An electrochemically preanodized screen-printed carbon electrode for achieving direct electron transfer to glucose oxidase

被引:33
|
作者
Yang, Ting-Hao [1 ]
Hung, Chi-Lung [1 ]
Ke, Jyh-Harng [1 ]
Zen, Jyh-Myng [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
glucose oxidase; direct electron transfer; preanodization; disposable; screen-printed carbon electrode;
D O I
10.1016/j.elecom.2008.05.020
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Here we report the unique property of a preanodized screen-printed carbon electrode (SPCE*) that can allow direct electron transfer (DET) reaction of glucose oxidase (GOx). The GOx can be immobilized in the composite of oxygen functionalities and edge plane sites generated during preanodization without additional cross-linking agents. The electron transfer rate of GOx is greatly enhanced to 4.38 s(-1) as a result of the conformational change of GOx in the microenvironment enabling the accessibility of active site for GOx to the electrode. The analytical versatility is further improved with the aid of Nafion film. As a consequence, the as-prepared electrode can be used as a glucose biosensor and the number of potential foreign species is then restricted by molecular size, permeation and/or (bio)chemical reaction. Most importantly, the disposable nature of the proposed electrode is expected to promote the DET-related researches. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1094 / 1097
页数:4
相关论文
共 50 条
  • [21] Direct electron transfer of glucose oxidase on carbon nanotubes
    Guiseppi-Elie, A
    Lei, CH
    Baughman, RH
    NANOTECHNOLOGY, 2002, 13 (05) : 559 - 564
  • [22] Activity enhancement of a screen-printed carbon electrode by modification with gold nanoparticles for glucose determination
    Masaru Iwamoto
    Shiho Tokonami
    Hiroshi Shiigi
    Tsutomu Nagaoka
    Research on Chemical Intermediates, 2009, 35
  • [23] Activity enhancement of a screen-printed carbon electrode by modification with gold nanoparticles for glucose determination
    Iwamoto, Masaru
    Tokonami, Shiho
    Shiigi, Hiroshi
    Nagaoka, Tsutomu
    RESEARCH ON CHEMICAL INTERMEDIATES, 2009, 35 (8-9) : 919 - 930
  • [24] Amperometric Determination of Glucose in White Grape and in Tablets as Ingredient by Screen-Printed Electrode Modified with Glucose Oxidase and Composite of Platinum and Multiwalled Carbon Nanotubes
    Guzsvany, Valeria
    Anojcic, Jasmina
    Vajdle, Olga
    Radulovic, Emil
    Madarasz, Daniel
    Konya, Zoltan
    Kalcher, Kurt
    FOOD ANALYTICAL METHODS, 2019, 12 (02) : 570 - 580
  • [25] Direct fabrication of catalytic metal nanoparticles onto the surface of a screen-printed carbon electrode
    Chikae, Miyuki
    Idegami, Koutarou
    Kerman, Kagan
    Nagatani, Naoki
    Ishikawa, Mitsuyoshi
    Takamura, Yuzuru
    Tamiya, Eiichi
    ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (08) : 1375 - 1380
  • [26] Amperometric Determination of Glucose in White Grape and in Tablets as Ingredient by Screen-Printed Electrode Modified with Glucose Oxidase and Composite of Platinum and Multiwalled Carbon Nanotubes
    Valéria Guzsvány
    Jasmina Anojčić
    Olga Vajdle
    Emil Radulović
    Dániel Madarász
    Zoltán Kónya
    Kurt Kalcher
    Food Analytical Methods, 2019, 12 : 570 - 580
  • [27] Stabilization of glucose-oxidase in the graphene paste for screen-printed glucose biosensor
    Peplowski, Andrzej
    Janczak, Daniel
    Jakubowska, Malgorzata
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2015, 2015, 9662
  • [28] Electrochemically Reduced Graphene Oxide as Screen-printed Electrode Modifier for Fenamiphos Determination
    Gevaerd, A.
    Watanabe, E. Y.
    Fernandes, K.
    Papi, M. A. P.
    Banks, C. E.
    Bergamini, M. F.
    Marcolino-Junior, L. H.
    ELECTROANALYSIS, 2020, 32 (08) : 1689 - 1695
  • [29] Amperometric Determination of Glucose with FeO and Glucose Oxidase Bulk-Modified Screen-Printed Carbon Ink Biosensor
    Turkusic, E.
    Begic, S.
    Kahrovic, E.
    Kalcher, K.
    HEALTHMED, 2011, 5 (05): : 1117 - 1122
  • [30] Electron transfer between an electrochemically deposited glucose oxidase Cu[II] complex and an electrode
    Haruyama, T
    Aizawa, M
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (09): : 1015 - 1022