Characteristics of indoor air quality in underground metro stations: A critical review

被引:58
|
作者
Passi, Amit [1 ]
Nagendra, S. M. Shiva [1 ]
Maiya, M. P. [2 ]
机构
[1] Indian Inst Technol Madras, Dept Civil Engn, Chennai 600036, Tamil Nadu, India
[2] Indian Inst Technol Madras, Dept Mech Engn, Chennai 600036, Tamil Nadu, India
关键词
Underground metro stations; Indoor air quality; Exposure limit; Particulate matter; Volatile organic compounds; Bio-aerosols; VOLATILE ORGANIC-COMPOUNDS; PARTICULATE MATTER CONCENTRATIONS; PUBLIC TRANSPORTATION MODES; SEOUL METROPOLITAN SUBWAY; CONDITIONED OFFICE BUILDINGS; RAILWAY TRANSIT SYSTEM; CARBONYL-COMPOUNDS; PERSONAL EXPOSURE; AIRBORNE FUNGI; MEXICO-CITY;
D O I
10.1016/j.buildenv.2021.107907
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research paper presents a comprehensive review of different types of air pollutants, their concentration levels, sources contributing to air pollution, health impacts of pollutants, characteristics of air pollutants, influencing factors such as thermal characteristics and subway geometry, and Indoor Air Quality (IAQ) management in underground (UG) Metro stations. In the current study, actual levels of air pollutants were compared with guidelines specified by regulatory agencies to assess the risk of high exposure to toxic levels of air pollutants. It was found that exposure to particulate matter (PM), volatile organic compounds (VOCs), and bacteria were critical as levels were 2-10 times higher in UG metro stations than the permissible exposure limits specified by WHO, EPA, and ACGIH. Concentrations of aromatic VOCs were noted to be high in urban areas while concentrations of carbonyl VOCs were high in suburban areas. High bacterial concentrations were attributed to increased passenger traffic and saturation of air cleaning filters in HVAC systems. Several factors such as station design, depth of the tunnel, indoor thermal conditions, density of passengers, frequency of trains, station locality, and outdoor environmental conditions were found to significantly affect the IAQ of subway metro stations. On the basis of existing studies as well as the current review study, it is recommended that future research work could focus on the characterization of different gaseous and biological air pollutants, health risk assessment of exposure to various air pollutants, and field studies on the influence of thermal parameters on IAQ perception in UG metro stations.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A review on characteristics and mitigation strategies of indoor air quality in underground subway stations
    Yang, Junbin
    Fan, Xianwang
    Zhang, Huan
    Zheng, Wandong
    Ye, Tianzhen
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 869
  • [2] Occupational exposure and personal exposure to hazardous air pollutants in underground metro stations and factors causing poor indoor air quality
    Amit Passi
    S. M. Shiva Nagendra
    M. P. Maiya
    Air Quality, Atmosphere & Health, 2023, 16 : 1851 - 1870
  • [3] Occupational exposure and personal exposure to hazardous air pollutants in underground metro stations and factors causing poor indoor air quality
    Passi, Amit
    Nagendra, S. M. Shiva
    Maiya, M. P.
    AIR QUALITY ATMOSPHERE AND HEALTH, 2023, 16 (09): : 1851 - 1870
  • [4] Characteristics of the thermal environment, air quality, and passenger comfort in the underground transfer space of metro stations in Beijing
    Lin, Chunxiang
    Wu, Liming
    Xia, Haishan
    Zhen, Meng
    Shen, Chen
    Zhu, Jinjin
    Li, Xinyi
    JOURNAL OF BUILDING ENGINEERING, 2022, 59
  • [5] Indoor air quality and passenger thermal comfort in Beijing metro transfer stations
    Wu, Liming
    Xia, Haishan
    Wang, Xianfeng
    Dong, Qingfeng
    Lin, Chunxiang
    Liu, Xiaotong
    Liang, Rui
    TRANSPORTATION RESEARCH PART D-TRANSPORT AND ENVIRONMENT, 2020, 78
  • [6] Comprehensive Analysis of PM2.5 Concentrations in the Seoul Metro Underground Stations: Relationships with Indoor Sources and Outdoor Air Quality
    Oh, Hye-Ryun
    Park, Doo-Sun R.
    Ko, Hye-Young
    Seo, Jihoon
    Lee, Minseok
    Choi, Woosuk
    ASIA-PACIFIC JOURNAL OF ATMOSPHERIC SCIENCES, 2025, 61 (01)
  • [7] AIR-QUALITY IN THE UNDERGROUND STATIONS OF THE RAIL TRANSPORTATION SYSTEM (METRO) OF WASHINGTON, DC
    SUMNER, P
    WOOD, HT
    JOURNAL OF ENVIRONMENTAL HEALTH, 1979, 42 (02) : 75 - 77
  • [8] Air quality inside subway metro indoor environment worldwide: A review
    Xu, Bin
    Hao, Jinliang
    ENVIRONMENT INTERNATIONAL, 2017, 107 : 33 - 46
  • [9] A review on available energy saving strategies for heating, ventilation and air conditioning in underground metro stations
    Yu, Yanzhe
    You, Shijun
    Zhang, Huan
    Ye, Tianzhen
    Wang, Yaran
    Wei, Shen
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 141
  • [10] Experimental research on metro indoor air quality
    Han, Guiyuan
    Liu, Junjie
    Qi, Ruiying
    Wang, Jiyong
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 2313 - 2318