Natural circulation experiments at the ISB-VVER integral test facility and calculations using the code ATHLET

被引:0
|
作者
Krepper, E
机构
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
引用
收藏
页码:85 / 88
页数:4
相关论文
共 40 条
  • [31] Assessment of TASS/SMR code for a loss of coolant flow transient using results of integral type test facility
    Chung, Young-Jong
    Yang, Soo Hyung
    Bae, Kyoo Hwan
    ANNALS OF NUCLEAR ENERGY, 2016, 92 : 1 - 7
  • [32] TWO-PHASE NATURAL CIRCULATION EXPERIMENTS IN A TEST FACILITY MODELED AFTER THREE MILE ISLAND UNIT-2.
    Kiang, R.L.
    Electric Power Research Institute (Report) EPRI NP, 1981,
  • [33] Numerical study on natural circulation characteristics in FASSIP-02 experimental facility using RELAP5 code
    Antariksawan, A. R.
    Widodo, S.
    Juarsa, M.
    Haryanto, D.
    Kusuma, M. H.
    Putra, N.
    2ND INTERNATIONAL TROPICAL RENEWABLE ENERGY CONFERENCE (I-TREC) 2017, 2018, 105
  • [34] Preliminary Investigation of Natural Circulation Stability in FASSIP-01 Experimental Facility using RELAP5 Code
    Antariksawan, Anhar R.
    Widodo, Surip
    Juarsa, Mulya
    Giarno
    Kusuma, M. Hadi
    Putra, Nandy
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS 2017 (THERMOFLUID 2017), 2018, 2001
  • [35] Simulation of natural circulation experiments for heavy liquid metal coolant using HYDRA-IBRAE/LM code
    Ilyasova, O. H.
    Alipchenkov, V. M.
    Mosunova, N. A.
    Grudtsyn, Ya. V.
    PROGRESS IN NUCLEAR ENERGY, 2024, 173
  • [36] Simulation of loss of the residual heat removal system of BETHSY integral test facility using CATHARE thermal-hydraulic code
    Hassan, YA
    Troshko, AA
    NUCLEAR TECHNOLOGY, 1997, 119 (01) : 29 - 37
  • [37] Validation of the RELAP5 code for the modeling of flashing-induced instabilities under natural-circulation conditions using experimental data from the CIRCUS test facility
    Kozmenkov, Y.
    Rohde, U.
    Manera, A.
    NUCLEAR ENGINEERING AND DESIGN, 2012, 243 : 168 - 175
  • [38] Full-scale modelling of the MNSR reactor to simulate normal operation, transients and reactivity insertion accidents under natural circulation conditions using the thermal hydraulic code ATHLET
    Hainoun, A
    Alissa, S
    NUCLEAR ENGINEERING AND DESIGN, 2005, 235 (01) : 33 - 52
  • [39] 2-PHASE NATURAL CIRCULATION EXPERIMENTS IN THE RD-14M MULTIPLE-CHANNEL CANDU THERMAL-HYDRAULICS TEST FACILITY
    INGHAM, PJ
    BORGFORD, TA
    MALLORY, JP
    10TH ANNUAL CONFERENCE 1989 - CANADIAN NUCLEAR SOCIETY, PROCEEDINGS VOL 3, 1989, : C34 - C38
  • [40] An integral effect test of a complete loss of reactor coolant system flow rate for the SMART design using the VISTA-ITL facility and its simulation with the MARS-KS code
    Park, Hyun-Sik
    Jeon, Byong-Guk
    Bae, Hwang
    Shin, Yong-Cheol
    Yi, Sung-Jae
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2017, 54 (03) : 348 - 355