A Control Systems Approach to Quantify Wall Shear Stress Normalization by Flow-Mediated Dilation in the Brachial Artery

被引:15
|
作者
van Bussel, Frank C. G. [1 ,2 ,7 ]
van Bussel, Bas C. T. [3 ,5 ]
Hoeks, Arnold P. G. [1 ,6 ]
Op't Roodt, Jos [3 ,6 ]
Henry, Ronald M. A. [3 ,6 ]
Ferreira, Isabel [3 ,4 ,6 ]
Vanmolkot, Floris H. M. [3 ,6 ]
Schalkwijk, Casper G. [3 ,6 ]
Stehouwer, Coen D. A. [3 ,5 ,6 ]
Reesink, Koen D. [1 ,6 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Biomed Engn, NL-6200 MD Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Radiol, NL-6200 MD Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Internal Med, NL-6200 MD Maastricht, Netherlands
[4] Maastricht Univ, Med Ctr, Dept Clin Epidemiol & Med Technol Assessment, NL-6200 MD Maastricht, Netherlands
[5] Maastricht Univ, Med Ctr, Sch Nutr Toxicol & Metab NUTRIM, NL-6200 MD Maastricht, Netherlands
[6] Maastricht Univ, Med Ctr, Sch Cardiovasc Dis CARIM, NL-6200 MD Maastricht, Netherlands
[7] Maastricht Univ, Med Ctr, Sch Mental Hlth & Neurosci MHeNS, NL-6200 MD Maastricht, Netherlands
来源
PLOS ONE | 2015年 / 10卷 / 02期
关键词
ENDOTHELIAL FUNCTION; ULTRASOUND ASSESSMENT; REPRODUCIBILITY; HYPERGLYCEMIA; DYSFUNCTION; VASODILATATION; AGREEMENT; RESPONSES; IMPAIRS; IMPACT;
D O I
10.1371/journal.pone.0115977
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Flow-mediated dilation is aimed at normalization of local wall shear stress under varying blood flow conditions. Blood flow velocity and vessel diameter are continuous and opposing influences that modulate wall shear stress. We derived an index FMDv to quantify wall shear stress normalization performance by flow-mediated dilation in the brachial artery. In 22 fasting presumed healthy men, we first assessed intra-and inter-session reproducibilities of two indices pFMD(v) and mFMD(v), which consider the relative peak and relative mean hyperemic change in flow velocity, respectively. Second, utilizing oral glucose loading, we evaluated the tracking performance of both FMDv indices, in comparison with existing indices [i.e., the relative peak diameter increase (%FMD), the peak to baseline diameter ratio (D-peak/D-base), and the relative peak diameter increase normalized to the full area under the curve of blood flow velocity with hyperemia (FMD/shear(AUC)) or with area integrated to peak hyperemia (FMD/shear(AUC_peak))]. Inter-session and intra-session reproducibilities for pFMD(v), mFMD(v) and %FMD were comparable (intra-class correlation coefficients within 0.521-0.677 range). Both pFMD(v) and mFMD(v) showed more clearly a reduction after glucose loading (reduction of similar to 45%, p <= 0.001) than the other indices (% given are relative reductions): %FMD (similar to 11%, p >= 0.074); D-peak/D-base (similar to 11%, p >= 0.074); FMD/shear(AUC_peak) (similar to 20%, p >= 0.016) and FMD/shear(AUC) (similar to 38%, p <= 0.038). Further analysis indicated that wall shear stress normalization under normal (fasting) conditions is already far from ideal (FMDv << 1), which (therefore) does not materially change with glucose loading. Our approach might be useful in intervention studies to detect intrinsic changes in shear stress normalization performance in conduit arteries.
引用
收藏
页数:19
相关论文
共 50 条
  • [11] Impact of controlling shear rate on flow-mediated dilation responses in the brachial artery of humans
    Pyke, KE
    Dwyer, EM
    Tschakovsky, ME
    JOURNAL OF APPLIED PHYSIOLOGY, 2004, 97 (02) : 499 - 508
  • [12] Facial cooling impairs brachial artery flow-mediated dilation
    Edwards, David G.
    Roy, Matthew S.
    Edwards, Jonathan W.
    Rose, William C.
    FASEB JOURNAL, 2008, 22
  • [13] Reliability of the Measurement of the Flow-mediated Dilation of the Brachial Artery by Ultrasonography
    Toledo, Juan Carlos Yugar
    Moreno Junior, Heitor
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2008, 91 (05) : 333 - 333
  • [14] Is Brachial Artery Flow-Mediated Dilation Associated with Negative Affect?
    Laura L. Schott
    Thomas W. Kamarck
    Karen A. Matthews
    Sarah E. Brockwell
    Kim Sutton-Tyrrell
    International Journal of Behavioral Medicine, 2009, 16 : 241 - 247
  • [15] INFLUENCE OF RESTING BRACHIAL ARTERY DIAMETER ON FLOW-MEDIATED DILATION
    Welsch, M.
    Allen, J.
    Tulley, R.
    Smith, S.
    Lefevre, M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S148 - S148
  • [16] INFLUENCE OF ARTERIAL DISTENSIBILITY ON BRACHIAL ARTERY FLOW-MEDIATED DILATION
    Allen, J.
    Parrino, P.
    Lefevre, M.
    Welsch, M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S148 - S148
  • [17] Is Brachial Artery Flow-Mediated Dilation Associated with Negative Affect?
    Schott, Laura L.
    Kamarck, Thomas W.
    Matthews, Karen A.
    Brockwell, Sarah E.
    Sutton-Tyrrell, Kim
    INTERNATIONAL JOURNAL OF BEHAVIORAL MEDICINE, 2009, 16 (03) : 241 - 247
  • [18] Impaired brachial artery endothelial flow-mediated dilation and orthostatic stress in hemodialysis patients
    Gallieni, M.
    Butti, A.
    Guazzi, M.
    Galassi, A.
    Cozzolino, M.
    Brancaccio, D.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (01): : 34 - 42
  • [19] The Effects of Exercise Training on Brachial Artery Flow-Mediated Dilation
    Early, Kate S.
    Stewart, Abigail
    Johannsen, Neil
    Lavie, Carl J.
    Thomas, Jerry R.
    Welsch, Michael
    JOURNAL OF CARDIOPULMONARY REHABILITATION AND PREVENTION, 2017, 37 (02) : 77 - 89
  • [20] Brachial Artery Flow-mediated Dilation Following Exercise with Augmented Oscillatory and Retrograde Shear Rate
    Johnson, Blair D.
    Mather, Kieren J.
    Newcomer, Sean C.
    Mickleborough, Timothy D.
    Wallace, Janet P.
    CARDIOVASCULAR ULTRASOUND, 2012, 10