Combining contrast-enhanced ultrasound and blood cell analysis to improve diagnostic accuracy of plasma cell mastitis

被引:11
|
作者
Zheng, Yan [1 ]
Wang, Lin [2 ]
Han, Xiu [2 ]
Shen, Lin [3 ]
Ling, Chen [1 ]
Qian, Zhongping [1 ]
Zhu, Lin [1 ]
Dong, Fenglin [1 ]
Han, Qingzhen [2 ]
机构
[1] Soochow Univ, Affiliated Hosp 1, Suzhou 215000, Peoples R China
[2] Soochow Univ, Ctr Clin Lab, Dushu Lake Hosp, Suzhou 215000, Peoples R China
[3] Suzhou Municipal Hosp, Suzhou 215000, Peoples R China
关键词
Plasma cell mastitis; differential diagnosis; white blood cell count; contrast-enhanced ultrasound; breast carcinoma; inflammation; DIFFERENTIAL-DIAGNOSIS; BREAST;
D O I
10.1177/15353702211049361
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Plasma cell mastitis is a benign suppurative disease of the breast, lack of specific clinical manifestations, which is easy to be misdiagnosed and mistreated, often confused with mastitis, breast cancer (BC), and other diseases. Thus, we aimed to establish a combined model of promoting diagnostic accuracy of plasma cell mastitis by contrast-enhanced ultrasound (CEUS) patterns and routine blood cell analysis. Eighty-eight plasma cell mastitis, 91 breast cancer, and 152 other benign breast diseases' patients grouped according to pathological diagnosis underwent CEUS and blood cell analysis examination; 100 healthy female donors were involved. All the plasma cell mastitis and breast cancer patients presented hyperenhancement of CEUS breast lesions compared with others. The majority of plasma cell mastitis (65/88) showed perfusion defect of CEUS patterns with smooth edge (56/65) and multiple lesions (49/65); in contrast, fewer breast cancer patients (30/91) displayed perfusion defect. White blood cell count (WBC), neutrophils, and neutrophils/lymphocytes ratio of blood cell analysis in plasma cell mastitis patients increased significantly compared with other patients (P < 0.0001). Combining perfusion defect of CEUS patterns and WBC yielded an area under the receiver operating characteristic curve of 0.831, higher than single 0.720 and 0.774, respectively. The cut-off value of WBC (7.28 x 10(9)/L) helped remaining 65.2% (15/23) atypical cases to be correctly diagnosed as plasma cell mastitis, not misdiagnosed as breast cancer. In conclusion, CEUS presented a clear perfusion defect pattern of plasma cell mastitis lesion for the first time. A precise WBC by routine blood cell analysis test can assist CEUS examination in the differential diagnosis of plasma cell mastitis and breast cancer. It is a promised combination for laboratory diagnostic of PCM.
引用
收藏
页码:97 / 105
页数:9
相关论文
共 50 条
  • [31] Diagnostic Performance of Contrast-Enhanced Ultrasound (CEUS) and Contrast-Enhanced Endoscopic Ultrasound (ECEUS) for the Differentiation of Pancreatic Lesions: A Systematic Review and Meta-Analysis
    D'Onofrio, M.
    Biagioli, E.
    Gerardi, C.
    Canestrini, S.
    Rulli, E.
    Crosara, S.
    De Robertis, R.
    Floriani, I.
    ULTRASCHALL IN DER MEDIZIN, 2014, 35 (06): : 515 - 521
  • [32] Diagnostic efficacy of contrast-enhanced ultrasonography for small renal cell carcinoma
    Yuan, Xin-Chun
    Zhou, Ai-Yun
    Chen, Li
    Xiao, Fan
    Luo, Li-Yun
    Zhang, Cheng
    He, Jian-Xin
    Zhang, Yan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (02): : 3877 - 3884
  • [33] Visualization rate of contrast-enhanced ultrasound and conventional ultrasound for pseudocapsule of renal cell carcinoma
    Yang, Bin
    Fu, Ninghuan
    Ge, Jingping
    Shen, Dejuan
    Meng, Qingxing
    Liu, Ping
    SCIENTIFIC RESEARCH AND ESSAYS, 2010, 5 (14): : 1852 - 1855
  • [34] Diagnostic accuracy of contrast-enhanced ultrasound in the detection of small renal masses A protocol of systematic review and meta-analysis
    Wu, Jiang-feng
    Wu, Chao
    Wang, Yun-lai
    Wang, Zheng-ping
    MEDICINE, 2020, 99 (29) : E21262
  • [35] Diagnostic accuracy of contrast-enhanced ultrasound for microvascular invasion of hepatocellular carcinoma A protocol for systematic review and meta-analysis
    Chen, Yanli
    Qiao, Haiyan
    Lian, Zhaoan
    Li, Chunlin
    Xiang, Yi
    MEDICINE, 2022, 101 (15) : E29083
  • [36] Diagnostic accuracy of contrast-enhanced ultrasound to differentiate benign and malignant breast lesions: A systematic review and meta-analysis
    Wang, Jing
    Zhao, Rui
    Cheng, Jia
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 149
  • [37] The diagnostic accuracy of contrast-enhanced ultrasound for the differentiation of benign and malignant thyroid nodules A PRISMA compliant meta-analysis
    Liu, Qinghua
    Cheng, Jian
    Li, Jingjing
    Gao, Xiang
    Li, Hongbo
    MEDICINE, 2018, 97 (49)
  • [38] Diagnostic accuracy of contrast-enhanced computed tomography in assessing bone invasion in patients with oral squamous cell carcinoma
    Struckmeier, Ann-Kristin
    Buchbender, Mayte
    Agaimy, Abbas
    Kesting, Marco
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (06)
  • [39] Accuracy of Contrast-Enhanced Ultrasound in the Diagnosis of Bile Duct Obstruction
    Fontan, F. J. P.
    Reboredo, A. R.
    Siso, A. R.
    ULTRASOUND INTERNATIONAL OPEN, 2015, 1 (01) : E12 - E18
  • [40] Quantification of renal blood flow with contrast-enhanced ultrasound
    Wei, K
    Le, E
    Bin, JP
    Coggins, M
    Thorpe, J
    Kaul, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (04) : 1135 - 1140