Task-driven image acquisition and reconstruction in cone-beam CT

被引:25
|
作者
Gang, Grace J. [1 ]
Stayman, J. Webster [1 ]
Ehtiati, Tina [2 ]
Siewerdsen, Jeffrey H. [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Siemens Healthcare AX Div, Forcheim, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 08期
关键词
task-driven imaging; detectability index; cone-beam CT; tube current modulation; reconstruction kernel; orbital tilt; image quality; HUMAN-OBSERVER PERFORMANCE; CASCADED SYSTEMS-ANALYSIS; COMPUTED-TOMOGRAPHY; NOISE POWER; OPTIMIZATION; SIGNAL; ARM; DETECTABILITY; QUALITY; MODEL;
D O I
10.1088/0031-9155/60/8/3129
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work introduces a task-driven imaging framework that incorporates a mathematical definition of the imaging task, a model of the imaging system, and a patient-specific anatomical model to prospectively design image acquisition and reconstruction techniques to optimize task performance. The framework is applied to joint optimization of tube current modulation, view-dependent reconstruction kernel, and orbital tilt in cone-beam CT. The system model considers a cone-beam CT system incorporating a flat-panel detector and 3D filtered backprojection and accurately describes the spatially varying noise and resolution over a wide range of imaging parameters in the presence of a realistic anatomical model. Task-based detectability index (d') is incorporated as the objective function in a task-driven optimization of image acquisition and reconstruction techniques. The orbital tilt was optimized through an exhaustive search across tilt angles ranging +/- 30 degrees. For each tilt angle, the view-dependent tube current and reconstruction kernel (i.e. the modulation profiles) that maximized detectability were identified via an alternating optimization. The task-driven approach was compared with conventional unmodulated and automatic exposure control (AEC) strategies for a variety of imaging tasks and anthropomorphic phantoms. The task-driven strategy outperformed the unmodulated and AEC cases for all tasks. For example, d' for a sphere detection task in a head phantom was improved by 30% compared to the unmodulated case by using smoother kernels for noisy views and distributing mAs across less noisy views (at fixed total mAs) in a manner that was beneficial to task performance. Similarly for detection of a line-pair pattern, the task-driven approach increased d' by 80% compared to no modulation by means of view-dependent mA and kernel selection that yields modulation transfer function and noise-power spectrum optimal to the task. Optimization of orbital tilt identified the tilt angle that reduced quantum noise in the region of the stimulus by avoiding highly attenuating anatomical structures. The task-driven imaging framework offers a potentially valuable paradigm for prospective definition of acquisition and reconstruction protocols that improve task performance without increase in dose.
引用
收藏
页码:3129 / 3150
页数:22
相关论文
共 50 条
  • [1] Task-Driven Imaging in Cone-Beam Computed Tomography
    Gang, G. J.
    Stayman, J. W.
    Ouadah, S.
    Ehtiati, T.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [2] Task-Driven Orbit Design and Implementation on a Robotic C-Arm System for Cone-Beam CT
    Ouadah, S.
    Jacobson, M.
    Stayman, J. W.
    Ehtiati, T.
    Weiss, C.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [3] FEATURED PRESENTATION and BEST IN PHYSICS (IMAGING): Task-Driven Imaging for Cone-Beam CT in Interventional Guidance
    Gang, G.
    Stayman, J.
    Ouadah, S.
    Ehtiati, T.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3680 - 3681
  • [4] Cone-Beam CT Reconstruction with Deformed Prior Image
    Zhang, H.
    Ouyang, L.
    Huang, J.
    Ma, J.
    Chen, W.
    Wang, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 527 - 527
  • [5] Cone-Beam CT Image Reconstruction with Spherical Harmonics
    Shimomura, T.
    Haga, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E391 - E392
  • [6] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [7] Task-based statistical image reconstruction for high-quality cone-beam CT
    Dang, Hao
    Stayman, J. Webster
    Xu, Jennifer
    Zbijewski, Wojciech
    Sisniega, Alejandro
    Mow, Michael
    Wang, Xiaohui
    Foos, David H.
    Aygun, Nafi
    Koliatsos, Vassilis E.
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (22): : 8693 - 8719
  • [8] OR-EM Method for Image Reconstruction in Cone-beam CT
    Dong, Baoyu
    PROCEEDINGS OF THE FIRST INTERNATIONAL WORKSHOP ON EDUCATION TECHNOLOGY AND COMPUTER SCIENCE, VOL I, 2009, : 635 - 639
  • [9] Image reconstruction in reduced circular sinusoidal cone-beam CT
    Xia, Dan
    Cho, Seungryong
    Pan, Xiaochuan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2009, 17 (03) : 189 - 205
  • [10] Cone-beam CT image reconstruction with extended z range
    Grimmer, Rainer
    Oelhafen, Markus
    Elstrom, Ulrik
    Kachelriess, Marc
    MEDICAL PHYSICS, 2009, 36 (07) : 3363 - 3370