Online measurement of transformer partial discharge

被引:0
|
作者
Wang Baobao [1 ]
Yang Yang [2 ]
机构
[1] Xidian Univ, Network Secur & Comp Inst, S Taibai Rd 2, Xian, Shaanxi Prov, Peoples R China
[2] Xidian Univ, Coll Comp Sci, Xian, Peoples R China
关键词
partial discharge; time-delay; estimation; ultrasonic locating; the steepest; method; newton method;
D O I
10.1109/CIS.Workshops.2007.23
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In ultrasonic locating of transformer partial discharge (PD), the key technologies are time-delay (TD) estimation and PD point calculating, which directly determine the correctness and the precision of the results. The TD correlation algorithm has traits of convenient implementation and high precision. Based on the TD estimation, the hybrid unconstrained optimum method for solving the PD point locating equations realizes the specialties of fast iterative speed, wide convergence field and stable outcomes. Satisfying results are received while the algorithms are applied in the transformer PD point online detecting system.
引用
收藏
页码:906 / +
页数:2
相关论文
共 50 条
  • [31] Partial Discharge Propagation inside a High Voltage Transformer Winding: Comparison of Measurement and Simulation
    Abd Rahman, M. S.
    Rapisarda, P.
    Lewin, P. L.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 56 - 59
  • [32] Detection, Measurement, and Classification of Partial Discharge in a Power Transformer: Methods, Trends, and Future Research
    Mondal, Mithun
    Kumbhar, G. B.
    IETE TECHNICAL REVIEW, 2018, 35 (05) : 483 - 493
  • [33] Signal Extraction Methods for Online Partial Discharge (PD) Measurement of Power Transformers
    Seo, Junhyuck
    Ma, Hui
    Saha, Tapan
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 252 - 255
  • [34] A novel signal extraction technique for online partial discharge (PD) measurement of transformers
    Seo, Junhyuck
    Ma, Hui
    Saha, Tapan
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2016, 26 (05): : 1032 - 1048
  • [35] On-line partial discharge detection in transformer
    Ahmed, NH
    Srinivas, NN
    CONFERENCE RECORD OF THE 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1998, : 39 - 42
  • [36] Analysis of partial discharge test of UHV transformer
    Wu, Zhi-Rong
    Nie, De-Xin
    Chen, Jiang-Bo
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (01): : 54 - 61
  • [37] On-site Transformer Partial Discharge Diagnosis
    Gross, Detlev W.
    Soeller, Markus
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 558 - 564
  • [38] Practical location method of transformer partial discharge
    Li, YQ
    Lu, FC
    Xie, HL
    Yin, M
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 1371 - 1374
  • [39] STUDY ON PARTIAL DISCHARGE SIGNAL DENOISING OF TRANSFORMER
    Zheng, Yanyan
    Zhu, Yongli
    FRESENIUS ENVIRONMENTAL BULLETIN, 2020, 29 (4A): : 2707 - 2710
  • [40] RF detection of partial discharge in current transformer
    Chen, Mu-Kuen
    Chang, Wen-Yeau
    Chen, Jeng-Ming
    Cheng, Chao-Yuan
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 193 - 196