Magnet strength measurement in circular accelerators from beam position monitor data

被引:10
|
作者
Franchi, A. [1 ]
Tomas, R. [1 ]
Schmidt, F. [1 ]
机构
[1] CERN, Geneva, Switzerland
关键词
D O I
10.1103/PhysRevSTAB.10.074001
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Recent measurements of resonance terms suggested the extension of the existing technique to measure magnet strengths from turn-by-turn beam position monitor data. This article describes the algorithm to infer the magnet strength from the variation along the ring of the resonance terms and reports on the first measurement. Both the algorithm and the software written for the analysis of the data can be particularly useful in the commissioning period of an accelerator in order to find magnets with wrong strengths or polarities as well as magnets with large magnetic errors.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] European Waste Statistics data for a Circular Economy Monitor: Opportunities and limitations from the Amsterdam Metropolitan Region
    Sileryte, Rusne
    Sabbe, Arnout
    Bouzas, Vasileios
    Meister, Kozmo
    Wandl, Alexander
    van Timmeren, Arjan
    JOURNAL OF CLEANER PRODUCTION, 2022, 358
  • [42] Measurement of backscattered radiation from secondary collimator jaws into the beam monitor chamber from a dual energy linear accelerator
    Ravikumar, M
    Ravichandran, R
    STRAHLENTHERAPIE UND ONKOLOGIE, 2001, 177 (12) : 670 - +
  • [43] Measurement of Backscattered Radiation from Secondary Collimator Jaws into the Beam Monitor Chamber from a Dual Energy Linear Accelerator
    Manickam Ravikumar
    Ramamoorthy Ravichandran
    Strahlentherapie und Onkologie, 2001, 177 : 670 - 675
  • [44] Region of interest reconstruction from truncated data in circular cone-beam CT
    Yu, LF
    Xia, D
    Zou, Y
    Pan, XC
    Pelizzari, C
    Munro, P
    MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 412 - 418
  • [45] Region of interest reconstruction from truncated data in circular cone-beam CT
    Yu, Lifeng
    Zou, Yu
    Sidky, Emil Y.
    Pelizzari, Charles A.
    Munro, Peter
    Pan, Xiaochuan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) : 869 - 881
  • [46] Image reconstruction from cone-beam data on a circular short-scan
    Noo, F
    Heuscher, DJ
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 50 - 59
  • [47] Measurement of photon beam backscatter from collimators to the beam monitor chamber using target-current-pulse-counting and telescope techniques
    Yu, MK
    Sloboda, RS
    Mansour, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (07): : 1107 - 1117
  • [48] Prediction of damage position in beam structures based on measurement of the mode shape from strain response
    Department of Mechanical Engineering, Akita University, 1-1 Tegata Gakuen-machi, Akita-shi, Akita, 010-8502, Japan
    Nihon Kikai Gakkai Ronbunshu A, 2009, 753 (684-689):
  • [49] Beam characterization of FLASH from Hartmann data and measurement of the Wigner distribution function
    Schaefer, Bernd
    Floeter, Bernhard
    Mann, Klaus
    Keitel, Barbara
    Ploenjes, Elke
    Tiedtke, Kai
    ADVANCES IN X-RAY FREE-ELECTRON LASERS: RADIATION SCHEMES, X-RAY OPTICS, AND INSTRUMENTATION, 2011, 8078
  • [50] Joint Axis and Position Estimation from Inertial Measurement Data by Exploiting Kinematic Constraints
    Seel, Thomas
    Schauer, Thomas
    Raisch, Joerg
    2012 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS (CCA), 2012, : 45 - 49