Determination of Rutin in Rat Plasma by Ultra Performance Liquid Chromatography Tandem Mass Spectrometry and Application to Pharmacokinetic Study

被引:19
|
作者
Chen, Mengchun [1 ]
Zhang, Xiaoqian [1 ]
Wang, Hao [1 ]
Lin, Baoli [1 ]
Wang, Shuanghu [2 ]
Hu, Guoxin [1 ]
机构
[1] Wenzhou Med Univ, Sch Pharm, Wenzhou 325035, Peoples R China
[2] Peoples Hosp Lishui City, Lab Clin Pharm, Lishui 323000, Zhejiang, Peoples R China
关键词
CAPILLARY-ELECTROPHORESIS; ELECTROCHEMICAL DETECTION; GARDENIA-JASMINOIDES; GENIPOSIDE; EXTRACTION; QUERCETIN; PHARMACEUTICALS; FLAVONOIDS; ELECTRODE; WATER;
D O I
10.1093/chromsci/bmu078
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS-MS) method for the determination of rutin in rat plasma was developed and validated. After addition of tolbutamide as internal standard (IS), protein precipitation by acetonitrile was used as sample preparation. The chromatographic separation was performed on an Acquity UPLC BEH C18 column (2.1 x 50 mm, 1.7 mu m particle size), using acetonitrile-0.1% formic acid as the mobile phase with gradient elution, delivered at a flow-rate of 0.4 mL/min. Mass spectrometric analysis was performed using a XEVO TQD mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 610.91 -> 302.98 and m/z 271.2 -> 155.1 were used to quantify for rutin and tolbutamide, respectively. This assay method has been fully validated in terms of specificity, linearity, recovery and matrix effect, accuracy, precision and stability. Calibration curves were linear in the concentration ranges of 25-2000 ng/mL for rutin. Only 3 min was needed for an analytical run. This developed method was successfully used for determination of rutin in rat plasma for pharmacokinetic study.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 50 条
  • [41] Development of a liquid chromatography/tandem mass spectrometry assay for the determination of bestatin in rat plasma and its application to a pharmacokinetic study
    Wang, Chen
    Fan, Guorong
    Lin, Mei
    Chen, Yi
    Zhao, Weiquan
    Wu, Yutian
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2): : 101 - 108
  • [42] Pharmacokinetic Study of Cephalomannine in Rat by Ultra-performance Liquid-Chromatography with Tandem Mass Spectrometry
    Geng, Peiwu
    Wang, Chunjie
    He, Yan
    Liu, Zezheng
    Yang, Suping
    Lin, Yingying
    Wen, Congcong
    Lin, Kezhi
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (04): : 748 - 753
  • [43] An Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Deoxycholic Acid and Application to a Pharmacokinetic Study in Human Plasma
    Xi, Wanlin
    Fu, Diyi
    Wu, Ni
    Liu, Fei
    Zhang, Cuixia
    Wan, Ruijie
    Wu, Zhen
    Chen, Rui
    Zhao, Qian
    BIOMEDICAL CHROMATOGRAPHY, 2025, 39 (02)
  • [44] Pharmacokinetic study of Syringin in Rat by Ultra-Performance Liquid-Chromatography Tandem Mass Spectrometry
    Hu, Liming
    Lin, Gaotong
    Zhang, Miaomiao
    Wang, Jifeng
    Wang, Shuanghu
    Wang, Bo
    LATIN AMERICAN JOURNAL OF PHARMACY, 2017, 36 (06): : 1231 - 1235
  • [45] Ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of febuxostat in dog plasma and its application to a pharmacokinetic study
    Zhang, Tianhong
    Sun, Yuanpeng
    Zhang, Peng
    Gao, Jingmei
    Wang, Shanshan
    He, Zhonggui
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (02) : 137 - 141
  • [46] Rapid determination of sumatriptan in human plasma by ultra performance liquid chromatography-tandem mass spectrometry and its application to clinical pharmacokinetic study
    Seo, Jeong Ju
    Park, Jeonghyeon
    Bae, Min Ho
    Lim, Mi-sun
    Seong, Sook Jin
    Lee, Joomi
    Park, Sung Min
    Lee, Hae Won
    Yoon, Young-Ran
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 919 : 38 - 42
  • [47] Determination of lovastatin in human plasma by ultra-performance liquid chromatography - electrospray ionization tandem mass spectrometry and its application in a pharmacokinetic study
    Yuan, Haiyan
    Wang, Feng
    Tu, Jiying
    Peng, Wenxing
    Li, Huande
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (04) : 808 - 813
  • [48] Determination of meloxicam in human plasma by ultra-high-performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
    Zhang, Siyao
    Chen, Shutong
    Song, Yujing
    Xin, Ying
    Cui, Ying
    Qin, Feng
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (08)
  • [49] Determination of zearalenone by liquid chromatography/tandem mass spectrometry and application to a pharmacokinetic study
    Shin, Beom Soo
    Hong, Seok Hyun
    Hwang, Sang Wook
    Kim, Hyoung Jun
    Lee, Jong Bong
    Yoon, Hae-Seong
    Kim, Do Jung
    Yoo, Sun Dong
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (09) : 1014 - 1021
  • [50] Determination of dapoxetine in rat plasma by ultra-performance liquid chromatography-tandem mass spectrometry
    Kim, Tae Kon
    Kim, In Sook
    Hong, Seok Hyun
    Choi, Yun Kyoung
    Kim, Hohyun
    Yoo, Hye Hyun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 926 : 42 - 46