On-chip electrical detection of parallel loop-mediated isothermal amplification with DG-BioFETs for the detection of foodborne bacterial pathogens

被引:17
|
作者
Duarte-Guevara, Carlos [1 ,2 ]
Swaminathan, Vikhram V. [2 ]
Reddy, Bobby, Jr. [2 ]
Huang, Jui-Cheng [3 ]
Liu, Yi-Shao [4 ]
Bashir, Rashid [5 ]
机构
[1] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[2] Univ Illinois, Micro & Nanotechnol Lab, Urbana, IL 61801 USA
[3] Taiwan Semicond Mfg Co, Design & Technol Platform, Hsinchu, Taiwan
[4] Delta Elect Inc, Res & Ecosyst, Singapore 417939, Singapore
[5] Univ Illinois, Dept Bioengn, Urbana, IL 61802 USA
关键词
ESCHERICHIA-COLI; RAPID DETECTION; FOOD SAFETY; DEVICES; BEEF; TRANSISTORS; STANDARDS; QUALITY; SENSOR; PANEL;
D O I
10.1039/c6ra19685c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The use of field effect transistors (FETs) as the transduction element for the detection of DNA amplification reactions will enable portable and inexpensive nucleic acid analysis. Transistors used as biological sensors, or BioFETs, minimize the cost and size of detection platforms by leveraging fabrication methods already well developed for electronics. Here, we report a dual-gate BioFET (DG-BioFET) array platform with 1024 x 1024 sensors that is used for on-chip electrical detection of loop-mediated isothermal amplification (LAMP) reactions that target food borne bacterial pathogens. The DG-BioFETs of our 7 x 7 mm 2 array are able to electrically detect pH changes that are triggered by nucleotide incorporation during LAMP elongation. Multiple 250 nL reactions can be simultaneously electrically monitored in our array that is divided in 30 micro-chambers with gold-coated anisotropically etched silicon wells that act both as reference electrode and confinement element. Our characterization results show that the goldbiased DG-BioFETs have a sensitivity of 32 mV pH(-1) (equivalent to 2 mA pH(-1)) and an average resolution of 0.5 pH units. This sensitivity is high enough to detect the pH changes triggered by the amplification reaction, but to maximize our signal-to-noise ratio and improve our quantitative conclusions we use a group of data analysis techniques that are available in our high-density platform that monitors each reaction with similar to 3500 independent BioFETs. We use redundancy techniques to minimize the overall standard deviation of our measurements, the Grubbs test to eliminate measurements outside the expected normal distribution, and reference micro-chambers to subtract the common noise. With these techniques we are capable of reducing the P value, of a t-test comparing positive and negative readings, from a typical 0.17 to 0.03. The platform that we present along with the analysis techniques that we developed allow the on-chip electrical detection and identification of E. coli O157 and S. typhi with parallel LAMP assays targeting eae and invA genes. The LAMP reactions are highly specific, without false positives, and our titration assays demonstrate a limit of detection of 23 CFU per reaction on chip.
引用
收藏
页码:103872 / 103887
页数:16
相关论文
共 50 条
  • [41] Detection of porcine parvovirus by loop-mediated isothermal amplification
    Chen, Chang-mu
    Cui, Shang-jin
    JOURNAL OF VIROLOGICAL METHODS, 2009, 155 (02) : 122 - 125
  • [42] Detection of fish nocardiosis by loop-mediated isothermal amplification
    Itano, T.
    Kawakami, H.
    Kono, T.
    Sakai, M.
    Journal of Applied Microbiology, 2006, 100 (06): : 1381 - 1387
  • [43] Recent advances in loop-mediated isothermal amplification (LAMP) for rapid and efficient detection of pathogens
    Garg, Nupur
    Ahmad, Farhan Jalees
    Kar, Sudeshna
    CURRENT RESEARCH IN MICROBIAL SCIENCES, 2022, 3
  • [44] Centrifugal loop-mediated isothermal amplification microdevice for rapid, multiplex and colorimetric foodborne pathogen detection
    Oh, Seung Jun
    Park, Byung Hyun
    Jung, Jae Hwan
    Choi, Goro
    Lee, Doh C.
    Kim, Do Hyun
    Seo, Tae Seok
    BIOSENSORS & BIOELECTRONICS, 2016, 75 : 293 - 300
  • [45] Rapid Detection of Bacterial Pathogens Causing Lower Respiratory Tract Infections via Microfluidic-Chip-Based Loop-Mediated Isothermal Amplification
    Lai, Jin-Xin
    Qin, Yu-Rong
    Liao, Yi-Wen
    Si, Yu-Ting
    Yuan, Quan
    Huang, Shi-Mei
    Tang, Yu-Rong
    Wang, Ji-Liang
    Wang, Liang
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (205):
  • [46] Isothermal Amplification Technologies for the Detection of Foodborne Pathogens
    Junliang Zhong
    Xihong Zhao
    Food Analytical Methods, 2018, 11 : 1543 - 1560
  • [47] Isothermal Amplification Technologies for the Detection of Foodborne Pathogens
    Zhong, Junliang
    Zhao, Xihong
    FOOD ANALYTICAL METHODS, 2018, 11 (06) : 1543 - 1560
  • [48] A loop-mediated isothermal amplification with bacterial enrichment assay for detection of Xanthomonas fragariae in strawberry
    Wang, H.
    Turechek, W.
    PHYTOPATHOLOGY, 2014, 104 (11) : 127 - 127
  • [49] Rapid and simple detection of eight major periodontal pathogens by the loop-mediated isothermal amplification method
    Miyagawa, Junko
    Maeda, Hiroshi
    Murauchi, Toshimitsu
    Kokeguchi, Susumu
    Yamabe, Kokoro
    Tanimoto, Ichiro
    Nishimura, Fusanori
    Fukui, Kazuhiro
    Takashiba, Shogo
    FEMS IMMUNOLOGY AND MEDICAL MICROBIOLOGY, 2008, 53 (03): : 314 - 321
  • [50] Rapid In-Field Detection of Airborne Pathogens Using Loop-Mediated Isothermal Amplification (LAMP)
    Bani, Alessia
    Whitby, Corinne
    Colbeck, Ian
    Dumbrell, Alex J.
    Ferguson, Robert M. W.
    MICROORGANISMS, 2024, 12 (12)