Effective long-term left atrial pacing using regular screw-in leads implanted within the coronary sinus

被引:1
|
作者
Ouali, S
Anselme, F
Hidden, F
Savouré, A
Cribier, A
Saoudi, N
Frank, R
机构
[1] Rouen Univ Hosp, Dept Cardiol, Paris, France
[2] Pitie Salpitriere Hosp, Paris, France
[3] Princess Grace Hosp, Monaco, Monaco
来源
关键词
coronary sinus; pacing; follow-up;
D O I
10.1046/j.1460-9592.2003.t01-1-00283.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Passive-fixation leads positioned inside the coronary sinus (CS) have been found to be effective in LA pacing and sensing, but their use is limited by a high incidence of early and late dislodgment. Since anatomic studies have shown that the proximal part of the CS is surrounded by a relatively thick musculature, the feasibility, safety, and efficacy of acute and chronic coronary sinus pacing via regular screw-in leads positioned within the first centimeters of the CS were evaluated as compared to passive fixation leads. Thirty-three patients (21 men, age 62 +/- 10 years) underwent dual chamber pacemaker implantation with LA pacing obtained via passive-fixation leads (7 patients) or regular screw-in leads (26 patients). The former approach was prematurely abandoned because of a high rate of acute and late lead dislodgment (42%). The chronic pacing threshold was 1.7 +/- 1.0 V at 0.67-ms pulse width and 1.47 +/- 1.3V at 0.5-ms pulse width for passive- and active-fixation leads, respectively, In the CS active-fixation lead group, no postoperative pericardial effusion, CS lead dislodgment, nor diaphragmatic stimulation were observed. In this lost group, steroid eluting leads (14 patients) have a statistically lower pacing threshold than noneluting steroid leads (12 patients) (0.88 +/- 0.23 vs 2.29 +/- 1.68 V, P = 0.011) at long-term follow-up. The use of regular screw-in leads implanted within the CS allows effective and safe long-term LA pacing without risk of dislodgment.
引用
收藏
页码:1873 / 1877
页数:5
相关论文
共 50 条
  • [41] Long-term performance of coronary sinus leads used for cardiac resynchronization therapy: Polarity and aetiology analysis
    Bertaglia, E.
    LaRocca, V.
    Solimene, F.
    De Simone, A.
    Zerbi, F.
    Pascotto, P.
    Accogli, M.
    Iuliano, A.
    Marras, G.
    Stabile, G.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 : S30 - S31
  • [42] LONG-TERM EFFECT OF STEROID ELUTION ON THE ELECTRICAL PERFORMANCE OF CORONARY SINUS LEADS FOR CARDIAC RESYNCHRONIZATION THERAPY
    Bianchi, S.
    Rossi, P.
    Gasparini, M.
    Lunati, M.
    Boriani, G.
    Landolina, M.
    Padeletti, L.
    Santini, M.
    Canonaco, S.
    Valsecchi, S.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S143 - S143
  • [43] Long-term outcome of transvenous bipolar atrial leads implanted in children and young adults with congenital heart disease
    Silvetti, Massimo Stefano
    Drago, Fabrizio
    Rava, Lucilla
    EUROPACE, 2012, 14 (07): : 1002 - 1007
  • [44] PERMANENT PERVENOUS ATRIAL-PACING FROM CORONARY VEIN - LONG-TERM FOLLOW-UP
    MOSS, AJ
    RIVERS, RJ
    KRAMER, DH
    CIRCULATION, 1974, 49 (02) : 222 - 225
  • [45] Active-fixation Atrial Pacing Leads Following Amputation of Right Atrial Appendage: Long-term, Single-centre Study
    Huang, Dong
    Zhang, Qingyong
    Pan, Yesheng
    Liu, Mingya
    Wei, Meng
    Li, Jingbo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C176 - C176
  • [46] Long-term outcomes of left atrial appendage isolation using cryoballoon in persistent atrial fibrillation
    Yorgun, Hikmet
    Sener, Yusuf Ziya
    Tanese, Nikita
    Keresteci, Ahmet
    Sezenoz, Burak
    Coteli, Cem
    Ates, Ahmet Hakan
    Boveda, Serge
    Aytemir, Kudret
    EUROPACE, 2023, 25 (02): : 366 - 373
  • [47] Clinical value of left atrial appendage flow for prediction of long-term sinus rhythm maintenance in patients with nonvalvular atrial fibrillation
    Antonielli, E
    Pizzuti, A
    Pálinkás, A
    Tanga, M
    Gruber, N
    Michelassi, C
    Varga, A
    Bonzano, A
    Gandolfo, N
    Halmai, L
    Bassignana, A
    Imran, MB
    Delnevo, F
    Csanády, M
    Picano, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (09) : 1443 - 1449
  • [48] Prognostic value of left atrial appendage flow for assessment of long-term maintenance of sinus rhythm in patients with nonvalvular atrial fibrillation
    Picano, E
    Palinkas, A
    Nyuzo, B
    Gruber, N
    Varga, A
    Sicari, R
    Borthaiser, A
    Vass, A
    Csanady, M
    Alegret, JM
    EUROPEAN HEART JOURNAL, 2001, 22 : 544 - 544
  • [49] Clinical value of left atrial appendage flow for prediction of long-term sinus rhythm maintenance in patients with nonvalvular atrial fibrillation
    Pálinkás, A
    Antonielli, E
    Pizzuti, A
    Gruber, N
    Varga, A
    Bonzano, A
    Csanády, M
    Forster, T
    Picano, E
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2002, 34 (06) : A48 - A48
  • [50] Clinical value of left atrial appendage flow for prediction of long-term sinus rhythm maintenance in patients with nonvalvular atrial fibrillation
    Antonielli, E
    Pizzuti, A
    Pálinkás, A
    Tanga, M
    Gruber, N
    Varga, A
    Bonzano, A
    Gandolfo, N
    Coppolino, A
    Delnovo, F
    Csanády, M
    Baralis, G
    Forster, T
    Picano, E
    CIRCULATION, 2001, 104 (17) : 514 - 514