Parametric investigation concerning dimensions of a stand-alone wind-power system

被引:19
|
作者
Kaldellis, JK [1 ]
机构
[1] TEI Piraeus, Dept Mech Engn, Lab Soft Energy Applicat & Environm Protect, Hellinco 16777, Greece
关键词
D O I
10.1016/S0306-2619(03)00101-6
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A detailed parametric analysis is carried out concerning the optimum sizing of a stand-alone wind-power system, used to ensure the electricity supply of several remote consumers. This study initially analyzes the impact of the available wind-potential quality on the dimensions of the main system's components. Accordingly, the influence of the specific wind-power curve-utilized on the proposed configuration sizing-is also examined. In addition, the system's minimum acceptable reliability contribution is investigated for determining the minimum cost stand-alone system dimensions. Finally, the consumer size effect is taken into consideration during the best choice selection process. Thus, by incorporating the proposed parametric analysis results in an appropriate decision-taking procedure, a significant reduction of the system dimensions may be realized, leading to a remarkably diminished first installation cost. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:35 / 50
页数:16
相关论文
共 50 条
  • [41] Stand-alone wind generation system with hybrid energy storage
    Lu, Wenzhou
    Zhou, Keliang
    Cheng, Ming
    Wang, Lina
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2011, 26 (02): : 165 - 172
  • [42] Passive MPPT method for stand-alone wind power generation systems
    Bai Y.
    Kou B.
    Chan C.C.
    Kou, Baoquan (koubq@hit.edu.cn), 1600, Central South University of Technology (48): : 370 - 380
  • [43] Development of Wind Turbine Emulator for Stand-alone Wind Energy Conversion System
    Himani
    Dahiya, Ratna
    2016 IEEE 6TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2016,
  • [44] A Peak Power Tracking Wind System Operating with a Controlled Load Structure for Stand-Alone Applications
    Druga, M.
    Nichita, C.
    Barakat, G.
    Dakyo, B.
    Ceanga, E.
    EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 4828 - 4836
  • [45] EFFICIENT ESTIMATOR OF PROBABILITIES OF LARGE POWER SPILLS IN AN STAND-ALONE SYSTEM WITH WIND GENERATION AND STORAGE
    Bhaumik, Debarati
    Crommelin, Daan
    Zwart, Bert
    2015 WINTER SIMULATION CONFERENCE (WSC), 2015, : 3178 - 3179
  • [46] Minimum stand-alone wind power system cost solution for typical Aegean Sea Islands
    Kaldellis, J.K.
    Wind Engineering, 2002, 26 (04) : 241 - 253
  • [47] A stand-alone wind power supply with a Li-ion battery energy storage system
    Mesbahi, Tedjani
    Ouari, Ahmed
    Ghennam, Tarak
    Berkouk, El Madjid
    Rizoug, Nassim
    Mesbahi, Nadhir
    Meradji, Moudrik
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 40 : 204 - 213
  • [48] Comparative Evaluation of Reactive Power Compensation Methods for a Stand-Alone Wind Energy Conversion System
    Elnashar, M.
    Kazerani, M.
    El Shatshat, R.
    Salama, M. M. A.
    2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, : 4539 - 4544
  • [49] Hydro-PV-Wind-Battery-Diesel Based Stand-Alone Hybrid Power System
    Rahman, M. M. Atiqur
    Al Awami, Ali T.
    Rahim, A. H. M. A.
    2014 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION & COMMUNICATION TECHNOLOGY (ICEEICT 2014), 2014,
  • [50] Power Management of a Variable Speed Wind Turbine for Stand-Alone System using Fuzzy Logic
    Huynh Quang Minh
    Frederic, Nollet
    Najib, Essounbouli
    Abdelaziz, Hamzaoui
    IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS (FUZZ 2011), 2011, : 1404 - 1410