Simple fluorescence assay for quantification of OSCS in heparin

被引:19
|
作者
Luehn, Susanne [1 ]
Schiemann, Simone [1 ]
Alban, Susanne [1 ]
机构
[1] Univ Kiel, Inst Pharmaceut, D-24118 Kiel, Germany
关键词
Heparin; Quantification; Counterfeit drugs; Quality assurance/control; OSCS; Fluorescence assay; OVERSULFATED CHONDROITIN SULFATE; ADVERSE CLINICAL EVENTS; CONTAMINANT;
D O I
10.1007/s00216-010-3867-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In 2008, heparin contaminated with oversulfated chondroitin sulfate (OSCS) penetrated the worldwide market and was associated with severe adverse effects. Feasible and reliable methods to test heparin for adulteration are needed. The objective was to develop a simple approach based on a microplate assay for quantification of heparin and sulfated glycans using the fluorescent heparin sensor polymer-H (polymer-H assay). However, both heparin and OSCS concentration-dependently increase the fluorescence intensity (FI) of polymer-H, so that OSCS in heparin cannot be detected. The idea was a two-step procedure including, first, separation of heparin by degradation with heparinase I, and then measurement of the remaining OSCS. To achieve complete heparin (unfractionated heparin (UFH), enoxaparin) degradation, several conditions (e.g. incubation time and heparinase I concentration) were optimized by using the aXa assay for monitoring. Defined UFH/OSCS mixtures incubated in this way showed a concentration-dependent FI increase in the polymer-H assay (lambda ((em)) 330 nm, lambda ((ex)) 510 nm). The sensitivity was unexpectedly high with an LOD/LOQ of 0.5%/0.6% OSCS content in heparin. Further experiments testing UFH/OSCS mixtures in the aXa assay confirmed our hypothesis: OSCS inhibits heparinase I resulting in incomplete heparin degradation and thus an additional FI increase of polymer-H by intact heparin. This two-step microplate fluorescence assay is a sensitive, rapid, and simple method for quantification of OSCS in heparin. In contrast with (1)H NMR and CE, neither expensive equipment nor much experience are required. It could be applied not only in the quality control of heparin, but also in clinical practice, to check the applied heparin preparation when a patient suffers any adverse effect.
引用
收藏
页码:673 / 680
页数:8
相关论文
共 50 条
  • [1] Simple fluorescence assay for quantification of OSCS in heparin
    Susanne Lühn
    Simone Schiemann
    Susanne Alban
    Analytical and Bioanalytical Chemistry, 2011, 399 : 673 - 680
  • [2] Erratum to: Simple fluorescence assay for quantification of OSCS in heparin
    Susanne Lühn
    Simone Schiemann
    Susanne Alban
    Analytical and Bioanalytical Chemistry, 2011, 399 (3) : 1393 - 1393
  • [3] A Simple Fluorescence Assay for Quantification of Canine Neutrophil Extracellular Trap Release
    Jeffery, Unity
    Gray, Robert D.
    LeVine, Dana N.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (117):
  • [4] A simple fluorescence based assay for quantification of human immunodeficiency virus particle release
    Johannes Hermle
    Maria Anders
    Anke-Mareil Heuser
    Barbara Müller
    BMC Biotechnology, 10
  • [5] A simple fluorescence based assay for quantification of human immunodeficiency virus particle release
    Hermle, Johannes
    Anders, Maria
    Heuser, Anke-Mareil
    Mueller, Barbara
    BMC BIOTECHNOLOGY, 2010, 10
  • [6] Direct fluorescence assay for the quantification of heparin and low-molecular-weight heparins in clinical samples
    Szelke, H.
    Giese, C.
    Kraemer, R.
    Harenberg, J.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 843 - 843
  • [7] A continuous fluorescence assay for simple quantification of bile salt hydrolase activity in the gut microbiome
    Brandvold, Kristoffer R.
    Weavers, Jacqueline M.
    Whidbey, Christopher
    Wright, Aaron T.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [8] A continuous fluorescence assay for simple quantification of bile salt hydrolase activity in the gut microbiome
    Kristoffer R. Brandvold
    Jacqueline M. Weaver
    Christopher Whidbey
    Aaron T. Wright
    Scientific Reports, 9
  • [9] A fluorescence assay for the trace detection of protamine and heparin
    Pang, Shu
    Liu, Siyu
    Su, Xingguang
    RSC ADVANCES, 2014, 4 (49) : 25857 - 25862
  • [10] SIMPLE METACHROMATIC ASSAY METHODS FOR HEPARIN AND PROTAMINE
    JOHNSON, EA
    MULLOY, B
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 1976, 28 (11) : 836 - 837