Purpose. To test the influence of maternal age and parity on placental volume and uterine spiral vasculature volume, their mean gray value, and 3-dimensional power Doppler (3DPD) indices in normal pregnancy. Methods. Women with a gestational age of 14-25 weeks were included in the study. Exclusion criteria included posterior placenta, structural or chromosomal anomaly, pregnancy complications, and unknown pregnancy outcome. 3D sonograms of the placenta and uterine spiral vasculature were obtained, Virtual Organ Computer-aided AnaLysis imaging software was used to calculate the volumes, mean gray value, and 3DPD indices. Results. The study included 199 women, the majority of whom were Filipino, Japanese, or part Hawaiian. The placental volume, uterine spiral vasculature volume, mean gray value, and 3DPD indices were similar in all women regardless of maternal age. However, uterine spiral vasculature volume was significantly larger in women younger than 25 years, compared with women 35 years of age and older. Parity influenced all placental 3DPD indices, whereas placental volume, uterine spiral vasculature volume, mean gray value, and 3DPD indices remained unaffected. Conclusion. Maternal age influenced uterine spiral vasculature volume, whereas parity influenced all placental 3DPD indices. (C) 2008 Wiley Periodicals, Inc.
引用
收藏
页码:391 / 396
页数:6
相关论文
共 50 条
  • [41] Placental antioxidant systems -maternal age influence
    Gaman, L.
    Lixandru, D.
    Gilca, M.
    Gheorgiu, I.
    Muscurel, C.
    Panait, E.
    Horhoianu, I.
    Atanasiu, V.
    Stoian, I.
    FREE RADICAL BIOLOGY AND MEDICINE, 2013, 65 : S51 - S51
  • [42] A three-dimensional morphological reconstruction of uterine leiomyoma pseudocapsule vasculature by the Allen-Cahn mathematical model
    Malvasi, Antonio
    Tinelli, Andrea
    Rahimi, Siavash
    D'Agnese, Giampaolo
    Rotoni, Cristiana
    Dell'Edera, Domenico
    Tsin, Daniel A.
    Cavallotti, Carlo
    BIOMEDICINE & PHARMACOTHERAPY, 2011, 65 (05) : 359 - 363
  • [43] Three-dimensional transvaginal ultrasound and two-dimensional transvaginal contrast sonography for the assessment of uterine anatomy: a comparison with hysterosalpingography
    La Torre, R
    De Felice, C
    Coacci, F
    Fusaro, P
    Curto, C
    Viggiani, A
    Cosmi, EV
    LABOR AND DELIVERY, 1998, : 481 - 484
  • [44] Two-dimensional and three-dimensional sonography of conjoined twins
    Bonilla-Musoles, F
    Machado, LE
    Osborne, NG
    Blanes, J
    Bonilla, F
    Raga, F
    Machado, F
    JOURNAL OF CLINICAL ULTRASOUND, 2002, 30 (02) : 68 - 75
  • [45] Influence of nonexcitable cells on spiral breakup in two-dimensional and three-dimensional excitable media
    ten Tusscher, KHWJ
    Panfilov, AV
    PHYSICAL REVIEW E, 2003, 68 (06):
  • [46] Three-Dimensional Interferometric Imaging at Terahertz Frequencies Using Three-Dimensional Spiral Array
    Goltsman, Alex
    Zaghloul, Amir I.
    2008 33RD INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES, VOLS 1 AND 2, 2008, : 847 - 848
  • [47] Three-dimensional hysterosonographic evaluation of the normal endometrium: Comparison with transvaginal sonography and three-dimensional ultrasound
    BonillaMusoles, F
    Raga, F
    Blanes, J
    Osborne, NG
    Coelho, F
    JOURNAL OF GYNECOLOGIC SURGERY, 1997, 13 (03) : 101 - 107
  • [48] Reproducibility of Placental Volume and Vasculature Indices Obtained by 3-Dimensional Power Doppler Sonography
    Huster, Kristina M.
    Haas, Kimberly
    Schoenborn, Jean
    McVean, Dominique
    Odibo, Anthony O.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (06) : 911 - 916
  • [49] Does prior cesarean delivery and maternal parity influence placental migration?
    Predanic, M
    Perni, SC
    Jean-Pierre, C
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (06) : S182 - S182
  • [50] The influence of mare age and parity on placental and fetal development in the mare
    Wilsher, S
    Allen, WR
    PFERDEHEILKUNDE, 2001, 17 (06): : 694 - 694