Significance of angiographic coronary dissection after cutting balloon angioplasty

被引:10
|
作者
Martí, V [1 ]
Martín, V [1 ]
García, J [1 ]
Guiteras, P [1 ]
Augé, JM [1 ]
机构
[1] Hosp Santa Cruz & San Pablo, Dept Cardiol & Cardiac Surg, Intervent Cardiol Unit, E-08025 Barcelona, Spain
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1998年 / 81卷 / 11期
关键词
D O I
10.1016/S0002-9149(98)00165-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We studied 2 groups of patients with (n = 14) and without (n = 42) minor coronary dissections following cutting balloon angioplasty. Patients with a minor dis section had a longer length of lesion, higher percentage of stenosis, and greater acute gain after angioplasty; at 6-month follow-up both groups had a similar net gain and restenosis rate, suggesting that minor dissection after cutting balloon angioplasty has no influence on restenosis.
引用
收藏
页码:1349 / +
页数:5
相关论文
共 50 条
  • [31] Six-month angiographic and clinical outcomes after successful eccentric excimer laser coronary angioplasty with adjunctive cutting balloon angioplasty for recurrent in-stent restenosis
    Chen, Ching-Pei
    Huang, Chung-Li
    Fong, Chih-Chung
    Wu, Xian-Nin
    Pai, Chi-Hsien
    Chang, Yung-Ming
    ACTA CARDIOLOGICA SINICA, 2008, 24 (01) : 15 - 20
  • [32] COMPARATIVE QUANTITATIVE ANGIOGRAPHIC ANALYSIS OF DIRECTIONAL CORONARY ATHERECTOMY AND BALLOON CORONARY ANGIOPLASTY
    UMANS, VAWM
    BEATT, KJ
    RENSING, BJWM
    HERMANS, WRM
    DEFEYTER, PJ
    SERRUYS, PW
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (17): : 1556 - 1563
  • [33] EFFECT OF ANGIOGRAPHIC AND HEMODYNAMIC-RESULTS OF CORONARY BALLOON ANGIOPLASTY ON LATE ANGIOGRAPHIC OUTCOME
    LIU, MW
    ROUBIN, GS
    KING, SB
    AMERICAN HEART JOURNAL, 1994, 128 (06) : 1077 - 1083
  • [34] OUTCOME AFTER MAJOR DISSECTION DURING CORONARY ANGIOPLASTY USING THE PERFUSION BALLOON CATHETER
    LEITSCHUH, ML
    MILLS, RM
    JACOBS, AK
    RUOCCO, NA
    LAROSA, D
    FAXON, DP
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (13): : 1056 - 1060
  • [35] ARE CLINICAL, ANGIOGRAPHIC OR PROCEDURAL VARIABLES PREDICTIVE OF LUMINAL RENARROWING AFTER SUCCESSFUL CORONARY BALLOON ANGIOPLASTY
    SERRUYS, PW
    HERMANS, WR
    RENSING, BJ
    TIJSSEN, J
    RUTSCH, W
    EMANUELSSON, H
    DANCHIN, N
    WIJNS, W
    CIRCULATION, 1992, 86 (04) : 849 - 849
  • [36] PREDICTORS OF CORONARY DISSECTION FOLLOWING PERCUTANEOUS TRANSLUMINAL CORONARY BALLOON ANGIOPLASTY
    ILIA, R
    BIGHAM, H
    BRENNAN, J
    CABIN, H
    CLEMAN, M
    REMETZ, M
    CARDIOLOGY, 1994, 85 (3-4) : 229 - 234
  • [37] Early results with infrainguinal cutting balloon angioplasty limits distal dissection
    Rabbi, JF
    Kiran, RP
    Gersten, G
    Dudrick, SJ
    Dardik, A
    ANNALS OF VASCULAR SURGERY, 2004, 18 (06) : 640 - 643
  • [38] Cutting Balloon Versus Conventional Balloon Angioplasty for the Treatment of Coronary Artery Disease
    Albiero, Remo
    EUROPEAN CARDIOLOGY REVIEW, 2005, : 48 - 52
  • [39] CORONARY-ARTERY DISSECTION CAUSED BY ANGIOPLASTY BALLOON RUPTURE
    ROTHSCHILD, R
    VODA, J
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 19 (01): : 26 - 29
  • [40] Cutting balloon angioplasty versus stenting in small coronary vessels: Acute and long-term angiographic results.
    Kawaguchi, K
    Kondo, T
    Murakami, H
    Miura, M
    Kakegawa, Y
    Awaji, Y
    Mochizuki, M
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (8A): : 62I - 62I