Automatic correction of angle-dependent and angle-independent geometric distortions in angiographic images

被引:0
|
作者
Christiaens, J [1 ]
Van de Walle, R [1 ]
Lemahieu, I [1 ]
Taeymans, Y [1 ]
机构
[1] State Univ Ghent, IBITECH, ELIS Medisip, Ghent, Belgium
来源
关键词
D O I
10.1109/CIC.2000.898618
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To avoid inaccuracies when performing Quantitative Coronary Angiography (QCA), it is very important to correct the angiographic images for geometric distortions. These geometric distortions appear as a result of the properties(or, in other words, the imperfections) of the xray system of the angiographic device, and the presence of a magnetic field around the x-ray system. Distortions caused only by the properties of the x-ray system are identical for all images, independent of the projection angles corresponding to the images, and can be corrected relatively easily. On the other hand, distortions caused by the presence of a magnetic field around the x-ray system do depend on the projection angles. Correcting an image for these angle-dependent distortions requires the knowledge of the projection angles corresponding to the image, and the distortion properties corresponding to this particular set of projection angles. In this paper, the authors present a methodology to correct angiographic images automatically for angle-dependent and angle-independent geometric distortions, based on the methodology proposed in [I]. The presented method does not require additional acts or markers during the patient examinations, nor additional input of data while correcting the images.
引用
收藏
页码:691 / 693
页数:3
相关论文
共 50 条
  • [1] Bar-coating programmable mechanochromic bilayer PDMS film with angle-dependent and angle-independent structural colors
    Qi, Yong
    Zhou, Changtong
    Zhang, Shufen
    Zhang, Zhongjian
    Niu, Wenbin
    Wu, Suli
    Ma, Wei
    Tang, Bingtao
    DYES AND PIGMENTS, 2021, 189
  • [2] Angle-Dependent Distortions in the Perceptual Topology of Acoustic Space
    Brimijoin, W. Owen
    TRENDS IN HEARING, 2018, 22
  • [3] Dynamic correction of geometric distortions in biplane angiographic images
    Wahle, A
    Krauss, U
    Oswald, H
    Fleck, E
    CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 978 - 978
  • [4] Research on angle-dependent to mographic static correction
    CHEN Guangyu
    GlobalGeology, 2012, 15 (02) : 156 - 160
  • [5] Incident angle-dependent gain correction for reflection images on ultrasound computed tomography
    Tsubota, Yushi
    Terada, Takahide
    Suzuki, Atsuro
    Wu, Wenjing
    Yamanaka, Kazuhiro
    Yamashita, Hiroko
    Kato, Fumi
    Nishida, Mutsumi
    Satoh, Megumi
    Kawabata, Ken-ichi
    MEDICAL IMAGING 2020: ULTRASONIC IMAGING AND TOMOGRAPHY, 2020, 11319
  • [6] Angle-Independent Nongyrotropic Metasurfaces
    Lavigne, G.
    Caloz, C.
    2019 THIRTEENTH INTERNATIONAL CONGRESS ON ARTIFICIAL MATERIALS FOR NOVEL WAVE PHENOMENA (METAMATERIALS)), 2019, : 209 - 211
  • [7] Angle-independent structural colors of silicon
    Hojlund-Nielsen, Emil
    Weirich, Johannes
    Norregaard, Jesper
    Garnaes, Joergen
    Mortensen, N. Asger
    Kristensen, Anders
    JOURNAL OF NANOPHOTONICS, 2014, 8
  • [8] Angle-dependent vignetting stop
    Duplov, Roman
    OPTICAL ENGINEERING, 2022, 61 (06)
  • [9] A field guide to angle-independent structural color
    Manoharan, Vinothan N.
    Stephenson, Anna B.
    PHYSICS TODAY, 2021, 74 (01) : 62 - 63
  • [10] New angle-independent quantitative Doppler instrument
    Lyons, D.
    Vilkomerson, D.
    Domagala, P.
    Chilipka, T.
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):