Resurfacing arthroplasty versus silicone arthroplasty for proximal interphalangeal joint osteoarthritis

被引:71
|
作者
Branam, Barton R.
Tuttle, Harrison G.
Stern, Peter J.
Levin, Linda
机构
[1] Univ Cincinnati, Coll Med, Dept Orthopaed Surg, Cincinnati, OH USA
[2] Univ Cincinnati, Coll Med, Ctr Biostat Serv, Cincinnati, OH USA
[3] Raleigh Orthopaed Clin, Raleigh, NC USA
来源
关键词
arthroplasty; PIPJ; proximal interphalangeal joint; pyrolytic carbon; silicone;
D O I
10.1016/j.jhsa.2007.04.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the outcomes of silicone proximal interphalangeal joint (PIPJ) arthroplasties to pyrolytic carbon implants in patients with osteoarthritis. Methods: This study is a retrospective review of 41 arthroplasties in 22 patients with severe PIPJ osteoarthritis performed by a single surgeon. There were 13 patients and 22 joints in the silicone group with an average follow-up of 45 months. There were 9 patients and 19 joints in the pyrolytic carbon group with an average follow-up of 19 months. Clinical assessment included range of motion, grip strength, and deformity. Radiographs were evaluated for alignment, subsidence, and implant fracture. Patients filled out a subjective questionnaire with respect to pain, appearance of the finger, and satisfaction. Complications were recorded. Results: In the silicone group, the average preoperative PIPJ range of motion (ROM) was 11 degrees/64 degrees (extension/flexion) and the average postoperative ROM was 13 degrees/62 degrees. In the pyrolytic carbon group, the average preoperative PIN ROM was 11 degrees/63 degrees and the average postoperative ROM was 13 degrees/66 degrees. Eleven of 20 joints in the silicone group and 4 of 19 joints in the pyrolytic carbon group had a coronal plane deformity as defined by angulation of the PIPJ >= 0 degrees. The average coronal plane deformity was 12 degrees in the silicone group and 12 degrees in the pyrolytic carbon group. The difference was statistically significant. In the silicone group, 3 of 22 joints required additional surgery. Two implants in one patient were removed and the PIPJ fused, and one implant was permanently removed for sepsis. In the pyrolytic carbon group, 8 of 19 joints squeaked, and there were 2 early postoperative dislocations and 2 implants with radiographic loosening. To date, there has been no revision surgery. Both groups had good pain relief. Patients were generally satisfied with the appearance of their joints in the pyrolytic carbon arm; however, satisfaction with appearance was variable in the silicone group. Nine of 13 patients in the silicone group and 6 of 7 patients in the pyrolytic carbon group would have the procedure again. Conclusions: Both implants provide excellent pain relief and comparable postoperative ROM. Complications were implant specific. The results of this series show promise for the pyrolytic carbon PIPJ resurfacing arthroplasty but did not clearly demonstrate superiority compared with the silicone implant.
引用
收藏
页码:775 / 788
页数:14
相关论文
共 50 条
  • [21] Proximal interphalangeal joint prosthetic arthroplasty
    Matter-Parrat, V.
    HAND SURGERY & REHABILITATION, 2023, 42 (03): : 184 - 193
  • [22] DIGITAL ARTHROPLASTY OF THE PROXIMAL INTERPHALANGEAL JOINT
    CARROLL, RE
    TABER, TH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (05): : 912 - 920
  • [23] Proximal Interphalangeal Joint Prosthetic Arthroplasty
    Sweets, Thomas M.
    Stern, Peter J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (07): : 1190 - 1193
  • [24] Proximal Interphalangeal Joint Arthroplasty for Fracture
    Raducha, Jeremy E.
    Weiss, Arnold-Peter C.
    HAND CLINICS, 2023, 39 (04) : 575 - 586
  • [25] Volar plate arthroplasty for osteoarthritis of the proximal interphalangeal joint: A preliminary report
    Burton, RI
    Campolattaro, RM
    Ronchetti, PJ
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (06): : 1065 - 1072
  • [26] Prosthetic Arthroplasty Versus Arthrodesis for Osteoarthritis and Posttraumatic Arthritis of the Index Finger Proximal Interphalangeal Joint
    Vitale, Mark A.
    Fruth, Kristin M.
    Rizzo, Marco
    Moran, Steven L.
    Kakar, Sanjeev
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (10): : 1937 - 1948
  • [27] Revision Arthroplasty for Failed Silicone Proximal Interphalangeal Joint Arthroplasty: Indications and 8-Year Results
    Herren, Daniel B.
    Keuchel, Tina
    Marks, Miriam
    Schindele, Stephan
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (03): : 462 - 466
  • [28] SILICONE INTERPOSITIONAL ARTHROPLASTY OF THE DISTAL INTERPHALANGEAL JOINT
    ZIMMERMAN, NB
    SUHEY, PV
    CLARK, GL
    WILGIS, EFS
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14A (05): : 882 - 887
  • [29] Finger proximal interphalangeal joint gap arthroplasty
    Abdelshaheed M.E.
    Khalil A.A.-G.
    Younis R.A.
    Moustafa A.M.B.E.-D.
    Shehabeldin S.A.M.
    European Journal of Plastic Surgery, 2017, 40 (2) : 117 - 122
  • [30] Surgical approaches for proximal interphalangeal joint arthroplasty
    Renfree, K. J.