Comparison of impedance cardiography and dye dilution method for measuring cardiac output

被引:17
|
作者
Spiering, W [1 ]
van Es, PN [1 ]
de Leeuw, PW [1 ]
机构
[1] Univ Hosp Maastricht, Dept Internal Med, NL-6202 AZ Maastricht, Netherlands
关键词
cardiac output; impedance cardiography; dye dilution;
D O I
10.1136/hrt.79.5.437
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To assess the degree of agreement between impedance cardiography, using the NCCOM3-R7 device, and the gold standard-the dye dilution method-both under basal conditions and after stimulation of cardiac output. Patients-35 paired measurements in five healthy male volunteers. interventions-To obtain higher levels of cardiac output, cardiac performance was stimulated with a dopamine infusion. Results-In 35 paired measurements, the mean of all the impedance values was higher than that of the dye dilution values, at 10.2 v 7.4 l/min (p < 0.0001). The mean discrepancy between the two methods was 3.3 l/min, and the mean bias -2.9 l/min, with limits of agreement of -9.0 and 3.2 l/min. A change in cardiac output could not adequately be predicted by the NCCOM3-R7. In 20 of 25 measurements obtained during continuous intravenous dopamine infusions there was a rise in dye dilution cardiac output (range 0.2 to 5.9 l/min). Neither the magnitude nor the direction of the change in dye dilution values corresponded with the change measured by impedance cardiography. The mean discrepancy here between the two methods was 1.8 l/min, and the mean bias -0.8 l/min, with limits of agreement of -4.9 and 3.3 l/min. Conclusions-In healthy volunteers, impedance cardiography with NCCOM3-R7 is inadequate for assessing cardiac output when compared with the dye dilution method.
引用
收藏
页码:437 / 441
页数:5
相关论文
共 50 条
  • [41] AN EVALUATION OF DYE-DILUTION METHOD OF MEASURING CARDIAC OUTPUT AND SO-CALLED PULMONARY BLOOD VOLUME
    DOYLE, JT
    WILSON, JS
    LEPINE, C
    WARREN, JV
    FEDERATION PROCEEDINGS, 1952, 11 (01) : 37 - 37
  • [42] CARDIAC-OUTPUT MEASUREMENT BY THERMAL DILUTION - REPRODUCIBILITY AND COMPARISON WITH DYE-DILUTION TECHNIQUE
    SORENSEN, MB
    BILLEBRAHE, NE
    ENGELL, HC
    ANNALS OF SURGERY, 1976, 183 (01) : 67 - 72
  • [43] Comparison of cardiac output determined by an ultrasound velocity dilution cardiac output method and by the lithium dilution cardiac output method in juvenile horses with experimentally induced hypovolemia
    Shih, Andre C.
    Queiroz, Patricia
    Vigani, Alessio
    Da Cunha, Anderson
    Pariaut, Romain
    Ricco, Carolina
    Bornkamp, Jennifer
    Garcia-Pereira, Fernando
    Bandt, Carsten
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2014, 75 (06) : 565 - 571
  • [44] Whole-body impedance cardiography in the measurement of cardiac output
    Koobi, T
    Kaukinen, S
    Turjanmaa, VMH
    Uusitalo, AJ
    CRITICAL CARE MEDICINE, 1997, 25 (05) : 779 - 785
  • [45] IMPEDANCE CARDIOGRAPHY IN THE MEASUREMENT OF CARDIAC-OUTPUT - STUDIES IN RABBITS
    PAPPAS, CG
    WANG, X
    CONNOLLY, RJ
    SCHWAITZBERG, SD
    JOURNAL OF SURGICAL RESEARCH, 1995, 59 (04) : 504 - 510
  • [46] COMPARISON OF CARDIAC OUTPUT DETERMINATION BY DIRECT FICK METHOD AND DYE-DILUTION METHOD USING INDOCYANINE GREEN DYE AND A CUVETTE DENSITOMETER
    MILLER, E
    GLEASON, WL
    MCINTOSH, HD
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1962, 59 (02): : 345 - &
  • [47] FIBEROPTIC-DYE DILUTION METHOD FOR MEASUREMENT OF CARDIAC OUTPUT - COMPARISON WITH DIRECT FICK AND ANGIOCARDIOGRAPHIC METHODS
    WAGNER, HR
    GAMBLE, WJ
    ALBERS, WH
    HUGENHOLTZ, PG
    CIRCULATION, 1968, 37 (05) : 694 - +
  • [48] IDEAL MEASUREMENT OF CARDIAC-OUTPUT - IS IMPEDANCE CARDIOGRAPHY THE ANSWER
    FRANKO, ER
    VANDEWATER, JM
    WANG, X
    VASCULAR SURGERY, 1991, 25 (07): : 550 - 558
  • [49] Determination of Cardiac Output in Pulmonary Hypertension Using Impedance Cardiography
    Dupuis, Marion
    Noel-Savina, Elise
    Prevot, Gregoire
    Tetu, Laurent
    Pillard, Fabien
    Riviere, Daniel
    Didier, Alain
    RESPIRATION, 2018, 96 (06) : 500 - 506
  • [50] CARDIAC OUTPUT MEASURED BY NONINVASIVE IMPEDANCE CARDIOGRAPHY AND PICU OUTCOMES
    Sumbel, Lydia
    Wats, Anchal
    Bhalala, Utpal
    CRITICAL CARE MEDICINE, 2020, 48