A different approach to orbital blow out fractures: Microscope-assisted reconstruction of the orbital floor

被引:4
|
作者
Park., Albert H. [1 ]
Diaz, Jason A. [1 ]
机构
[1] Univ Utah, Sch Med, Dept Surg, Div Otolaryngol Head & Neck Surg, Salt Lake City, UT 84132 USA
关键词
orbital floor fracture; pediatric; microscope;
D O I
10.1016/j.ijporl.2008.01.016
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
To describe a different surgical approach to treat pediatric orbital floor fractures. We report the case of a 14-year-old boy who underwent a microscope-assisted repair of his orbital floor fracture 6 weeks after his injury. The microscope provided excellent visualization of the entire orbital floor defect and facilitated placement of a polyethylene implant. The repair was achieved without complications, and follow-up examinations demonstrated improvement in patient's enophthalmos and diplopia. We noted significant advantages with a microscope-assisted repair over an endoscopic technique for this condition. The operating microscope allows for two-handed surgery, does not require withdraw of the endoscope for cleaning, and provides depth of field. A larger patient population and longer follow-up are needed to better assess the clinical efficacy of this technique. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:707 / 710
页数:4
相关论文
共 50 条
  • [21] Management of orbital blow-out fractures
    Bernardini, Francesco P.
    de Conciliis, Carlo
    EXPERT REVIEW OF OPHTHALMOLOGY, 2008, 3 (03) : 269 - 272
  • [22] Does diplopia persist after blow-out fractures of the orbital floor in children?
    Cope, MR
    Moos, KF
    Speculand, B
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1999, 37 (01): : 46 - 51
  • [23] Porous Polyethylene Implants in Orbital Blow-Out Fractures and Enophthalmos Reconstruction
    Xu, Jia-jie
    Teng, Li
    Jin, Xiao-lei
    Ji, Ying
    Lu, Jian-jian
    Zhang, Bo
    JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (03) : 918 - 920
  • [24] The custom-made titanium orbital floor prosthesis in reconstruction for orbital floor fractures
    Hughes, CW
    Page, K
    Bibb, R
    Taylor, J
    Revington, P
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2003, 41 (01): : 50 - 53
  • [25] Computer guided calvarial bone grafting for reconstruction of orbital floor blow out fracture
    Ahmed, Mamdouh
    Ali, Sherif
    Elhadidy, Mona Samy
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2022, 18 (05):
  • [26] Reconstruction of orbital floor fractures with maxillary bone
    Lee, HH
    Alcaraz, N
    Reino, A
    Lawson, W
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1998, 124 (01) : 56 - 59
  • [27] Endoscopically assisted repair of orbital floor fractures
    Chen, CT
    Chen, YR
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2001, 108 (07) : 2011 - 2018
  • [28] MR IMAGING OF ORBITAL BLOW-OUT FRACTURES
    MCARDLE, CB
    AMPARO, EG
    MIRFAKHRAEE, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (01) : 116 - 119
  • [29] ASSESSMENT OF THE DAMAGES BY ORBITAL BLOW-OUT FRACTURES
    MOMMAERTS, MY
    CASSELMAN, JW
    ACTA CHIRURGICA BELGICA, 1993, (05) : 201 - 206
  • [30] Resorbable polylactic acid polymer plates in repair of blow-out orbital floor fractures
    Esmail, Mohamed Esmail Khalil
    Ibrahiem, Mohamed Farag Khalil
    Abdallah, Raafat Mohyeldeen Abdelrahman
    Elshafei, Ahmed Mohamed Kamal
    Gawdat, Tamer Ismail
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (03) : 1384 - 1390