Comparative study of fractional flow reserve and diastolic pressure ratio using a guidewire with a sensor for measuring intravascular pressure

被引:0
|
作者
Kojima, Hiroki [1 ,2 ]
Ishii, Hideki [3 ,7 ]
Tanaka, Akihito [1 ]
Funakubo, Hiroshi [1 ]
Kato, Toshiaki [2 ]
Shimbo, Yusaku [4 ]
Kawamiya, Toshiki [5 ]
Kuwatsuka, Yachiyo [6 ]
Ando, Masahiko [6 ]
Murohara, Toyoaki [1 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Cardiol, Nagoya, Japan
[2] Nagoya Ekisaikai Hosp, Dept Cardiol, Nagoya, Japan
[3] Gunma Univ, Grad Sch Med, Dept Cardiovasc Med, Maebashi, Japan
[4] Kariya Toyota Gen Hosp, Dept Cardiol, Kariya, Japan
[5] Tsushima City Hosp, Dept Cardiol, Tsushima, Japan
[6] Nagoya Univ Hosp, Dept Adv Med, Nagoya, Japan
[7] Gunma Univ, Grad Sch Med, Dept Cardiovasc Med, 3-39-22 Showa machi, Maebashi 3718511, Japan
关键词
coronary artery; diastolic pressure ratio (dPR); fractional flow reserve (FFR); WAVE-FREE RATIO; CORONARY STENOSIS; MULTICENTER; IFR;
D O I
10.1097/MD.0000000000032578
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose:This study aimed to evaluate the correlation and diagnostic agreement between diastolic pressure ratio (dPR) and fractional flow reserve (FFR) in a Japanese real-world setting. Design:Prospective multicenter observational study Methods:This study included 100 patients with intermediate coronary artery stenosis at 4 Japanese hospitals. For these lesions, FFR and dPR were measured using a guidewire with a sensor and a monitor to measure intravascular pressure. The correlation and diagnostic agreement between FFR and dPR were assessed. When both FFR and dPR were negative or positive, the results were considered to be concordant. When one was positive and the other was negative, the result was regarded as discordant (positive discordance, FFR > 0.80 and dPR <= 0.89; negative discordance, FFR <= 0.80 and dPR > 0.89). Results:Overall, the FFR and dPR were well-correlated (R = 0.841). FFR and dPR were concordant in 89% of cases (concordant normal, 43%; concordant abnormal, 46%) and discordant in 11% (positive discordance, 7%; negative discordance, 4%). No significant difference was observed in the rate of concordant results between patients with and without diabetes mellitus. The diagnostic concordance rate was significantly different among the 3 coronary arteries (right coronary artery, 93.3%; left anterior descending artery, 93.2%; and left circumflex artery, 58.3%; P = .001). Additionally, the rate of concordant results tended to be higher when using intravenous administration of adenosine than when using intracoronary bolus injection of nicorandil (adenosine, 95.1%; nicorandil, 84.7%; P = .103). Conclusion:We found that dPR was highly correlated with FFR, and diagnostic discordance was observed in 11% of the lesions. Several factors, including lesion location and medication for hyperemia, may cause the diagnostic discordance between dPR and FFR.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Coronary pressure measurement and fractional flow reserve
    Pijls, NHJ
    De Bruyne, B
    HEART, 1998, 80 (06) : 539 - 542
  • [22] Prediction of fractional flow reserve using intravascular ultrasound
    Okubo, Munenori
    Kawasaki, Masanori
    Yagami, Hiroyuki
    Tanigaki, Toru
    Kawase, Yoshiaki
    Matsuo, Hitoshi
    Suzuki, Takahiko
    EUROINTERVENTION, 2024, 20 (19)
  • [23] Transradial Measurement of Transvalvular Pressure Gradient in the Setting of Mechanical Aortic and Mitral Valve Prostheses Using a Coronary Fractional Flow Reserve Guidewire
    Vales, Lori
    Cherukuri, Sanjay
    Kwan, Tak
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (02): : 72 - 73
  • [24] Reconciling Poststenotic Pressure With Hyperemic Flow Comparing Coronary Flow Reserve, Instantaneous Wave-Free Ratio, and Fractional Flow Reserve
    Kern, Morton J.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (04) : 432 - 434
  • [25] Fractional Flow Reserve, Coronary Pressure Wires, and Drift
    Pijls, Nico H. J.
    De Bruyne, Bernard
    CIRCULATION JOURNAL, 2016, 80 (08) : 1704 - 1706
  • [26] The Influence of Right Atrial Pressure on Fractional Flow Reserve
    Kumar, Gautam
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (10): : A43 - A44
  • [27] Fractional flow reserve: Who needs the pressure wire?
    Bartunek, J
    Pijls, NHJ
    Bech, GJW
    De Bruyne, B
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1999, 12 (06) : 425 - 430
  • [28] FIRST: Fractional Flow Reserve and Intravascular Ultrasound Relationship Study
    Waksman, Ron
    Legutko, Jacek
    Singh, Jasvindar
    Orlando, Quentin
    Marso, Steven
    Schloss, Timothy
    Tugaoen, John
    DeVries, James
    Palmer, Nicholas
    Haude, Michael
    Swymelar, Stacy
    Torguson, Rebecca
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (09) : 917 - 923
  • [29] Measuring pressure-derived fractional flow reserve through four French diagnostic catheters
    Legalery, P
    Seronde, MF
    Meneveau, N
    Schiele, F
    Bassand, JP
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (09): : 1075 - 1078
  • [30] Fractional flow reserve and intravascular ultrasound relationship study: the FIRST study
    Waksman, R.
    Torguson, R.
    Swymelar, S.
    Legutko, J.
    Singh, J.
    Orlando, Q.
    Marso, S.
    Schloss, T.
    Tugaoen, J.
    Devries, J.
    EUROPEAN HEART JOURNAL, 2012, 33 : 1000 - 1000