Characteristics of a gas-liquid separator with a partial condenser in the absorption refrigeration cycle for automotive air conditioning

被引:0
|
作者
Suzuki, Haruka [1 ]
Sato, Yui [1 ]
Tsujimori, Atsushi [2 ]
机构
[1] Kanto Gakuin Univ, Dept Mech Engn, 1-50-1 Mutsuurahigashi, Yokohama, Kanagawa 2368501, Japan
[2] Kanto Gakuin Univ, Grad Sch, 1-50-1 Mutsuurahigashi, Yokohama, Kanagawa 2368501, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2022年 / 9卷 / 04期
关键词
Refrigeration cycle; Absorption; Partial condenser; Heat-driven; Waste heat; HEAT;
D O I
10.1299/mej.22-00001
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Experimental absorption refrigeration equipment with a generator driven by waste heat was manufactured and tested, with 2,2,2-trifluoroethane/1-methylpyrrolidine as the working fluid pair. A plate generator was used to reduce the heat transfer distance and to decrease the start-up time. However, the flow paths of the plate generator were not large enough to separate the refrigerant vapor from the two-phase flow. Therefore, a gas-liquid separator was introduced, and a cooling coil was embedded as a partial condenser in the separator to cool the refrigerant vapor and to condense the absorbent contained within it, thus increasing the concentration of the refrigerant vapor. The separator successfully separated the refrigerant from the solution in all tested conditions. The cooling rate of the partial condenser was varied from 143 to 222 W by changing the flow rate of cooling water. Then, a calculation model for the partial condenser was constructed to analyze its characteristics. In the calculation model, the helical coil partial condenser was modeled by being divided into 10 horizontal columns. It was assumed that only the solution phase had the concentration distribution from the bulk flow to the liquidvapor interface. We show that a heat and mass transfer area of 0.04 m(2) is needed to achieve an outlet vapor concentration of 0.95.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Study on characteristics of wet compression-absorption refrigeration cycle with CO2-ionic liquid mixture
    Li, Kun
    Wu, Weidong
    Liang, Kunfeng
    Zhang, Hua
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 154
  • [42] A novel process for oxygen absorption from air using hollow fiber gas-liquid membrane contactor
    Banazadeh, H.
    Mousavi, S. M.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 193 : 283 - 288
  • [43] FLOW CHARACTERISTICS IN AIR LIFT TYPE BUBBLE COLUMN WITH A GAS-LIQUID SIMULTANEOUS INJECTION NOZZLE
    BANDO, Y
    KURAISHI, M
    NISHIMURA, M
    HASEGAWA, K
    HATTORI, M
    ARAFUKA, T
    WAKAZONO, H
    KAGAKU KOGAKU RONBUNSHU, 1987, 13 (03) : 332 - 339
  • [44] Design and flow field characteristics analysis of spiral-uniflow coupled gas-liquid separator with wide range of inlet gas volume fractions
    Zhong, Lin
    Guo, Xin-Cheng
    Cong-Bin, Yin
    Gou, Ru-Yi
    Wang, Guo-Rong
    Huang, Ze-Qi
    Wang, Dang-Fei
    SEPARATION SCIENCE AND TECHNOLOGY, 2025,
  • [45] Integrated Lab-in-Syringe Platform Incorporating a Membrane less Gas-Liquid Separator for Automatic Cold Vapor Atomic Absorption Spectrometry
    Giakisikli, Georgia
    Miro, Manuel
    Anthemidis, Aristidis
    ANALYTICAL CHEMISTRY, 2013, 85 (19) : 8968 - 8972
  • [46] Effect of solution pH on the characteristics of pulsed gas-liquid discharges and aqueous reactive species in atmospheric air
    Wang, Sen
    Zhou, Zikai
    Zhou, Renwu
    Fang, Zhi
    Cullen, Patrick. J.
    JOURNAL OF APPLIED PHYSICS, 2021, 130 (10)
  • [47] Gas-Liquid Mass Transfer Characteristics of CO2 Absorption in Azole-Functionalized Ionic Liquid Anhydrous Solvents
    Wang, Yitai
    Bai, Yinge
    Song, Fukang
    Zeng, Shaojuan
    Wang, Lulu
    Zhang, Xiangping
    Energy and Fuels, 2025, 39 (01): : 614 - 625
  • [48] Pre-combustion carbon dioxide capture by gas-liquid absorption for Integrated Gasification Combined Cycle power plants
    Padurean, Anamaria
    Cormos, Calin-Cristian
    Agachi, Paul-Serban
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2012, 7 : 1 - 11
  • [49] Development of a sequential injection system for trace mercury determination by cold vapour atomic absorption spectrometry utilizing an integrated gas-liquid separator/reactor
    Anthemidis, AN
    Zachariadis, GA
    Stratis, JA
    TALANTA, 2004, 64 (04) : 1053 - 1057
  • [50] The use of a membrane gas-liquid separator for flow injection hydride generation atomic absorption spectrometry on-line speciation and determination of As(III) and As(V)
    Krenzelok, M
    Rychlovsky, P
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1998, 63 (12) : 2027 - 2035