Comparison between the two-step and the three-step algorithms for the detection of toxigenic Clostridium difficile

被引:5
|
作者
Qutub, M. O. [1 ]
Albaz, N.
Hawken, P.
Anoos, A.
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Pathol, Jeddah 21499, Saudi Arabia
关键词
Antibiotic-associated diarrhoea; Clostridium difficile; EIAs; glutamate dehydrogenase; TOX-A/B EIA; ENZYME-IMMUNOASSAY; TOXIN-A; DIAGNOSIS; TESTS; ASSAY; ANTIGEN; PANEL;
D O I
10.4103/0255-0857.83916
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Purpose: To evaluate usefulness of applying either the two-step algorithm (Ag-EIAs and CCNA) or the three-step algorithm (all three assays) for better confirmation of toxigenic Clostridium difficile. The antigen enzyme immunoassays (Ag-EIAs) can accurately identify the glutamate dehydrogenase antigen of toxigenic and nontoxigenic Clostridium difficile. Therefore, it is used in combination with a toxin-detecting assay [cell line culture neutralization assay (CCNA), or the enzyme immunoassays for toxins A and B (TOX-A/BII EIA)] to provide specific evidence of Clostridium difficile-associated diarrhoea. Materials and Methods: A total of 151 nonformed stool specimens were tested by Ag-EIAs, TOX-A/BII EIA, and CCNA. All tests were performed according to the manufacturer's instructions and the results of Ag-EIAs and TOX-A/BII EIA were read using a spectrophotometer at a wavelength of 450 nm. Results: A total of 61 (40.7%), 38 (25.3%), and 52 (34.7%) specimens tested positive with Ag-EIA, TOX-A/BII EIA, and CCNA, respectively. Overall, the sensitivity, specificity, negative predictive value, and positive predictive value for Ag-EIA were 94%, 87%, 96.6%, and 80.3%, respectively. Whereas for TOX-A/BII EIA, the sensitivity, specificity, negative predictive value, and positive predictive value were 73.1%, 100%, 87.5%, and 100%, respectively. With the two-step algorithm, all 61 Ag-EIAs-positive cases required 2 days for confirmation. With the three-step algorithm, 37 (60.7%) cases were reported immediately, and the remaining 24 (39.3%) required further testing by CCNA. By applying the two-step algorithm, the workload and cost could be reduced by 28.2% compared with the three-step algorithm. Conclusions: The two-step algorithm is the most practical for accurately detecting toxigenic Clostridium difficile, but it is time-consuming.
引用
收藏
页码:293 / 296
页数:4
相关论文
共 50 条
  • [31] A comparative study of two-step and three-step methods for coating organometallic lead halide perovskite thin films
    Sagar A. More
    Rajendra Halor
    Shaikh Raees
    Sanjay S. Ghosh
    Journal of Materials Science: Materials in Electronics, 2020, 31 : 17995 - 18003
  • [32] A comparative study of two-step and three-step methods for coating organometallic lead halide perovskite thin films
    More, Sagar A.
    Halor, Rajendra
    Raees, Shaikh
    Ghosh, Sanjay S.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2020, 31 (20) : 17995 - 18003
  • [33] A review for three-step phase-shifting algorithms
    Zhang, Yu
    Liu, Bao
    Zhou, Pengyu
    Wang, Haitao
    OPTICS AND LASERS IN ENGINEERING, 2025, 186
  • [34] Harmonic analysis on two and three-step nilmanifolds
    Ghorbel, Amira
    Hamrouni, Hatem
    Ludwig, Jean
    BULLETIN DES SCIENCES MATHEMATIQUES, 2014, 138 (08): : 887 - 911
  • [35] Tests for equality of mean vectors and simultaneous confidence intervals with two-step or three-step monotone missing data patterns
    Yagi, Ayaka
    Seo, Takashi
    American Journal of Mathematical and Management Sciences, 2015, 34 (03) : 213 - 233
  • [36] Using an isomorphic problem pair to learn introductory physics: Transferring from a two-step problem to a three-step problem
    Lin, Shih-Yin
    Singh, Chandralekha
    PHYSICAL REVIEW SPECIAL TOPICS-PHYSICS EDUCATION RESEARCH, 2013, 9 (02):
  • [37] COMPARISON OF DIFFERENT COORDINATION ALGORITHMS IN THE MODIFIED TWO-STEP TECHNIQUE.
    Filip, F.G.
    Donciulescu, D.A.
    Muratcea, M.
    Advances in modelling & simulation, 1985, 4 (01): : 41 - 52
  • [38] Comparison between the "one-step" and "two-step" catalytic pyrolysis of pine bark
    Gungor, Ahmet
    Onenc, Sermin
    Ucar, Suat
    Yanik, Jale
    JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 2012, 97 : 39 - 48
  • [39] Comparison of two-step and one-step motion compensation algorithms for airborne synthetic aperture radar
    Yang, Mingdong
    Zhu, Daiyin
    Song, Wei
    ELECTRONICS LETTERS, 2015, 51 (14) : 1108 - 1109
  • [40] PROSPECTIVE EVALUATION OF A NOVEL TWO-STEP PROTOCOL FOR SCREENING OF CLOSTRIDIUM DIFFICILE INFECTION IN HOSPITALIZED ADULT PATIENTS
    Issarachaikul, Ratima
    Khantipong, Mayuree
    Sawatpanich, Ajcharaporn
    Suankratay, Chusana
    SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2015, 46 (06) : 1037 - 1048