Quasi-linear viscoelastic modeling of arterial wall for surgical simulation

被引:19
|
作者
Yang, Tao [1 ,2 ]
Chui, Chee Kong [2 ]
Yu, Rui Qi [3 ]
Qin, Jing [2 ]
Chang, Stephen K. Y. [4 ]
机构
[1] Inst Infocomm Res, Dept Comp Graph & Interface, Singapore, Singapore
[2] Natl Univ Singapore, Dept Mech Engn, Singapore 117548, Singapore
[3] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Surg, Singapore 117595, Singapore
[4] Natl Univ Singapore Hosp, Dept Surg, Singapore, Singapore
基金
英国医学研究理事会;
关键词
Constitutive modeling; Viscoelastic; Strain dependency; Arterial wall; Medical simulation; TENSILE FAILURE PROPERTIES; HUMAN AORTIC TISSUE; CONSTITUTIVE EQUATION; ARTICULAR-CARTILAGE; CORONARY-ARTERY; SOFT-TISSUE; STRAIN-RATE; MECHANICS; BEHAVIOR; STRESS;
D O I
10.1007/s11548-011-0560-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Realistic soft tissue deformation modeling and haptic rendering for surgical simulation require accurate knowledge of tissue material characteristics. Biomechanical experiments on porcine tissue were performed, and a reduced quasi-linear viscoelastic model was developed to describe the strain-dependent relaxation behavior of the arterial wall. This information is used in surgical simulation to provide a realistic sensation of reduction in strength when the user holds a virtual blood vessel strained at different levels. Twelve pieces of porcine abdominal artery were tested with uniaxial elongation and relaxation test in both circumferential and longitudinal directions. The mechanical property testing system consists of automated environment control, testing, and data collection mechanism. A combined logarithm and polynomial strain energy equation was applied to model the elastic response of the specimens. The reduced relaxation function was modified by integrating a rational equation as a corrective factor to precisely describe the strain-dependent relaxation effects. The experiments revealed that (1) stress is insensitive to strain rate in arterial tissue when the loading rate is low, and (2) the rate of stress relaxation of arterial wall is highly strain dependent. The proposed model can accurately represent the experimental data. Stress-strain function derived from the combined strain energy function is able to fit the tensile experimental data with R (2) equals to 0.9995 in circumferential direction and 0.999 in longitudinal direction. Modified reduced relaxation function is able to model the strain-dependent relaxation with R (2) equals to 0.9686 in circumferential direction and 0.988 in longitudinal direction. The proposed model, based on extensive biomechanical experiments, can be used for accurate simulation of arterial deformation and haptic rendering in surgical simulation. The resultant model enables stress relaxation status to be determined when subjected to different strain levels.
引用
收藏
页码:829 / 838
页数:10
相关论文
共 50 条
  • [21] On the thermodynamic consistency of Quasi-linear viscoelastic models for soft solids
    Berjamin, Harold
    Destrade, Michel
    Parnell, William J.
    MECHANICS RESEARCH COMMUNICATIONS, 2021, 111
  • [22] A quasi-linear viscoelastic constitutive equation for the brain: Application to hydrocephalus
    Drapaca, C. S.
    Tenti, G.
    Rohlf, K.
    Sivaloganathan, S.
    JOURNAL OF ELASTICITY, 2006, 85 (01) : 65 - 83
  • [23] Quasi-Linear Viscoelastic Model of the Articular Disc of the Temporomandibular Joint
    M.S. Commisso
    J.L. Calvo-Gallego
    J. Mayo
    E. Tanaka
    J. Martínez-Reina
    Experimental Mechanics, 2016, 56 : 1169 - 1177
  • [24] Quasi-Linear Viscoelastic Model of the Articular Disc of the Temporomandibular Joint
    Commisso, M. S.
    Calvo-Gallego, J. L.
    Mayo, J.
    Tanaka, E.
    Martinez-Reina, J.
    EXPERIMENTAL MECHANICS, 2016, 56 (07) : 1169 - 1177
  • [25] Estimation of the quasi-linear viscoelastic parameters using a genetic algorithm
    Kohandel, M.
    Sivaloganathan, S.
    Tenti, G.
    MATHEMATICAL AND COMPUTER MODELLING, 2008, 47 (3-4) : 266 - 270
  • [26] Numerical simulation of a relaxation test designed to fit a quasi-linear viscoelastic model for temporomandibular joint discs
    Commisso, Maria S.
    Martinez-Reina, Javier
    Mayo, Juana
    Dominguez, Jaime
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H2) : 190 - 199
  • [27] Methods for quasi-linear viscoelastic modeling of soft tissue: Application to incremental stress-relaxation experiments
    Sarver, JJ
    Robinson, PS
    Elliott, DM
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (05): : 754 - 758
  • [28] Quasi-Linear Viscoelastic Characterization of Soft Tissue-Mimicking Materials
    Helisaz, Hamed
    Bacca, Mattia
    Chiao, Mu
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2021, 143 (06):
  • [29] Energy dissipation in quasi-linear viscoelastic tissues, cells, and extracellular matrix
    Babaei, Behzad
    Velasquez-Mao, A. J.
    Prys, Kenneth M.
    McConnaughey, William B.
    Elson, Elliot L.
    Genin, Guy M.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 84 : 198 - 207
  • [30] Parameter estimation using the quasi-linear viscoelastic model proposed by Fung
    Dortmans, L.J.M.G.
    Sauren, A.A.H.J.
    Rousseau, E.P.M.
    Journal of Biomechanical Engineering, 1984, 106 (03) : 198 - 203