Dose response of the individual peak for LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (GR-200A) TL materials at the photon energies of 30, 104, 1250 keV

被引:11
|
作者
Cai, GG
Bestion, N
Wang, SS
Shen, WX
Delard, R
Volpiliere, J
Fesquet, J
Gasiot, J
机构
关键词
D O I
10.1093/oxfordjournals.rpd.a031625
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The dose responses for LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (GR-200A) have been examined at the photon energies of 30, 104 and 1250 keV. A GCA program has been used for the deconvolution of the glow peaks and the behaviours of the individual peaks have been analysed. For TLD-100, an increasing supralinearity was observed for the higher temperature peaks, and the supralinearity at 30 keV was lower than that at 1250 keV. For GR-200A, peak 4 showed supralinearity around 10 Gy. A possible correlation seems to exist between the energy response and dose response. A brief discussion and explanation are provided.
引用
收藏
页码:213 / 215
页数:3
相关论文
共 39 条
  • [1] FIELD APPLICATION OF LIF-MG,CU,P (GR200A) AND LIF-MG,TI (TLD-100) THERMOLUMINESCENT MATERIALS IN ENVIRONMENTAL DOSIMETRY
    BRAI, M
    PUCCIO, P
    BARTOLOTTA, A
    FERRARA, G
    HAUSER, S
    RIZZO, S
    RADIATION PROTECTION DOSIMETRY, 1994, 55 (02) : 107 - 111
  • [2] A comparative analysis of three thermoluminescent phosphors LiF:Mg,Ti (TLD-100), LiF:Mg,Cu and LiF:Mg,Cu,P
    Srivastava, JK
    Bhatt, BC
    Yoshimura, EM
    Okuno, E
    Sunta, CM
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 191 - 194
  • [4] The thermoluminescence (TL) dose response of composite peak 5 in LiF:Mg,Ti (TLD-100): dependence on the order of kinetics
    Nemirovsky, Dimitry
    Oster, Leonid
    Reshes, Galina
    Biderman, Shlomo
    Bokobza, Yogev
    Sterenberg, Matan
    Eliyahu, Ilan
    Shapiro, Alexander
    Herman, Benny
    Horowitz, Yigal
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (06) : 498 - 508
  • [5] A PRECISE INVESTIGATION ON THE TL BEHAVIOR OF LIF-MG, CU, P (GR-200A)
    FURETTA, C
    LEROY, C
    LAMARCHE, F
    MEDICAL PHYSICS, 1994, 21 (10) : 1605 - 1609
  • [6] AN IMPROVED METHOD FOR THE COMPUTERISED ANALYSIS OF GR-200A LiF:Mg, Cu,P TL SIGNALS
    Cui, H.
    Tang, K.
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (02) : 184 - 189
  • [7] Dose response of F center optical absorption in LiF:Mg,Ti (TLD-100)
    Biderman, S.
    Eliyahu, I.
    Horowitz, Y. S.
    Oster, L.
    RADIATION MEASUREMENTS, 2014, 71 : 237 - 241
  • [8] A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry
    Al-Haj, Abdalla
    Lagarde, Charlie
    Mahyoub, Fareed
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 399 - 402
  • [9] Thermoluminescence of LiF:Mg,Cu,P (GR-200A) TLD after annealing between 200 and 400 degrees C
    Cai, GG
    Fesquet, J
    Dusseau, L
    Martini, M
    Meinardi, F
    Huang, BL
    Tang, KY
    Beteille, D
    Gasiot, J
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 163 - 166
  • [10] The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF:Mg,Ti (TLD-100)
    Horowitz, Y. S.
    Oster, L.
    Datz, H.
    RADIATION PROTECTION DOSIMETRY, 2007, 124 (02) : 191 - 205