Analysis of a dynamic voltage compensator with reduced switch-count and absence of energy storage system

被引:26
|
作者
Silva, SM [1 ]
da Silveira, SB
Reis, AD
Cardoso, BJ
机构
[1] HPE High Power Engn Ltda, BR-31270901 Belo Horizonte, MG, Brazil
[2] Univ Fed Minas Gerais, Dept Engn Elet, BR-31270010 Belo Horizonte, MG, Brazil
关键词
component-reduced converters; power quality; voltage sag compensators;
D O I
10.1109/TIA.2005.853382
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The utilization of dynamic voltage restorers to protect sensitive loads against short-term voltage disturbances has been proven to be a competitive solution in medium- and high-power applications. For low-power applications further cost reductions are required to make the technology even more competitive, although just a few numbers of studies have already been conducted in this area. This paper discusses the design and operation of a three-phase dynamic voltage compensator, including control strategies for the converters. The proposed topology and control strategies are evaluated through simulation studies based on measured data, selected by the IEEE Power Quality Task Force for the characterization of power quality events and device performance evaluation, along with disturbances recorded in a steel plant, in Minas Gerais State, Brazil. An experimental implementation of the compensator is developed to allow a better evaluation of specific and critical operating modes, such as the forced commutation of the bypass thyristors and inverter operation.
引用
收藏
页码:1255 / 1262
页数:8
相关论文
共 50 条
  • [31] Reduced switch count Asymmetric 13-Level Voltage Source Inverter
    Foti, S.
    Testa, A.
    De Caro, S.
    Cusumano, A.
    Scelba, G.
    2021 23RD EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'21 ECCE EUROPE), 2021,
  • [32] Design and analysis of a flywheel energy storage system fed by matrix converter as a dynamic voltage restorer
    Aydogmus, Omur
    Boztas, Gullu
    Celikel, Resat
    ENERGY, 2022, 238
  • [33] Voltage compensator based on a direct matrix converter without energy storage
    Lozano-Garcia, Jose M.
    Ramirez, Juan M.
    IET POWER ELECTRONICS, 2015, 8 (03) : 321 - 332
  • [34] The impact of energy storage on the dynamic performance of a static synchronous compensator
    Arsoy, A
    Liu, YL
    Ribeiro, PF
    Xu, WL
    IPEMC 2000: THIRD INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, PROCEEDINGS, 2000, : 519 - 524
  • [35] Dual ac-drive system with a reduced switch count
    Ledezma, E
    McGrath, B
    Muñoz, A
    Lipo, TA
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (05) : 1325 - 1333
  • [36] Reduced switch count dual-winding AC drive system with common-mode voltage mitigation
    Correa, MBD
    Jacobina, CB
    da Silva, CR
    Lima, AMN
    APEC 2005: TWENTIETH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-3, 2005, : 458 - 464
  • [37] Electrical Variable Capacitor of Reduced Switch Count and Voltage Stress for 13.56MHz RF Plasma System
    Min, Juhwa
    Suh, Yongsug
    2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, : 5933 - 5939
  • [38] Dynamic Voltage Restorer Based on Active Hybrid Energy Storage System
    Fu, Xueqian
    Chen, Haoyong
    Mo, Weike
    2014 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (IEEE PES APPEEC), 2014,
  • [39] Dynamic voltage restorer based on super capacitor energy storage system
    Yi, Guiping
    Hu, Renjie
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2013, 33 (12): : 21 - 26
  • [40] Dynamic Voltage Sag/Swell Compensator for Industrial Distribution System
    Venkatesh, C.
    Sarma, D. V. S. S. Siva
    Sydulu, M.
    JOURNAL OF ELECTRICAL SYSTEMS, 2010, 6 (04) : 530 - 548