Sol-gel-based SPME and GC-MS for trace determination of geosmin in water and apple juice samples

被引:16
|
作者
Bagheri, Habib [1 ]
Aghakhani, Ali [1 ]
Es-haghi, Ali [1 ]
机构
[1] Sharif Univ Technol, Dept Chem, Tehran, Iran
关键词
gas chromatography; solid-phase microextraction; sol-gel technology; apple juice; geosmin;
D O I
10.1365/s10337-007-0405-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A headspace solid-phase microextraction (HS-SPME) method was developed for the trace determination of geosmin in water and apple juice samples. A poly(dimethylsiloxane) (PDMS) fiber was synthesized as coated fiber using sol-gel methodology. After performing the extraction in the headspace, the fiber was introduced directly into the injection port of a gas chromatography-mass spectrometry (GC-MS) using electron impact (EI) ionization mode. One-at-the-time optimization strategy was applied to investigate and optimize important extraction parameters such as extraction temperature and time, ionic strength, headspace volume, and desorption temperature and time. The analytical data exhibited an RSD of 2-15%, a linear calibration range of 1-1,000 ng L-1, and a detection limit of 0.30 ng L-1 using selected ion monitoring (SIM) mode. The proposed method was successfully applied to the extraction and determination of geosmin in the spiked real water and apple juice samples and a relative recovery of 95-102% were achieved. The developed method offers the advantage of being simple to use, with shorter analysis times, lower cost of equipment, very little matrix effect, and high relative recovery in comparison to conventional methods of analysis.
引用
收藏
页码:779 / 783
页数:5
相关论文
共 50 条
  • [21] Determination of the acaricide fenbutatin oxide in water samples by automated headspace-SPME-GC/MS
    Devos, C
    Moens, L
    Sandra, P
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (07) : 665 - 668
  • [22] A Low-Cost Approach Using Diatomaceous Earth Biosorbent as Alternative SPME Coating for the Determination of PAHs in Water Samples by GC-MS
    Reinert, Naysla Paulo
    Vieira, Camila M. S.
    da Silveira, Cristian Berto
    Budziak, Dilma
    Carasek, Eduardo
    SEPARATIONS, 2018, 5 (04)
  • [23] Total p-chlorophenol determination in urine samples of subjects exposed to chlorobenzene, using SPME and GC-MS
    Guidotti, M
    Ravaioli, G
    Vitali, M
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1999, 22 (07): : 427 - 428
  • [24] MICROEXTRACTION IN PACKED SYRINGE COUPLED WITH GC-MS FOR THE DETERMINATION OF PESTICIDES IN ENVIRONMENTAL WATER SAMPLES
    Szarka, Agnesa
    Hrouzkova, Svetlana
    Deszatova, Ti Mea
    Zichova, Silvia
    FRESENIUS ENVIRONMENTAL BULLETIN, 2017, 26 (04): : 2664 - 2671
  • [25] A capsule phase microextraction protocol combined with GC-MS/MS for the determination of polychlorinated biphenyls in water samples
    Manousi, Natalia
    Efstratiadis, Georgios
    Kabir, Abuzar
    Rosenberg, Erwin
    Zachariadis, George
    Kalogiouri, Natasa P.
    MICROCHEMICAL JOURNAL, 2024, 206
  • [26] Trace-level determination of 1,4-dioxane in water by isotopic dilution GC and GC-MS
    Draper, WM
    Dhoot, JS
    Remoy, JW
    Perera, SK
    ANALYST, 2000, 125 (08) : 1403 - 1408
  • [27] Application of GC-MS with a SPME and thermal desorption technique for determination of dimethylamine and trimethylamine in gaseous samples for medical diagnostic purposes
    Wzorek, Beata
    Mochalski, Pawel
    Sliwka, Ireneusz
    Amann, Anton
    JOURNAL OF BREATH RESEARCH, 2010, 4 (02)
  • [28] Experimental design of switchable solvent–based liquid phase microextraction for the accurate determination of etrimfos from water and food samples at trace levels by GC-MS
    Merve Fırat
    Dotse Selali Chormey
    Sezgin Bakırdere
    Fatma Turak
    Environmental Monitoring and Assessment, 2019, 191
  • [29] Determination of Seven Odorants in Purified Water Among Worldwide Brands by HS-SPME Coupled to GC-MS
    Peng, Shifu
    Ding, Zhen
    Zhao, Lei
    Fei, Juan
    Xuan, Zhoubin
    Huang, Chenxi
    Chen, Xiaodong
    CHROMATOGRAPHIA, 2014, 77 (9-10) : 729 - 735
  • [30] Comparison of SPME to liquid-liquid extraction for the GC-MS determination of triclosan in water contaminated with OWC's
    Geary, Robert E.
    Waratuke, Stephen