Acetabular Revision Total Hip Arthroplasty Using an Impacted Morselized Allograft and a Cementless Cup Minimum 10-Year Follow-Up

被引:23
|
作者
Lee, Joong-Myung [1 ]
Nam, Hee-Tae [1 ]
机构
[1] Natl Med Ctr, Dept Orthoped Surg, Seoul 100799, South Korea
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 07期
关键词
acetabular revision arthroplasty; impacted morselized allograft; cementless cup; BONE STOCK; CLASSIFICATION; REPLACEMENT; RECONSTRUCTION; MANAGEMENT;
D O I
10.1016/j.arth.2011.03.035
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was undertaken to analyze the clinical and radiologic results of acetabular revision arthroplasty using an impacted morselized allograft and a cementless cup and was performed on 71 hips of 62 patients who were followed up for a minimum of 10 years (10 years to 14 years 8 months; mean, 12 years). The acetabular bone defects were classified using the American Academy of Orthopaedic Surgeons Committee on the Hip and Paprosky classifications. Cement less hemispherical cups were inserted via a press-fit technique, using an impacted morselized allograft. The mean Harris hip score at the last follow-up visit was 92. Only 3 cases were re-revised, and the 12-year survival rate was thus 95.8%. The study shows that acetabular revision arthroplasty using an impacted morselized allograft and a cementless cup is an excellent treatment option.
引用
收藏
页码:1057 / 1060
页数:4
相关论文
共 50 条
  • [21] Modular cementless cup for total hip arthroplasty: Results at 4-year follow-up
    Bistolfi A.
    Massazza G.
    Rosso F.
    Ventura S.
    Lagalla F.
    Crova M.
    MUSCULOSKELETAL SURGERY, 2012, 96 (2) : 89 - 94
  • [22] Revision total knee arthroplasty using the Kinemax Plus Superstabilizer prosthesis: Minimum 10-year follow-up
    Harwin, SF
    KNEE, 2006, 13 (02): : 93 - 97
  • [23] Acetabular Augments Used in Revision Hip Arthroplasty: Minimum 10-year Follow-Up of Implant Survivorships, Functional Scores, and Radiographic Outcomes
    Braunstein, Doris
    Greenberg, Arieh
    Chaudhry, Faran
    Daud, Anser
    Sa, Oleg A.
    Gross, Allan E.
    Kuzyk, Paul R.
    JOURNAL OF ARTHROPLASTY, 2025, 40 (03): : 751 - 757
  • [24] TOTAL HIP-ARTHROPLASTY IN THE ANKYLOSED HIP - A 10-YEAR FOLLOW-UP
    STRATHY, GM
    FITZGERALD, RH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (07): : 963 - 966
  • [25] Acetabular reconstruction by impacted cancellous allografts in cementless total hip arthroplasty revision
    Bilgen, Omer Faruk
    Bilgen, Muhammet Sadik
    Oncan, Tevfik
    Danis, Mutlu
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2012, 46 (02) : 120 - 125
  • [26] 10-YEAR FOLLOW-UP OF THE CHARNLEY TOTAL HIP-ARTHROPLASTY
    CEDELL, CA
    SVENDLER, CA
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 308 - 308
  • [27] 3rd generation ceramic-on-ceramic cementless total hip arthroplasty: a minimum 10-year follow-up study
    Lau, Yeong J.
    Sarmah, Shashank
    Witt, Johan D.
    HIP INTERNATIONAL, 2018, 28 (02) : 133 - 138
  • [28] Cementless total hip arthroplasty with structural allograft for massive acetabular defect in hip revision
    Tian Jialiang
    Sun Li
    Hu Ruyin
    Tian Xiaobin
    中华创伤杂志英文版, 2014, 17 (06) : 331 - 334
  • [29] Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup -: A minimum ten-year follow-up
    Grübl, A
    Chiari, C
    Gruber, M
    Kaider, A
    Gottsauner-Wolf, F
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (03): : 425 - 431
  • [30] Cementless total hip arthroplasty with structural allograft for massive acetabular defect in hip revision
    Tian Jialiang
    Sun Li
    Hu Ruyin
    Tian Xiaobin
    CHINESE JOURNAL OF TRAUMATOLOGY, 2014, 17 (06) : 331 - 334