Temperature hysteresis in a GM-Type orifice pulse tube refrigerator

被引:0
|
作者
Gan, Z. H. [1 ]
Thummes, G. [1 ]
机构
[1] Zhejiang Univ, Cryogen Lab, Hangzhou 310027, Peoples R China
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Compared to the instability in some double-inlet pulse tube refrigerators due to the DC-flow in the cooling system, the single orifice pulse tube refrigerator (OPTR) is usually considered to operate stably. However, in recent experiments we found a new phenomenon in form of a temperature hysteresis in a single stage GM-type OPTR that depends on the heat load and on the adjustment of the needle valve connecting the pulse tube warm end with the buffer volume. The lowest temperature of this cooler, when operated on a 6 kW compressor, was 18.8 K with double inlet and 30.4 K with single orifice.
引用
收藏
页码:297 / 300
页数:4
相关论文
共 50 条
  • [1] Temperature loop, a new phenomenon in a GM-type orifice pulse tube refrigerator
    Gan, Zhi-Hua
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2005, 26 (03): : 388 - 390
  • [2] Optimal pulse tube volume design in GM-type pulse tube refrigerator
    Jung, Jeheon
    Jeong, Sangkwon
    CRYOGENICS, 2007, 47 (9-10) : 510 - 516
  • [3] Buffered rotary valve system of GM-type pulse tube refrigerator
    Hwang, G.
    Jung, J.
    Jeong, S.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 93 - +
  • [4] Waiting time effect of a GM type orifice pulse tube refrigerator
    Zhu, SW
    Kakimi, Y
    Matsubara, Y
    CRYOGENICS, 1998, 38 (06) : 619 - 624
  • [5] Development of a GM-type pulse tube refrigerator cooling system for superconducting Maglev vehicles
    Kondo, Y
    Terai, M
    Nishikawa, Y
    Sugiyama, O
    Inoue, T
    Hirano, A
    Goto, T
    Fujii, S
    Jizo, Y
    Amano, T
    Cryocoolers 13, 2005, : 681 - 687
  • [6] Numerical Study of Single Stage GM-Type Pulse Tube Refrigerator for HTc-Superconductors
    Raju
    Ghosh, Suman
    PROCEEDINGS OF THE 25TH NATIONAL AND 3RD INTERNATIONAL ISHMT-ASTFE HEAT AND MASS TRANSFER CONFERENCE, IHMTC 2019, 2019,
  • [7] Thermodynamic analysis of GM-type pulse tube coolers
    Ju, YL
    CRYOGENICS, 2001, 41 (07) : 513 - 520
  • [8] Numerical and experimental investigations on a single stage GM-type double inlet pulse tube refrigerator for nitrogen liquefaction
    Panda, Debashis
    Kumar, Manoj
    Satapathy, Ashok K.
    Sarangi, Sunil K.
    Sahoo, Ranjit K.
    PROCEEDINGS OF THE 25TH NATIONAL AND 3RD INTERNATIONAL ISHMT-ASTFE HEAT AND MASS TRANSFER CONFERENCE, IHMTC 2019, 2019,
  • [9] Performance Evaluation of a GM-Type Double Inlet Pulse Tube Refrigerator Using Artificial Intelligence Approach with Experimental Validation
    Panda, Debashis
    Kumar, Manoj
    Satapathy, A. K.
    Sarangi, S. K.
    Sahoo, R. K.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (11) : 9579 - 9597
  • [10] Performance Evaluation of a GM-Type Double Inlet Pulse Tube Refrigerator Using Artificial Intelligence Approach with Experimental Validation
    Debashis Panda
    Manoj Kumar
    A. K. Satapathy
    S. K. Sarangi
    R. K. Sahoo
    Arabian Journal for Science and Engineering, 2020, 45 : 9579 - 9597