A CASE STUDY OF LOW-ENERGY HOUSES IN NORTHERN ITALY

被引:0
|
作者
Salvalai, G. [1 ]
Zambelli, E. [1 ]
机构
[1] Politecn Milan, I-20133 Milan, Italy
关键词
low energy consumption; sustainable building; high thermal insulation; conservatory space;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In 2007, the "passive house" concepts were applied at the construction of 16 houses in Se kin Bergamo, Italy. Using a holistic design process characterized by the integration of architectural and technological choices, the ambitious target of 30 kWh/m(2)a was reached (useful energy). Passive strategies are used to keep the indoor comfort: very high insulating levels; high winter solar gains; small window area in the north facade with high performance; large openings and conservatory space in the south facade. The mechanical plant system is composed by solar photovoltaic panels installed on the south-facing roof; electrical radiant floor heating system; high efficiency electric boiler; mechanical ventilation with heat recovery. This paper shows a real example of a holistic design process integrating architectural, technological and energetic issues; the result is a low-energy building with a contemporary architecture that suite perfectly to the specific context.
引用
收藏
页码:169 / 172
页数:4
相关论文
共 50 条
  • [1] Integrated Design of low-energy houses in Selvino, Italy
    Salvalai, G.
    Zambelli, E.
    Masera, G.
    Frontini, F.
    Ghilardi, G.
    PORTUGAL SB10: SUSTAINABLE BUILDING AFFORDABLE TO ALL - LOW COST SUSTAINABLE SOLUTION, 2010, : 807 - 813
  • [2] Energy performance of timber houses in Northern Italy
    Cappelletti, F.
    Peron, F.
    Romagnoni, P.
    Ceccotti, A.
    Fregonese, M.
    Research in Building Physics and Building Engineering, 2006, : 635 - 643
  • [3] AUXILIARY HEATERS FOR LOW-ENERGY HOUSES
    DUTT, G
    SOLAR AGE, 1985, 10 (01): : 15 - 17
  • [4] DESIGNING HOUSES FOR LOW-ENERGY CONSUMPTION
    BOYD, JS
    MICHIGAN COOPERATIVE EXTENSION SERVICE EXTENSION BULLETIN, 1977, (NE-11): : 1 - 2
  • [5] Economic analysis of passive houses and low-energy houses compared with standard houses
    Audenaert, A.
    De Cleyn, S. H.
    Vankerckhove, B.
    ENERGY POLICY, 2008, 36 (01) : 47 - 55
  • [7] Comparison of different windows for low-energy houses
    Juras, Peter
    Staffenova, Daniela
    Durica, Pavol
    RSP 2017 - XXVI R-S-P SEMINAR 2017 THEORETICAL FOUNDATION OF CIVIL ENGINEERING, 2017, 117
  • [8] Exploring the diffusion of low-energy houses: An empirical study in the European Union
    Olsthoorn, Mark
    Schleich, Joachim
    Faure, Corinne
    ENERGY POLICY, 2019, 129 : 1382 - 1393
  • [9] EFFICIENT HEATING AND COOLING SYSTEMS FOR LOW-ENERGY HOUSES
    Minea, Vasile
    JOURNAL OF GREEN BUILDING, 2012, 7 (04): : 16 - 35
  • [10] Indoor climate in low-energy houses - an interdisciplinary investigation
    Isaksson, Charlotta
    Karlsson, Fredrik
    BUILDING AND ENVIRONMENT, 2006, 41 (12) : 1678 - 1690