Respirometric measurement of kinetic parameters: effect of activated sludge floc size

被引:43
|
作者
Chu, KH
van Veldhulzen, HM
van Loosdrecht, MCM
机构
[1] Univ Canterbury, Dept Chem & Proc Engn, Christchurch 1, New Zealand
[2] Delft Univ Technol, Kluyver Lab Biotechnol, NL-2628 BC Delft, Netherlands
关键词
activated sludge; floc size; kinetic parameter; mixing intensity; respirometry;
D O I
10.2166/wst.2003.0453
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The variation of activated sludge floc size with the mixing intensity of a mechanically stirred respirometer, expressed in terms of the mean energy dissipation rate, was characterized using a photometric dispersion analyzer. The floc size decreased rapidly when the energy dissipation rate was increased from 1.33 x 10(-3) to 2.68 x 10(-3) W/kg. Experiments were performed to investigate the effect of floc size on the oxygen saturation coefficient measured under the condition of acetate oxidation. The respirometric data were interpreted by considering only the kinetics of biochemical reactions. The variation of the oxygen saturation coefficient with mixing intensity was found to correlate with the variation of floc size with mixing intensity. The oxygen saturation coefficient was found to decrease from 0.23 to 0.08 mg/L when the mean energy dissipation rate was increased from 1.33 x 10(-3) to 2.68 x 10(-3) W/kg. The dependence of the oxygen saturation coefficient on floc size or mixing intensity suggests the presence of mass transfer resistances in large flocs.
引用
收藏
页码:61 / 68
页数:8
相关论文
共 50 条
  • [21] Unified basis for the respirometric evaluation of inhibition for activated sludge
    Insel, Guclu
    Karahan, Ozlen
    Özdemir, Seda
    Pala, Llke
    Katipoǧlu, Tugce
    Cokgör, Emine
    Orhon, Derin
    Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, 2006, 41 (09): : 1763 - 1780
  • [22] Comparison of dewaterability and floc structure of synthetic sludge with activated sludge
    Chu, CP
    Lee, DJ
    ENVIRONMENTAL TECHNOLOGY, 2005, 26 (01) : 1 - 10
  • [23] Bacterial composition of activated sludge - importance for floc and sludge properties
    Nielsen, PH
    Thomsen, TR
    Nielsen, JL
    WATER SCIENCE AND TECHNOLOGY, 2004, 49 (10) : 51 - 58
  • [24] DETERMINATION OF KINETIC AND STOICHIOMETRIC PARAMETERS OF ACTIVATED SLUDGE MODELS
    Liwarska-Bizukojc, Ewa
    Ledakowicz, Stanislaw
    ENVIRONMENT PROTECTION ENGINEERING, 2011, 37 (03): : 73 - 83
  • [25] Influence of selected antibiotics on respirometric activity of activated sludge
    Varjuova, Dora
    Szabova, Petra
    Bodik, Igor
    ACTA CHIMICA SLOVACA, 2021, 14 (01): : 86 - 96
  • [26] Bacterial composition of activated sludge - importance for floc and sludge properties
    Nielsen, PH
    Thomsen, TR
    Nielsen, JL
    WASTEWATER SLUDGE AS A RESOURCE, 2003, : 71 - 78
  • [27] FLOC SIZE, FILAMENT LENGTH AND SETTLING PROPERTIES OF PROTOTYPE ACTIVATED-SLUDGE PLANTS
    SEZGIN, M
    JENKINS, D
    PALM, JC
    PROGRESS IN WATER TECHNOLOGY, 1980, 12 (03): : 171 - 182
  • [28] FLOC SIZE, FILAMENT LENGTH AND SETTLING PROPERTIES OF PROTOTYPE ACTIVATED-SLUDGE PLANTS
    CLARK, EI
    SEZGIN, M
    JENKINS, D
    PALM, JC
    PROGRESS IN WATER TECHNOLOGY, 1980, 12 (05): : 702 - 704
  • [29] Respirometric analyses for management of activated sludge treatment plants
    Weiss, B
    Roche, N
    Potier, O
    Pons, MN
    Gauthier, S
    Prost, C
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1998, 25 (02) : 353 - 359
  • [30] FLOC BREAKUP IN ACTIVATED-SLUDGE PLANTS
    DAS, D
    KEINATH, TM
    PARKER, DS
    WAHLBERG, EJ
    WATER ENVIRONMENT RESEARCH, 1993, 65 (02) : 138 - 145