Experimental study and analytical model of the bond behavior of corroded reinforcing steel bars in concrete

被引:34
|
作者
Zheng, Yue [1 ,2 ]
Zheng, Shan-Suo [1 ,2 ]
Yang, Lu [1 ,2 ]
Dong, Li-Guo [1 ,2 ]
Zhang, Yi-Bo [1 ,2 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian 710055, Peoples R China
基金
国家重点研发计划;
关键词
Reinforced concrete; Bond performance; Corrosion; Stirrups; Bond-slip relationship; Finite element simulation; SLIP BEHAVIOR; DEFORMED BARS; LOCAL BOND; CORROSION; STRENGTH; DEGRADATION; PERFORMANCE;
D O I
10.1016/j.conbuildmat.2022.126991
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The corrosion of longitudinal rebar and stirrups will cause serious degradation of the bond performance between steel bars and concrete. To investigate the impact of both longitudinal rebar and stirrup corrosion on the bond behavior, 35 reinforced concrete (RC) pull-out specimens were subjected to accelerated corrosion tests with electroosmosis/constant current/dry-wet cycling and pull-out tests. The influence laws of the degree of corrosion of the longitudinal reinforcement, degree of corrosion of the stirrups, cover thickness, stirrup spacing and longitudinal reinforcement diameter on the bond performance were also investigated. The bond behavior between corroded steel bars and concrete was analyzed from the aspects of corrosion form, failure mode and bond strength. Subsequently, based on the experimental data, a modified bond-slip constitutive model that considers the design parameters, stirrup corrosion and longitudinal rebar corrosion was built and verified. The modified bond-slip constitutive model was applied to the cohesive element to establish a finite element model of the corroded pull-out specimens, and additional parameters were analyzed.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Experimental study on the bond behavior between corroded steel rebars and recycled aggregate concrete
    Lei, Bin
    Xiao, Jianzhuang
    Yan, Yusong
    Energy Education Science and Technology Part A: Energy Science and Research, 2013, 31 (01): : 581 - 584
  • [32] EXPERIMENTAL STUDY ON THE RESIDUAL CAPACITY OF CORRODED REINFORCING BARS
    Xu, Gang
    Ai, Tian-Cheng
    Zhang, Wei-Jun
    Wang, Qing
    4TH INTERNATIONAL SYMPOSIUM ON LIFETIME ENGINEERING OF CIVIL INFRASTRUCTURE, 2009, : 424 - 429
  • [33] Effect of confinement on bond between corroded steel bars and concrete
    Fang, C.
    ISISS 2005: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOL 1-3, 2005, : 934 - 943
  • [34] Seismic Behavior of Reinforced Concrete Columns with Corroded Deformed Reinforcing Bars
    Goksu, Caglar
    Ilki, Alper
    ACI STRUCTURAL JOURNAL, 2016, 113 (05) : 1053 - 1064
  • [35] Bond behaviour of normal/recycled concrete and corroded steel bars
    Zhao, Yuxi
    Lin, Hongwei
    Wu, Kang
    Jin, Weiliang
    CONSTRUCTION AND BUILDING MATERIALS, 2013, 48 : 348 - 359
  • [36] Early age bond-slip behavior of reinforcing steel bars in concrete subjected to uniaxial lateral pressure: An experimental study
    Wang, Yan-Jie
    Li, Wen-Ming
    Wu, Zhi-Min
    Liu, Hong-Bo
    STRUCTURES, 2024, 70
  • [37] Analytical modelling of bond between FRP reinforcing bars and concrete
    Cosenza, E.
    Manfredi, G.
    Realfonzo, R.
    1995,
  • [38] Fatigue bond behavior between corroded reinforcing bar and concrete
    Wu, Jieqiong
    Zhang, Zijian
    Jin, Liu
    Zhang, Xiaowang
    Du, Xiuli
    ENGINEERING STRUCTURES, 2025, 325
  • [39] BOND OF CONCRETE REINFORCING BARS
    CLARK, AP
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1949, 43 (06): : 565 - 579
  • [40] Degradation model of bond performance between deteriorated concrete and corroded deformed steel bars
    Wu, Yuan-Zhou
    Lv, Heng-Lin
    Zhou, Shu-Chun
    Fang, Zhong-Nian
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 119 : 89 - 95