Estimation of active multiple tuned mass dampers for asymmetric structures

被引:9
|
作者
Li, Chunxiang [1 ]
Xiong, Xueyu [2 ]
机构
[1] Shanghai Univ, Dept Civil Engn, Shanghai 200072, Peoples R China
[2] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
关键词
vibration control; damping; active multiple tuned mass dampers (AMTMD); asymmetric structures; ground acceleration; torsional to translational frequency ratio (TTFR); normalized eccentricity ratio (NER);
D O I
10.12989/sem.2008.29.5.505
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper proposes the application of active multiple tuned mass dampers (AMTMD) for translational and torsional response control of a simplified two-degree-of-freedom (2DOF) structure, able to represent the dynamic characteristics of general asymmetric structures, under the ground acceleration. This 2DOF structure is a generalized 2DOF system of an asymmetric structure with predominant translational and torsional responses under earthquake excitations using the mode reduced-order method. Depending on the ratio of the torsional to the translational eigenfrequency, i.e. the torsional to translational frequency ratio (TTFR), of asymmetric structures, the following three cases can be distinguished: (1) torsionally flexible structures (TTFR < 1.0), (2) torsionally intermediate stiff structures (TTFR = 1.0), and (3) torsionally stiff structures (TTFR > 1.0). The even distribution of the AMTMD within the whole width and half width of the asymmetric structure, thus leading to three cases of installing the AMTMD (referred to as the AMTMD of case 1, AMTMD of case 2, AMTMD of case 3, respectively), is taken into account. In the present study, the criterion for searching the optimum parameters of the AMTMD is defined as the minimization of the minimum values of the maximum translational and torsional displacement dynamic magnification factors (DMF) of an asymmetric structure with the AMTMD. The criterion used for assessing the effectiveness of the AMTMD is selected as the ratio of the minimization of the minimum values of the maximum translational and torsional displacement DMF of the asymmetric structure with the AMTMD to the maximum translational and torsional displacement DNIF of the asymmetric structure without the AMTMD. By resorting to these two criteria, a careful examination of the effects of the normalized eccentricity ratio (NER) on the effectiveness and robustness of the AMTMD are carried out in the mitigation of both the translational and torsional responses of the asymmetric structure. Likewise, the effectiveness of a single ATMD with the optimum positions is presented and compared with that of the AMTMD.
引用
收藏
页码:505 / 530
页数:26
相关论文
共 50 条
  • [31] Aseismic behaviors of active multiple tuned mass dampers for asymmetric buildings based on Kanai-Tajimi model
    Li, Chun-Xiang
    Wang, Chao
    Zhang, Li-Qing
    Zhendong yu Chongji/Journal of Vibration and Shock, 2007, 26 (10): : 68 - 75
  • [32] DESIGN OF SERIES MULTIPLE TUNED MASS DAMPERS FOR RESPONSE CONTROL OF ASYMMETRIC BUILDINGS
    Wang, Jer-Fu
    Li, Jie-Chun
    Lin, Chi-Chang
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, 2017, VOL 8, 2017,
  • [33] Control of Reinforced Concrete Frame Structures via Active Tuned Mass Dampers
    Kayabekir, Aylin Ece
    Bekdas, Gebrail
    Nigdeli, Sinan Melih
    PROCEEDINGS OF 7TH INTERNATIONAL CONFERENCE ON HARMONY SEARCH, SOFT COMPUTING AND APPLICATIONS (ICHSA 2022), 2022, 140 : 271 - 277
  • [34] Semi-active tuned mass dampers for seismic protection of civil structures
    Abe, M
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1996, 25 (07): : 743 - 749
  • [35] Semi-active tuned mass dampers for seismic protection of civil structures
    Univ of Tokyo, Tokyo, Japan
    Earthquake Engineering and Structural Dynamics, 1996, 25 (07): : 743 - 749
  • [36] Evaluation of elastically linked dashpot based active multiple tuned mass dampers for structures under ground acceleration
    Li, CX
    Qu, WL
    ENGINEERING STRUCTURES, 2004, 26 (14) : 2149 - 2160
  • [37] PROTECTION OF SEISMIC STRUCTURES USING PASSIVE AND SEMI-ACTIVE FRICTION TYPED MULTIPLE TUNED MASS DAMPERS
    Lin, Ging-Long
    Lin, Chi-Chang
    Wang, Jer-Fu
    ASME PRESSURE VESSELS AND PIPING CONFERENCE, VOL 8: SEISMIC ENGINEERING, 2010, : 279 - 287
  • [38] Tuned mass dampers for structures with bilinear hysteresis
    Abe, M
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1996, 122 (08): : 797 - 800
  • [39] Characteristics of active multiple tuned mass dampers for asymmetric buildings under seismic action - II: Torsional vibration control
    Li, Chun-Xiang
    Zhang, Li-Qing
    Zhendong yu Chongji/Journal of Vibration and Shock, 2007, 26 (08): : 50 - 54
  • [40] OPTIMAL VIBRATION CONTROL OF FLEXIBLE STRUCTURES UISNG MULTIPLE TUNED MASS DAMPERS
    Yang, Fan
    Sedaghati, Ramin
    Esmailzadeh, Ebrahim
    IMECE 2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 10, PTS A AND B, 2010, : 1077 - 1082