Simple fluorescence assay for quantification of OSCS in heparin

被引:19
|
作者
Luehn, Susanne [1 ]
Schiemann, Simone [1 ]
Alban, Susanne [1 ]
机构
[1] Univ Kiel, Inst Pharmaceut, D-24118 Kiel, Germany
关键词
Heparin; Quantification; Counterfeit drugs; Quality assurance/control; OSCS; Fluorescence assay; OVERSULFATED CHONDROITIN SULFATE; ADVERSE CLINICAL EVENTS; CONTAMINANT;
D O I
10.1007/s00216-010-3867-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In 2008, heparin contaminated with oversulfated chondroitin sulfate (OSCS) penetrated the worldwide market and was associated with severe adverse effects. Feasible and reliable methods to test heparin for adulteration are needed. The objective was to develop a simple approach based on a microplate assay for quantification of heparin and sulfated glycans using the fluorescent heparin sensor polymer-H (polymer-H assay). However, both heparin and OSCS concentration-dependently increase the fluorescence intensity (FI) of polymer-H, so that OSCS in heparin cannot be detected. The idea was a two-step procedure including, first, separation of heparin by degradation with heparinase I, and then measurement of the remaining OSCS. To achieve complete heparin (unfractionated heparin (UFH), enoxaparin) degradation, several conditions (e.g. incubation time and heparinase I concentration) were optimized by using the aXa assay for monitoring. Defined UFH/OSCS mixtures incubated in this way showed a concentration-dependent FI increase in the polymer-H assay (lambda ((em)) 330 nm, lambda ((ex)) 510 nm). The sensitivity was unexpectedly high with an LOD/LOQ of 0.5%/0.6% OSCS content in heparin. Further experiments testing UFH/OSCS mixtures in the aXa assay confirmed our hypothesis: OSCS inhibits heparinase I resulting in incomplete heparin degradation and thus an additional FI increase of polymer-H by intact heparin. This two-step microplate fluorescence assay is a sensitive, rapid, and simple method for quantification of OSCS in heparin. In contrast with (1)H NMR and CE, neither expensive equipment nor much experience are required. It could be applied not only in the quality control of heparin, but also in clinical practice, to check the applied heparin preparation when a patient suffers any adverse effect.
引用
收藏
页码:673 / 680
页数:8
相关论文
共 50 条
  • [41] A NEW, SIMPLE CHROMOGENIC SUBSTRATE ASSAY FOR HEPARIN AND HEPARIN-LIKE ANTI-FXA ACTIVITY IN PLASMA
    HOLMER, E
    SODERBERG, K
    FRIBERGER, P
    SORSKOG, L
    THROMBOSIS AND HAEMOSTASIS, 1985, 54 (01) : 29 - 29
  • [43] A Rapid and Simple HPLC Assay for Quantification of Capecitabine for Drug Monitoring Purposes
    Farkouh, Andre
    Ettlinger, Dagmar
    Schueller, Johannes
    Georgopoulos, Apostolos
    Scheithauer, Werner
    Czejka, Martin
    ANTICANCER RESEARCH, 2010, 30 (12) : 5207 - 5211
  • [44] Heparin identification test and purity test for OSCS in heparin sodium and heparin calcium by weak anion-exchange high-performance liquid chromatography
    Hashii, Noritaka
    Kawasaki, Nana
    Itoh, Satsuki
    Qin, Yan
    Fujita, Naho
    Hattori, Toshiaki
    Miyata, Kazuyoshi
    Bando, Aya
    Sekimoto, Yuko
    Hama, Takeshi
    Kashimura, Masaki
    Tatsumi, Masashi
    Mabuchi, Kazunori
    Namekawa, Hiroshi
    Sakai, Toru
    Hirose, Mio
    Dobashi, Sei
    Shimahashi, Hirotoshi
    Koyama, Sadatoshi
    Herr, Susanne Odgaard
    Kawai, Kenzo
    Yoden, Hikaru
    Yamaguchi, Teruhide
    BIOLOGICALS, 2010, 38 (05) : 539 - 543
  • [45] Modulating luminescence of Tb3+ with biomolecules for sensing heparin and its contaminant OSCS
    Hu, Yihui
    Guo, Wenjing
    Ding, Yubin
    Cheng, Hanjun
    Wei, Hui
    BIOSENSORS & BIOELECTRONICS, 2016, 86 : 858 - 863
  • [46] EFFECTS OF HEPARIN SODIUM ON GENTAMICIN-ASSAY MEASURED BY FLUORESCENCE POLARIZATION IMMUNOASSAY METHOD
    JACKSON, DS
    BERTINO, JS
    THERAPEUTIC DRUG MONITORING, 1984, 6 (03) : 319 - 321
  • [47] A new fluorescence "switch on" assay for heparin detection by using a functional ruthenium polypyridyl complex
    Cheng, Ting-Ting
    Yao, Jun-Liang
    Gao, Xing
    Sun, Wenliang
    Shi, Shuo
    Yao, Tian-Ming
    ANALYST, 2013, 138 (12) : 3483 - 3489
  • [48] A SIMPLE DNA-DEPENDENT FLUORESCENCE ENHANCEMENT ASSAY FOR CELL NUMBER
    ADAMS, CJ
    STORRIE, B
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1981, 29 (02) : 326 - 328
  • [49] A Simple Point-of-Care Microfluidic Immunomagnetic Fluorescence Assay for Pathogens
    Zhang, Rui-Qiao
    Liu, Shu-Lin
    Zhao, Wei
    Zhang, Wan-Po
    Yu, Xu
    Li, Yong
    Li, An-Jun
    Pang, Dai-Wen
    Zhang, Zhi-Ling
    ANALYTICAL CHEMISTRY, 2013, 85 (05) : 2645 - 2651
  • [50] A simple, rapid, and sensitive fluorescence assay for microsomal triglyceride transfer protein
    Athar, H
    Iqbal, J
    Jiang, XC