Low-Dose CT of the Paranasal Sinuses: Minimizing X-Ray Exposure with Spectral Shaping

被引:48
|
作者
Wuest, Wolfgang [1 ,2 ]
May, Matthias [1 ]
Saake, Marc [1 ]
Brand, Michael [1 ]
Uder, Michael [1 ]
Lell, Michael [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Radiol, Erlangen, Germany
[2] Inst Radiol, Maximilianspl 1, D-91054 Erlangen, Germany
关键词
Low dose; CT; Parasinus CT; Tin filtration; Spectral shaping; MULTIDETECTOR CT; ACUTE SINUSITIS; IMAGE QUALITY; NECK CT; RADIATION; REDUCTION; DIAGNOSIS; HEAD; EYE; CATARACT;
D O I
10.1007/s00330-016-4263-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Shaping the energy spectrum of the X-ray beam has been shown to be beneficial in low-dose CT. This study's aim was to investigate dose and image quality of tin filtration at 100 kV for pre-operative planning in low-dose paranasal CT imaging in a large patient cohort. In a prospective trial, 129 patients were included. 64 patients were randomly assigned to the study protocol (100 kV with additional tin filtration, 150mAs, 192x0.6-mm slice collimation) and 65 patients to the standard low-dose protocol (100 kV, 50mAs, 128 x 0.6-mm slice collimation). To assess the image quality, subjective parameters were evaluated using a five-point scale. This scale was applied on overall image quality and contour delineation of critical anatomical structures. All scans were of diagnostic image quality. Bony structures were of good diagnostic image quality in both groups, soft tissues were of sufficient diagnostic image quality in the study group because of a high level of noise. Radiation exposure was very low in both groups, but significantly lower in the study group (CTDIvol 1.2 mGy vs. 4.4 mGy, p < 0.001). Spectral optimization (tin filtration at 100 kV) allows for visualization of the paranasal sinus with sufficient image quality at a very low radiation exposure. aEuro cent Spectral optimization (tin filtration) is beneficial to low-dose parasinus CT aEuro cent Tin filtration at 100 kV yields sufficient image quality for pre-operative planning aEuro cent Diagnostic parasinus CT can be performed with an effective dose < 0.05 mSv.
引用
收藏
页码:4155 / 4161
页数:7
相关论文
共 50 条
  • [21] Noise properties of low-dose X-ray CT sinogram data in Radon space
    Wang, Jing
    Lu, Hongbing
    Liang, Zhengrong
    Eremina, Daria
    Zhang, Guangxiang
    Wang, Su
    Chen, John
    Manzione, James
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [22] Low-Dose X-ray CT Reconstruction Algorithm Using Shearlet Sparse Regularization
    Xiao, Dayu
    Zhang, Xiaotong
    Li, Jianhua
    Bao, Nan
    Kang, Yan
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (03) : 620 - 627
  • [23] cuMBIR: An Efficient Framework for Low-dose X-ray CT Image Reconstruction on GPUs
    Li, Xiuhong
    Liang, Yun
    Zhang, Wentai
    Liu, Taide
    Li, Haochen
    Luo, Guojie
    Jiang, Ming
    INTERNATIONAL CONFERENCE ON SUPERCOMPUTING (ICS 2018), 2018, : 184 - 194
  • [24] Region-Specific Dictionary Learning for Low-Dose X-Ray CT Reconstruction
    Xu, Q.
    Han, H.
    Xing, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3389 - 3389
  • [25] Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review
    Zhang, Hao
    Wang, Jing
    Zeng, Dong
    Tao, Xi
    Ma, Jianhua
    MEDICAL PHYSICS, 2018, 45 (10) : E886 - E907
  • [26] A Preliminary Study on Low-dose X-ray Imaging Using Parametric X-ray
    Sakae, Toshiro
    Hayakawa, Yasushi
    Takahashi, Yumiko
    Kuwada, Takao
    Nakao, Keisuke
    Nogami, Kyoko
    Inagaki, Manabu
    Tanaka, Toshinari
    Sato, Isamu
    Hirayama, Katsunori
    Sekiya, Kotarou
    Kaneda, Takashi
    Suemitsu, Masaaki
    Okada, Hiroyuki
    Yamamoto, Hirotsugu
    Hata, Saya
    Akimoto, Yoshiaki
    Fukumoto, Masahiko
    Makimura, Masaharu
    JOURNAL OF HARD TISSUE BIOLOGY, 2011, 20 (01) : 31 - 35
  • [27] Image Quality Improvement for Low Dose Exposure in the Sparse X-ray CT Scanner
    Kobayashi, Takashi
    Tanaka, Toshiyuki
    2015 54TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2015, : 41 - 44
  • [28] Low-dose abdominal computed tomography for detection of urinary stone disease - Impact of additional spectral shaping of the X-ray beam on image quality and dose parameters
    Dewes, Patricia
    Frellesen, Claudia
    Scholtz, Jan-Erik
    Fischer, Sebastian
    Vogl, Thomas J.
    Bauer, Ralf W.
    Schulz, Boris
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (06) : 1058 - 1062
  • [29] Exposure to Low-Dose X-Ray Radiation Alters Bone Progenitor Cells and Bone Microarchitecture
    Lima, Florence
    Swift, Joshua M.
    Greene, Elisabeth S.
    Allen, Matthew R.
    Cunningham, David A.
    Braby, Leslie A.
    Bloomfield, Susan A.
    RADIATION RESEARCH, 2017, 188 (04) : 433 - 442
  • [30] Low-dose, 4D myocardial perfusion with x-ray micro-CT
    Clark, D. P.
    Badea, C. T.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132