A CASE STUDY OF LOW-ENERGY HOUSES IN NORTHERN ITALY

被引:0
|
作者
Salvalai, G. [1 ]
Zambelli, E. [1 ]
机构
[1] Politecn Milan, I-20133 Milan, Italy
关键词
low energy consumption; sustainable building; high thermal insulation; conservatory space;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In 2007, the "passive house" concepts were applied at the construction of 16 houses in Se kin Bergamo, Italy. Using a holistic design process characterized by the integration of architectural and technological choices, the ambitious target of 30 kWh/m(2)a was reached (useful energy). Passive strategies are used to keep the indoor comfort: very high insulating levels; high winter solar gains; small window area in the north facade with high performance; large openings and conservatory space in the south facade. The mechanical plant system is composed by solar photovoltaic panels installed on the south-facing roof; electrical radiant floor heating system; high efficiency electric boiler; mechanical ventilation with heat recovery. This paper shows a real example of a holistic design process integrating architectural, technological and energetic issues; the result is a low-energy building with a contemporary architecture that suite perfectly to the specific context.
引用
收藏
页码:169 / 172
页数:4
相关论文
共 50 条
  • [21] A low-energy building under arctic conditions - a case study
    Norling, Casper Roland
    Rode, Carsten
    Svendsen, Svend
    Kragh, Jesper
    Reimann, Gregers
    RESEARCH IN BUILDING PHYSICS AND BUILDING ENGINEERING, 2006, : 587 - 594
  • [22] GUATEMALAN CASE-STUDY: SITUATIONAL LOW-ENERGY INTAKE
    Vossenaar, Marieke
    ANNALS OF NUTRITION AND METABOLISM, 2017, 71 : 260 - 260
  • [24] CENTRE OF LOW-ENERGY BUILDINGS IN PISEK - A CASE STUDY FOR NZEB
    Matuska, Tomas
    Lain, Milos
    Zmrhal, Vladimir
    SUSTAINABLE BUILDING AND REFURBISHMENT FOR NEXT GENERATIONS, 2013, : 111 - 114
  • [25] A comparative case study of passive and low-energy residential buildings
    Mahdavi, A.
    Doppelbauer, E. M.
    Proeglhoef, C.
    RESEARCH ON BUILDING PHYSICS, 2010, : 441 - 446
  • [26] Humeral fractures due to low-energy trauma: an epidemiologicalsurvey in patients referred to a large emergency department in Northern Italy
    M. Pedrazzoni
    B. Abbate
    I. Verzicco
    A. Pedrazzini
    M. Benatti
    G. Cervellin
    Archives of Osteoporosis, 2015, 10
  • [27] EVALUATION OF FUNCTIONALITY OF A LOW-ENERGY HOUSE CASE STUDY: LOW-ENERGY HOUSE OF THE CENTRE OF ECOLOGICAL ACTIVITIES SLUNAKOV (CZECH REPUBLIC)
    Machar, Ivo
    GEOCONFERENCE ON NANO, BIO AND GREEN - TECHNOLOGIES FOR A SUSTAINABLE FUTURE, 2013, : 641 - 645
  • [28] Primary energy performance and perceived indoor environment quality in Finnish low-energy and conventional houses
    Holopainen, Rauno
    Salmi, Kari
    Kahkonen, Erkki
    Pasanen, Pertti
    Reijula, Kari
    BUILDING AND ENVIRONMENT, 2015, 87 : 92 - 101
  • [29] Sustainable Renovation and Low-Energy Retrofitting of Houses in Rural Areas of Southern China
    Hu, Xing
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON MACHINERY, ELECTRONICS AND CONTROL SIMULATION (MECS 2017), 2017, 138 : 23 - 30
  • [30] Air Tightness of Ventilation Ductwork in Recently Built Low-Energy and Conventional Houses
    Salmi, Kari
    Kahkonen, Erkki
    Holopainen, Rauno
    Pasanen, Pertti
    Reijula, Kari
    INTERNATIONAL JOURNAL OF VENTILATION, 2015, 13 (04) : 329 - 337