Treatment, residual chlorine and season as factors affecting variability of trihalomethanes in small drinking water systems

被引:7
|
作者
Dyck, Roberta [1 ]
Cool, Genevieve [2 ]
Rodriguez, Manuel [2 ]
Sadiq, Rehan [1 ]
机构
[1] Univ British Columbia Okanagan, Sch Engn, Kelowna, BC V1V 1V7, Canada
[2] Univ Laval, Ecole Super Amenagement Terr, Quebec City, PQ G1V 0A6, Canada
关键词
drinking water; residual chlorine; seasonal variability; small municipal systems; treatment technologies; trihalomethanes; DISINFECTION BY-PRODUCTS; TREATMENT PLANT; GREECE; MODEL;
D O I
10.1007/s11783-014-0750-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Seasonal variability in source water can lead to challenges for drinking water providers related to operational optimization and process control in treatment facilities. The objective of this study is to investigate seasonal variability of water quality in municipal small water systems (< 3000 residents) supplied by surface waters. Residual chlorine and trihalomethanes (THM) were measured over seven years (2003-2009). Comparisons are made within each system over time, as well as between systems according to the type of their treatment technologies. THM concentrations are generally higher in the summer and autumn. The seasonal variability was generally more pronounced in systems using chlorination plus additional treatment. Chloroform, total THM (TTHM) and residual chlorine concentrations were generally lower in systems using chlorination plus additional treatment. Conversely, brominated THM concentrations were higher in systems using additional treatment. Residual chlorine was highest in the winter and lowest in the spring and summer. Seasonal variations were most pronounced for residual chlorine in systems with additional treatment. There was generally poor correlation between THM concentrations and concentrations of residual chlorine. Further study with these data will be beneficial in finding determinants and indicators for both quantity and variability of disinfection byproducts and other water quality parameters.
引用
收藏
页码:171 / 179
页数:9
相关论文
共 50 条
  • [21] Change of bacterial water quality in drinking water distribution systems working with or without low chlorine residual
    Wricke, B
    Korth, A
    Petzoldt, H
    Krüger, M
    2ND WORLD WATER CONGRESS: WATER AND HEALTH-MICROBIOLOGY, MONITORING AND DISINFECTION, 2002, 2 (03): : 275 - 281
  • [22] A multivariate Bayesian network analysis of water quality factors influencing trihalomethanes formation in drinking water distribution systems
    Li, Rebecca A.
    McDonald, James A.
    Sathasivan, Arumugam
    Khan, Stuart J.
    WATER RESEARCH, 2021, 190
  • [24] Factors affecting drinking water biofiltration
    Liu, XB
    Huck, PM
    Slawson, RM
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2001, 93 (12): : 90 - 101
  • [25] Factors affecting the genotoxicity of drinking water
    Xu, Zhizhen
    Wang, Dongsheng
    Zhang, Rong
    Tang, Shichuan
    ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6, 2012, 518-523 : 922 - +
  • [26] Exposure to Trihalomethanes in Drinking Water and Risk of Small for Gestational Age Births
    Summerhayes, Richard
    Morgan, Geoffrey
    Edwards, Howard
    Lincoln, Douglas
    Earnest, Arul
    Rahman, Bayzid
    Beard, John
    EPIDEMIOLOGY, 2011, 22 (01) : S69 - S69
  • [27] Exposure to Trihalomethanes in Drinking Water and Small-for-gestational-age Births
    Summerhayes, Richard J.
    Morgan, Geoffrey G.
    Edwards, Howard P.
    Lincoln, Douglas
    Earnest, Arul
    Rahman, Bayzidur
    Beard, John R.
    EPIDEMIOLOGY, 2012, 23 (01) : 15 - 22
  • [28] Insight into mixed chlorine/chloramines conversion and associated water quality variability in drinking water distribution systems
    Pan, Renjie
    Zhang, Tian -Yang
    Zheng, Zheng-Xiong
    Ai, Jian
    Ye, Tao
    Zhao, Heng-Xuan
    Hu, Chen-Yan
    Tang, Yu-Lin
    Fan, Jing-Jing
    Geng, Bing
    Xu, Bin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 880
  • [29] Spatial diversity of chlorine residual in a drinking water distribution system
    Lee, LY
    Lu, CS
    Kung, SL
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2004, 130 (11) : 1263 - 1268
  • [30] Poor efficacy of residual chlorine disinfectant in drinking water to inactivate waterborne pathogens in distribution systems
    Payment, P
    CANADIAN JOURNAL OF MICROBIOLOGY, 1999, 45 (08) : 709 - 715