A Simple Perceptive Diphenyl-Imidazole-Based Dipodal Schiff-Base Chemosensor for Zn2+ and PPi ions and Its Live-Cell Imaging Applications

被引:15
|
作者
Gomathi, Asaithambi [1 ]
Vasanthi, Mani [1 ]
Viswanthamurthi, Periasamy [1 ]
Suresh, Shanmugan [2 ]
Nandhakumar, Raju [2 ]
机构
[1] Periyar Univ, Dept Chem, Salem 636011, India
[2] Karunya Univ, Dept Chem, Coimbatore 641114, Tamil Nadu, India
来源
CHEMISTRYSELECT | 2018年 / 3卷 / 42期
关键词
Detection Limit; Fluorescent Probe; Live Cell Imaging; Pyrophosphate Ion Detection; Zinc Ion Detection; SEQUENTIAL DETECTION; FLUORESCENT SENSOR; HYDROGEN-SULFIDE; ZINC; PYROPHOSPHATE; RECOGNITION; PROBE; RESPONSES; PICOMOLAR; AFFINITY;
D O I
10.1002/slct.201802233
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
2,6-bis((E)-(2-(benzo[d]thiazol-2-yl)hydrazono)methyl)-4-(4,5-diphenyl-1H-imidazol-2-yl)phenol (PIS) conjugate has been designed as a selective fluorescent probe for zinc ion. The PIS exhibits selectivity towards Zn2+ among various ions in DMSO-H2O (1:9) v/v 50 mM HEPES (4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid) at pH=7.4. Moreover, the detection of PIS towards Zn2+ ion could be realized in (")naked eye" with a color conversion from yellow to greenish yellow. The linear relationship between fluorescence intensity and Zn2+ ion concentration indicates that PIS can be used for quantification of Zn2+ ion. The PIS probe can be used in broad pH ranging from 4 to 9. The limit of detection (LOD) was found to be 0.52 nM for Zn2+ ion. The binding ratio and binding constant of PIS-Zn2+ complex were determined and calculated as 1:1 and 2.36x10(6) M-1 according to Job ' s plot and Benesi-Hildebrand equation, respectively. Furthermore, the PIS-Zn2+ complex subsequently acted as a secondary fluorescent turn-off probe for pyrophosphate (PPi) ion recognition among the other anions. To assess the real-world efficacy of the PIS and PIS-Zn2+ complex, they were evaluated by test paper strips. Likewise, the probe PIS and PIS-Zn2+ complex were used as in vitro cell imaging probe, and successfully demonstrated as feasible bio-marker as well.
引用
收藏
页码:11809 / 11815
页数:7
相关论文
共 50 条
  • [31] A highly selective coumarin-based chemosensor for dual sensing of Cu2+ and Zn2+ ions with logic gate integration and live cell imaging
    Singh, Avanish Kumar
    Singh, Amit Kumar
    Sharma, Shashi Kant
    Sonkar, Vijay Kumar
    Singh, Vinod P.
    ANALYTICAL METHODS, 2024, 16 (27) : 4551 - 4560
  • [32] New pyridoxal based chemosensor for selective detection of Zn2+: Application in live cell imaging and phosphatase activity response
    Mandal, Senjuti
    Sikdar, Yeasin
    Malti, Dilip K.
    Sanyal, Ria
    Das, Debasis
    Mukherjee, Abhishek
    Mandal, Sushil Kumar
    Biswas, Jayanta Kumar
    Bauza, Antonio
    Frontera, Antonio
    Goswami, Sanchita
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2017, 334 : 86 - 100
  • [33] A Novel Thiophene-Based Fluorescent Chemosensor for the Detection of Zn2+ and CN- : Imaging Applications in Live Cells and Zebrafish
    Kim, Min Seon
    Yun, Dongju
    Chae, Ju Byeong
    So, Haeri
    Lee, Hyojin
    Kim, Ki-Tae
    Kim, Mingeun
    Lim, Mi Hee
    Kim, Cheal
    SENSORS, 2019, 19 (24)
  • [34] Differentially Selective Chemosensor with Fluorescence Off-On Responses on Cu2+ and Zn2+ Ions in Aqueous Media and Applications in Pyrophosphate Sensing, Live Cell Imaging, and Cytotoxicity
    Anbu, Sellamuthu
    Ravishankaran, Rajendran
    Guedes da Silva, M. Fatima C.
    Karande, Anjali A.
    Pombeiro, Armando J. L.
    INORGANIC CHEMISTRY, 2014, 53 (13) : 6655 - 6664
  • [35] Deciphering the CHEF-PET-ESIPT liaison mechanism in a Zn2+ chemosensor and its applications in cell imaging study
    Jana, Atanu
    Das, Bhriguram
    Mandal, Sushil K.
    Mabhai, Subhabrata
    Khuda-Bukhsh, Anisur R.
    Dey, Satyajit
    NEW JOURNAL OF CHEMISTRY, 2016, 40 (07) : 5976 - 5984
  • [36] RETRACTED: A new quinoline-based chemosensor for Zn2+ ions and their application in living cell imaging (Retracted Article)
    Ponnuvel, Kandasamy
    Kumar, Madasamy
    Padmini, Vediappen
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 227 : 242 - 247
  • [37] Fluorogenic recognition of Zn2+, Cd2+ by a new Pyrazoline-based Multi-Analyte chemosensor and its application in live cell imaging
    Zhang, Ying-Peng
    Niu, Wei -Ya
    Ma, Chun-Mei
    Yang, Yun-Shang
    Guo, Hui-Chen
    Xue, Ji -Jun
    INORGANIC CHEMISTRY COMMUNICATIONS, 2021, 130
  • [38] a Versatile Schiff Base Chemosensor for the Determination of Trace Co2+, Ni2+, Cu2+, and Zn2+ in the Water and Its Bioimaging Applications
    Liu, Hongmei
    Ding, Shangli
    Lu, Quan
    Jian, Yue
    Wei, Gang
    Yuan, Zeli
    ACS OMEGA, 2022, 7 (09): : 7585 - 7594
  • [39] Methionine-derived Schiff base as selective fluorescent "turn-on" chemosensor for Zn2+ in aqueous medium and its application in living cells imaging
    Faiz-Ur-Rahman
    Ali, Amjad
    Guo, Rong
    Tian, Jia
    Wang, Hui
    Li, Zhan-Ting
    Zhang, Dan-Wei
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 211 : 544 - 550
  • [40] Synthesis and photophysical investigation of (BTHN) Schiff base as off-on Cd2+ fluorescent chemosensor and its live cell imaging
    Khan, Salman A.
    Ullah, Qasim
    Almalki, Abdulraheem S. A.
    Kumar, Sanjay
    Obaid, Rami J.
    Alsharif, Meshari A.
    Alfaifi, S. Y.
    Hashmi, Authar Adil
    JOURNAL OF MOLECULAR LIQUIDS, 2021, 328