-2D rigid registration of CT-images using mutual information

被引:0
|
作者
Müller, U
Bruck, S
Hesser, J
Männer, R
机构
[1] Univ Mannheim, Inst Computat Med, D-68131 Mannheim, Germany
[2] Heidelberg Univ, Inst Computat Med, D-68131 Mannheim, Germany
来源
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The paper discusses rigid registration of a 3D volume to 2D projections based on Mutual-Information similarity measures. The experiments we conducted are similar to those of Zoellei. However, in order to obtain a stopping criterion we use the Resilient Backpropagation as optimizer.. Performing the registration on artificial images we obtain a speedup of approx. a factor of 10. We applied the matching approach to calibrate C-arm positions and found lateral movements of the detector of 0.5-1 nim in a given set of projections.
引用
收藏
页码:161 / 170
页数:10
相关论文
共 50 条
  • [1] Correction of Patient Motion in C-Arm Cone-Beam CT Using 3D-2D Registration
    Ouadah, S.
    Jacobson, M.
    Stayman, J. W.
    Ehtiati, T.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3792 - 3793
  • [2] Effective incorporating spatial information in a mutual information based 3D-2D registration of a CT volume to X-ray images
    Zheng, Guoyan
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2010, 34 (07) : 553 - 562
  • [3] Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery
    Chang, Chih-Ju
    Lin, Geng-Li
    Tse, Alex
    Chu, Hong-Yu
    Tseng, Ching-Shiow
    APPLIED BIONICS AND BIOMECHANICS, 2015, 2015
  • [4] Effective Incorporation of Spatial Information in a Mutual Information Based 3D-2D Registration of a CT Volume to X-Ray Images
    Zheng, Guoyan
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 922 - 929
  • [5] 2-D/3-D REGISTRATION OF C-ARM CT VOLUMES WITH FLUOROSCOPIC IMAGES BY SPINES FOR PATIENT MOVEMENT CORRECTION DURING ELECTROPHYSIOLOGY
    Liao, Rui
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1213 - 1216
  • [6] 3-D MR and CT images registration using mutual information
    Lin, L
    Wong, EMC
    Wang, P
    Krishnan, SM
    Tsao, SY
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 252 - 253
  • [7] Correction of patient motion in cone-beam CT using 3D-2D registration
    Ouadah, S.
    Jacobson, M.
    Stayman, J. W.
    Ehtiati, T.
    Weiss, C.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (23): : 8813 - 8831
  • [8] Simultaneous 3D-2D image registration and C-arm calibration: Application to endovascular image-guided interventions
    Mitrovic, Uros
    Pernus, Franjo
    Likar, Bostjan
    Spiclin, Ziga
    MEDICAL PHYSICS, 2015, 42 (11) : 6433 - 6447
  • [9] An Optimized Spline-Based Registration of a 3D CT to a Set of C-Arm Images
    Jonic, S.
    Thevenaz, P.
    Zheng, G.
    Nolte, L. -P.
    Unser, M.
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2006, 2006
  • [10] Automatic Detection of Misalignment in Rigid 3D-2D Registration
    Mitrovic, Uros
    Spiclin, Ziga
    Likar, Bostjan
    Pernus, Franjo
    CLINICAL IMAGE-BASED PROCEDURES: TRANSLATIONAL RESEARCH IN MEDICAL IMAGING, 2014, 8361 : 117 - 124