On the Incorrect Statistical Calculations of the Kinetica Software Package in Imbalanced Designs

被引:0
|
作者
Morales-Alcelay, S. [1 ]
de la Torre de Alvarado, J. M. [1 ]
Garcia-Arieta, A. [1 ]
机构
[1] Spanish Agcy Med & Hlth Care Prod, Madrid 28022, Spain
来源
AAPS JOURNAL | 2015年 / 17卷 / 04期
关键词
bioequivalence; crossover; parallel; statistical analysis;
D O I
10.1208/s12248-015-9749-1
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This regulatory note supports the previous findings that suggest that the software package Kinetica, up to version 5.0.10, provides incorrect results for the 90% confidence intervals for the ratio test/reference where the groups are imbalanced in 2x2 crossover designs and parallel designs. The incorrect calculation results from using the simplified formula that is shown as an example in the Canadian guideline for a balanced dataset, but which provides an erroneous point estimate and confidence interval width in cases of imbalanced designs. Importantly, this software is rarely used for regulatory submissions in the European Union according to the search conducted in the Spanish Agency for Medicines and Health Care Products. According to our data, the error is minor if the imbalance between groups is small. However, the error may be relevant if the sample size is small and the imbalance is large. Therefore, bioequivalence studies should be reanalyzed by regulatory agencies to confirm the submitted results.
引用
收藏
页码:1033 / 1034
页数:2
相关论文
共 50 条
  • [31] A NON-TECHNICAL USERS REVIEW OF COMPUTER SOFTWARE - THE CRUNCH STATISTICAL PACKAGE
    COUNELIS, JS
    SYSTEMS RESEARCH, 1988, 5 (03): : 273 - 275
  • [32] ON THE USE OF A STATISTICAL SOFTWARE PACKAGE FOR LOAD PREDICTIONS FOR DEVELOPING POWER-SYSTEMS
    EKWUE, AO
    SHORT, MJ
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1990, 12 (01) : 37 - 42
  • [33] Formulating of recipe for fireproof coatings via DOE based on statistical software package
    Hu, Jian
    Bin Wang, Zhi
    Zhou, Wen
    Dou, Yan Rong
    INFORMATION TECHNOLOGY AND COMPUTER APPLICATION ENGINEERING, 2014, : 519 - 522
  • [34] Statistical Power Calculations for Mixed Pharmacokinetic Study Designs Using a Population Approach
    Kloprogge, Frank
    Simpson, Julie A.
    Day, Nicholas P. J.
    White, Nicholas J.
    Tarning, Joel
    AAPS JOURNAL, 2014, 16 (05): : 1110 - 1118
  • [35] Statistical Power Calculations for Mixed Pharmacokinetic Study Designs Using a Population Approach
    Eke, Ahizechukwu C.
    OBSTETRICS AND GYNECOLOGY, 2018, 132 (04): : 1060 - 1060
  • [36] Statistical Power Calculations for Mixed Pharmacokinetic Study Designs Using a Population Approach
    Frank Kloprogge
    Julie A. Simpson
    Nicholas P. J. Day
    Nicholas J. White
    Joel Tarning
    The AAPS Journal, 2014, 16 : 1110 - 1118
  • [37] Technical note: The libRadtran software package for radiative transfer calculations - description and examples of use
    Mayer, B
    Kylling, A
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2005, 5 : 1855 - 1877
  • [38] Development of a software package for solid-angle calculations using the Monte Carlo method
    Zhang, Jie
    Chen, Xiulian
    Zhang, Changsheng
    Li, Gang
    Xu, Jiayun
    Sun, Guangai
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 736 : 40 - 45
  • [39] RISMiCal: A software package to perform fast RISM/3D-RISM calculations
    Maruyama, Yutaka
    Yoshida, Norio
    JOURNAL OF COMPUTATIONAL CHEMISTRY, 2024, 45 (17) : 1470 - 1482
  • [40] Software tools for implementing simulation studies in adaptive seamless designs: introducing R package ASD