Dispersive liquid-liquid microextraction coupled with microfluidic paper-based analytical device for the determination of organophosphate and carbamate pesticides in the water sample

被引:6
|
作者
Beshana, Sheleme [1 ]
Hussen, Ahmed [1 ]
Leta, Seyoum [1 ]
Kaneta, Takashi [2 ]
机构
[1] Addis Ababa Univ, Coll Nat & Computat Sci, Ctr Environm Sci, POB 1176, Addis Ababa, Ethiopia
[2] Okayama Univ, Grad Sch Nat Sci & Technol, Dept Chem, Okayama 7008530, Japan
关键词
Pesticide; Dispersive liquid-liquid microextraction; Microfluidic paper-based analytical device; Box-Behnken design; Inhibition percent; CHROMATOGRAPHY-MASS SPECTROMETRY; GAS-CHROMATOGRAPHY; EXPERIMENTAL-DESIGN; SOLVENT-EXTRACTION; FUNGICIDES; RESIDUES; VOLUME; SOIL; AID;
D O I
10.1007/s44211-022-00167-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic paper-based analytical device (mu-PAD) is a promising new technology platform for the development of extremely low-cost sensing devices. However, it has low sensitivity that might not enable to measure maximum allowable concentration of various pollutants in the environment. In this study, a dispersive liquid-liquid microextraction (DLLME) was developed as a preconcentration method to enhance the sensitivity of the mu-PAD for trace analysis of selected pesticides. Four critical parameters (volume of n-hexane and acetone, extraction time, NaCl amount) that affect the efficiency of DLLME have been optimized using response surface methodology. An acceptable mean recovery of 79-97% and 83-93% was observed at 1 mu g L-1 and 5 mu g L-1 fortification level, respectively, with very good repeatability (2.2-6.01% RSD) and reproducibility (5.60-10.41% RSD). Very high enrichment factors ranging from 317 to 1471 were obtained. The limits of detection for the studied analytes were in the range of 0.18-0.41 mu g L-1 which is much lower than the WHO limits of 5-50 mu g L-1 for similar category of analytes. Therefore, by coupling DLLME with mu-PAD, a sensitivity that allows to detect environmental threat and also that surpassed most of the previous reports have been achieved in this study. This implies that the preconcentration step has a paramount contribution to address the sensitivity problem associated with mu-PAD.
引用
收藏
页码:1359 / 1367
页数:9
相关论文
共 50 条
  • [21] Dispersive liquid-liquid microextraction and liquid chromatographic determination of pentachlorophenol in water
    Farhadi, Khalil
    Farajzadeh, Mir A.
    Matin, Amir A.
    Hashemi, Paria
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2009, 7 (03): : 369 - 374
  • [22] Determination of Pyrethroid Pesticides in Tomato Using Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction
    Han, Dandan
    Tang, Baokun
    Row, Kyung Ho
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2014, 52 (03) : 232 - 237
  • [23] Dispersive Liquid-Liquid Microextraction for Preconcentration and Determination of Nickel in Water
    Lemos, Valfredo A.
    dos Santos Vieira, Emanuel V.
    Silva, Eldevan dos Santos
    dos Santos, Liz O.
    CLEAN-SOIL AIR WATER, 2012, 40 (03) : 268 - 271
  • [24] Dispersive liquid-liquid microextraction coupled to liquid chromatography for thiamine determination in foods
    Vinas, Pilar
    Lopez-Garcia, Ignacio
    Bravo-Bravo, Maria
    Briceno, Marisol
    Hernandez-Cordoba, Manuel
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (04) : 1059 - 1066
  • [25] Determination of Organophosphorus Pesticides in Soil by Dispersive Liquid-Liquid Microextraction and Gas Chromatography
    Yang, Zhonghua
    Liu, Yu
    Liu, Donghui
    Zhou, Zhiqiang
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (01) : 15 - 20
  • [26] Dispersive Liquid-Liquid Microextraction Coupled with Gas Chromatography for the Determination of Orthochlorophenol in Environmental Water Samples
    Yang, Yingchun
    Sun, Qian
    Yi, Chongshu
    Ye, Zhixiang
    Mo, Li
    ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6, 2012, 518-523 : 1379 - 1382
  • [27] Application of dispersive liquid–liquid microextraction combined with high-performance liquid chromatography to the determination of carbamate pesticides in water samples
    Qiuhua Wu
    Xin Zhou
    Yuemin Li
    Xiaohuan Zang
    Chun Wang
    Zhi Wang
    Analytical and Bioanalytical Chemistry, 2009, 393 : 1755 - 1761
  • [28] Determination of Vanadium in Environmental Water Samples by Dispersive Liquid-liquid Microextraction Coupled with Digital Colorimetry
    Ding Zongqing
    Zhang Qiongyao
    Liu Guangdong
    ACTA CHIMICA SINICA, 2009, 67 (17) : 1962 - 1966
  • [29] Surfactant-less water emulsion based dispersive liquid-liquid microextraction for determination of organophosphorus pesticides in aqueous samples
    Farajzadeh, Mir Ali
    Mogaddam, Mohammad Reza Afshar
    Esrafili, Leili
    ANALYTICAL METHODS, 2015, 7 (18) : 7899 - 7906
  • [30] Dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography-diode array detection for the determination of N-methyl carbamate pesticides in vegetables
    Lin, Xiangyun
    Chen, Xiaohui
    Huo, Xin
    Yu, Zhiguo
    Bi, Kaishun
    Li, Qing
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (02) : 202 - 209