Temperature hysteresis in a GM-Type orifice pulse tube refrigerator

被引:0
|
作者
Gan, Z. H. [1 ]
Thummes, G. [1 ]
机构
[1] Zhejiang Univ, Cryogen Lab, Hangzhou 310027, Peoples R China
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Compared to the instability in some double-inlet pulse tube refrigerators due to the DC-flow in the cooling system, the single orifice pulse tube refrigerator (OPTR) is usually considered to operate stably. However, in recent experiments we found a new phenomenon in form of a temperature hysteresis in a single stage GM-type OPTR that depends on the heat load and on the adjustment of the needle valve connecting the pulse tube warm end with the buffer volume. The lowest temperature of this cooler, when operated on a 6 kW compressor, was 18.8 K with double inlet and 30.4 K with single orifice.
引用
收藏
页码:297 / 300
页数:4
相关论文
共 50 条
  • [31] Analysis of an orifice pulse tube refrigerator using the method of characteristics
    Xu, MY
    He, YL
    Chen, ZQ
    CRYOGENICS, 1999, 39 (09) : 751 - 757
  • [32] Optimal design of thermal performance of an orifice pulse tube refrigerator
    Debashis Panda
    Manoj Kumar
    Ashok K. Satapathy
    Sunil K. Sarangi
    Journal of Thermal Analysis and Calorimetry, 2021, 143 : 3589 - 3609
  • [33] Thermodynamic comparison between the orifice pulse tube and the stirling refrigerator
    deBoer, PCT
    CRYOCOOLERS 9, 1997, : 431 - 440
  • [34] Optimal design of thermal performance of an orifice pulse tube refrigerator
    Panda, Debashis
    Kumar, Manoj
    Satapathy, Ashok K.
    Sarangi, Sunil K.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 143 (05) : 3589 - 3609
  • [35] CFD simulation and experimental validation of a GM type double inlet pulse tube refrigerator
    Banjare, Y. P.
    Sahoo, R. K.
    Sarangi, S. K.
    CRYOGENICS, 2010, 50 (04) : 271 - 280
  • [36] Computational fluid dynamics simulations of an orifice type pulse tube refrigerator: Effects of operating frequency
    Antao, Dion Savio
    Farouk, Bakhtier
    CRYOGENICS, 2011, 51 (04) : 192 - 201
  • [37] Experimental results of a single stage linear orifice pulse tube refrigerator
    Ishimura, M
    Bodegom, E
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 1965 - 1972
  • [38] DC flow analysis and second orifice version pulse tube refrigerator
    Yang, LW
    Zhou, Y
    Liang, JT
    CRYOGENICS, 1999, 39 (03) : 187 - 192
  • [39] Two-dimensional numerical simulation of orifice pulse tube refrigerator
    Zhao, Chun-Feng
    He, Ya-Ling
    Huang, Jing
    Liu, Ying-Wen
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2007, 28 (SUPPL. 1): : 45 - 48
  • [40] DC flow analysis and second orifice version pulse tube refrigerator
    Cryogenic Laboratory, Chinese Acad. Sci., Post B., Beijing, China
    Cryogenics, 3 (187-192):