Monte Carlo simulation of the CENBG microbeam and nanobeam lines with the Geant4 toolkit

被引:32
|
作者
Incerti, S.
Zhang, Q.
Andersson, F.
Moretto, Ph.
Grime, G. W.
Merchant, M. J.
Nguyen, D. T.
Habchi, C.
Pouthier, T.
Seznec, H.
机构
[1] Univ Bordeaux 1, Ctr Etud Nucl Bordeaux Grodignan, CNRS IN2P3, UMR 5797, F-33175 Gradignan, France
[2] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
基金
英国工程与自然科学研究理事会;
关键词
Monte Carlo; Geant4; ray tracings; quadrupoles;
D O I
10.1016/j.nimb.2007.01.274
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A single-ended HVEE (R) 3.5 MV Singletron electrostatic accelerator has been installed since October 2005 at the Centre d'Etudes Nucleaires de Bordeaux-Gradignan (CENBG) in France. This facility is equipped with a microbeam line dedicated to ion beam analysis (scanning transmission ion microscopy - STIM, particle induced X-ray emission - PIXE, Rutherford back scattering) and cellular irradiation in single event mode. A high demagnification nanobeam line will be installed on the same facility in the near future. This paper focuses on the simulation of the microbeam and nanobeam lines performances using the Geant4 Monte Carlo simulation toolkit. Comparisons with experimental data collected on the microbeam line are presented. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 50 条
  • [41] The Effect of Beam Polarization in Microbeam Radiation Therapy (MRT): Monte Carlo Simulations Using Geant4
    Spiga, J.
    Prezado, Y.
    Braeuer-Krisch, E.
    Fanti, V.
    Randaccio, P.
    Bravin, A.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2170 - +
  • [42] The Geant4 Toolkit: simulation capabilities and application results
    Pia, MG
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 125 : 60 - 68
  • [43] Geant4 Monte Carlo simulations for the LPCTrap setup
    Rodriguez, D.
    Ban, G.
    Durand, D.
    Duval, F.
    Flechard, X.
    Lienard, E.
    Mauger, F.
    Mery, A.
    Naviliat-Cuncic, O.
    Thomas, J. -C.
    Velten, Ph.
    EUROPEAN PHYSICAL JOURNAL A, 2009, 42 (03): : 397 - 400
  • [44] Geant4 Monte Carlo simulations for the LPCTrap setup
    D. Rodríguez
    G. Ban
    D. Durand
    F. Duval
    X. Fléchard
    E. Liénard
    F. Mauger
    A. Méry
    O. Naviliat-Cuncic
    J. -C. Thomas
    Ph. Velten
    The European Physical Journal A, 2009, 42 : 397 - 400
  • [45] The GEANT4 toolkit for microdosimetry calculations:: Application to microbeam radiation therapy (MRT)
    Spiga, J.
    Siegbahn, E. A.
    Braeuer-Krisch, E.
    Randaccio, P.
    Bravin, A.
    MEDICAL PHYSICS, 2007, 34 (11) : 4322 - 4330
  • [46] Monte Carlo simulations in proton dosimetry with Geant4
    Moravek, Z
    Bogner, L
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [47] Dosimetric evaluation of nuclear interaction models in the Geant4 Monte Carlo simulation toolkit for carbon-ion radiotherapy.
    Kameoka S.
    Amako K.
    Iwai G.
    Murakami K.
    Sasaki T.
    Toshito T.
    Yamashita T.
    Aso T.
    Kimura A.
    Kanai T.
    Kanematsu N.
    Komori M.
    Takei Y.
    Yonai S.
    Tashiro M.
    Koikegami H.
    Tomita H.
    Koi T.
    Radiological Physics and Technology, 2008, 1 (2) : 183 - 187
  • [48] Emission of Secondary Particles From a PMMA Phantom During Proton Irradiation: A Simulation Study with the Geant4 Monte Carlo Toolkit
    Lau, A.
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 346 - 346
  • [49] An overview of the Geant4 toolkit
    Apostolakis, John
    Wright, Dennis H.
    HADRONIC SHOWER SIMULATION WORKSHOP, 2007, 896 : 1 - +
  • [50] Development of a complete simulation package for Self-Powered Neutron Detectors using the Monte Carlo Method and Geant4 toolkit
    Li, Kun
    Li, Gang
    Wan, Bo
    Yang, Daibo
    Li, Dan
    Weng, Xiaohui
    Li, Ang
    Yin, Qiusheng
    Wang, Haibo
    JOURNAL OF INSTRUMENTATION, 2023, 18 (08)