Progress toward "optical beam induced noise" measurement set-up

被引:0
|
作者
Routoure, JM [1 ]
Méchin, L [1 ]
Flament, S [1 ]
机构
[1] Univ Caen, ENSICAEN, CNRS UMR 6072, GREYC, F-14050 Caen, France
来源
Noise and Fluctuations | 2005年 / 780卷
关键词
noise; defects; optical beam induced;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The paper presents an experimental set-up dedicated to noise measurements of samples under laser spot illumination. The laser is scanned on the surface which locally heats. The noise level is recorded at each positions. The final purpose of the system is to detect spatial inhomogeneities in the microscopic noise sources of resistive samples (La0.7Sr0.3MnO3 for example).
引用
收藏
页码:681 / 684
页数:4
相关论文
共 50 条
  • [31] Improved Set-Up for the Ytterbium Optical Clock at INRIM
    Pizzocaro, Marco
    Bregolin, Filippo
    Calonico, Davide
    Costanzo, Giovanni Antonio
    Levi, Filippo
    Lorini, Luca
    2013 JOINT EUROPEAN FREQUENCY AND TIME FORUM & INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (EFTF/IFC), 2013, : 379 - +
  • [32] Study of Interference Noise in Multi-Kinect Set-up
    Mallick, Tanwi
    Das, Partha Pratim
    Majumdar, Arun Kumar
    PROCEEDINGS OF THE 2014 9TH INTERNATIONAL CONFERENCE ON COMPUTER VISION THEORY AND APPLICATIONS (VISAPP), VOL 1, 2014, : 173 - 178
  • [33] Detection of optical photons with the Timepix in an HPD set-up
    Gebert, Ulrike
    Ruegheimer, Tilman K.
    Michel, Thilo
    Anton, Gisela
    Seguinot, Jacques
    Joram, Christian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 288 - 290
  • [34] Student laboratory set-up for optical fiber testing
    Gajda, J
    Niesterowicz, A
    TECHNOLOGY AND APPLICATIONS OF LIGHT GUIDES, 1997, 3189 : 153 - 157
  • [35] Mathematical model of the electronuclear set-up on the beam of JINR synchrotron
    Barashenkov, VS
    Kumawat, H
    Lobanova, VA
    Kumar, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 217 (02): : 352 - 360
  • [36] INFLUENCE OF BODY-TEMPERATURE ON THE SET-UP AND RECOVERY OF NOISE-INDUCED COCHLEA DAMAGE
    BERNDT, H
    WAGNER, H
    ARCHIVES OF OTO-RHINO-LARYNGOLOGY-ARCHIV FUR OHREN-NASEN-UND KEHLKOPFHEILKUNDE, 1981, 232 (02): : 199 - 202
  • [37] A highly flexible measurement set-up for the LF noise up-conversion and phase-noise performance characterization of microwave electron devices
    Florian, Corrado
    Traverso, Pier Andrea
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 1675 - 1680
  • [38] FAST BEAM CHAMBERS OF THE SET-UP ISTRA-M
    GUSHCHIN, EM
    KOMISSAROV, EV
    MUSIENKO, YV
    POBLAGUEV, AA
    SERDYUK, VZ
    ZALIKHANOV, BZ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 351 (2-3): : 345 - 348
  • [39] Designing an optical set-up of differential laser triangulation for oil film thickness measurement on water
    Ge Baozhen
    Sun Jingbin
    Liu Pengcheng
    Lu Qieni
    Wu Di
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (01):
  • [40] The external beam microprobe facility in Florence:: Set-up and performance
    Massi, M
    Giuntini, L
    Chiari, M
    Gelli, N
    Mandò, PA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 190 : 276 - 282