Underground metro stations; Indoor air quality; Exposure limit; Particulate matter; Volatile organic compounds; Bio-aerosols; VOLATILE ORGANIC-COMPOUNDS; PARTICULATE MATTER CONCENTRATIONS; PUBLIC TRANSPORTATION MODES; SEOUL METROPOLITAN SUBWAY; CONDITIONED OFFICE BUILDINGS; RAILWAY TRANSIT SYSTEM; CARBONYL-COMPOUNDS; PERSONAL EXPOSURE; AIRBORNE FUNGI; MEXICO-CITY;
D O I
10.1016/j.buildenv.2021.107907
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research paper presents a comprehensive review of different types of air pollutants, their concentration levels, sources contributing to air pollution, health impacts of pollutants, characteristics of air pollutants, influencing factors such as thermal characteristics and subway geometry, and Indoor Air Quality (IAQ) management in underground (UG) Metro stations. In the current study, actual levels of air pollutants were compared with guidelines specified by regulatory agencies to assess the risk of high exposure to toxic levels of air pollutants. It was found that exposure to particulate matter (PM), volatile organic compounds (VOCs), and bacteria were critical as levels were 2-10 times higher in UG metro stations than the permissible exposure limits specified by WHO, EPA, and ACGIH. Concentrations of aromatic VOCs were noted to be high in urban areas while concentrations of carbonyl VOCs were high in suburban areas. High bacterial concentrations were attributed to increased passenger traffic and saturation of air cleaning filters in HVAC systems. Several factors such as station design, depth of the tunnel, indoor thermal conditions, density of passengers, frequency of trains, station locality, and outdoor environmental conditions were found to significantly affect the IAQ of subway metro stations. On the basis of existing studies as well as the current review study, it is recommended that future research work could focus on the characterization of different gaseous and biological air pollutants, health risk assessment of exposure to various air pollutants, and field studies on the influence of thermal parameters on IAQ perception in UG metro stations.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Investigation of radon concentrations of underground metro and Marmaray stations in Istanbul
    Alan, H. Yilmaz
    Akkus, B.
    Susam, L. Amon
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2019, 322 (02) : 291 - 304
  • [42] The use of models in the design of deep underground metro stations in Amsterdam
    Herbschleb, J
    de Wit, JCWM
    (RE)CLAIMING THE UNDERGROUND SPACE, VOLS 1 AND 2, PROCEEDINGS, 2003, : 1113 - 1117
  • [43] Seismic design of shallow immersed tunnels and underground metro stations
    Pitilakis, K.
    PERFORMANCE-BASED DESIGN IN EARTHQUAKE GEOTECHNICAL ENGINEERING - FROM CASE HISTORY TO PRACTICE, 2009, : 239 - 240
  • [44] Evaluation of comfort perception of passengers in urban underground metro stations
    Passi, Amit
    Nagendra, S. M. Shiva
    Maiya, M. P.
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2022, 68 : 273 - 288
  • [45] Anti-inundation measures for underground stations of Tokyo Metro
    Aoki, Yoji
    Yoshizawa, Atsushi
    Taminato, Tomoya
    15TH INTERNATIONAL SCIENTIFIC CONFERENCE UNDERGROUND URBANISATION AS A PREREQUISITE FOR SUSTAINABLE DEVELOPMENT, 2016, 165 : 2 - 10
  • [46] Research Strategies on New Prefabricated Technology for Underground Metro Stations
    Yang, Xiuren
    Huang, Meiqun
    Lin, Fang
    URBAN RAIL TRANSIT, 2019, 5 (03) : 145 - 154
  • [47] Investigation of radon concentrations of underground metro and Marmaray stations in Istanbul
    H. Yilmaz Alan
    B. Akkus
    L. Amon Susam
    Journal of Radioanalytical and Nuclear Chemistry, 2019, 322 : 291 - 304
  • [48] Fire and Life Safety Systems at Delhi Metro Underground Stations
    Gupta, Anoop Kumar
    Singh, Abdhesh Kumar
    Jain, Rajesh Kumar
    2017 ASHRAE ANNUAL CONFERENCE PAPERS, 2017,
  • [49] Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground
    Kim, Won Taek
    Kwon, Byung Hyun
    Shin, Yong Chul
    Kang, Dong Mug
    Ki, Yong Kan
    Kim, Dong Won
    RADIATION ONCOLOGY JOURNAL, 2005, 23 (04): : 242 - 252
  • [50] Indoor air quality and its determinants in underground shopping malls in Korea
    Kim, Jeonghoon
    Shim, In-Keun
    Won, Soo Ran
    Hwang, Eun Seol
    Lee, Yumi
    Park, Sujung
    Ryu, Jungmin
    Lee, Jongchun
    ENVIRONMENT INTERNATIONAL, 2024, 183