Comparison of impedance cardiography and dye dilution method for measuring cardiac output

被引:17
|
作者
Spiering, W [1 ]
van Es, PN [1 ]
de Leeuw, PW [1 ]
机构
[1] Univ Hosp Maastricht, Dept Internal Med, NL-6202 AZ Maastricht, Netherlands
关键词
cardiac output; impedance cardiography; dye dilution;
D O I
10.1136/hrt.79.5.437
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To assess the degree of agreement between impedance cardiography, using the NCCOM3-R7 device, and the gold standard-the dye dilution method-both under basal conditions and after stimulation of cardiac output. Patients-35 paired measurements in five healthy male volunteers. interventions-To obtain higher levels of cardiac output, cardiac performance was stimulated with a dopamine infusion. Results-In 35 paired measurements, the mean of all the impedance values was higher than that of the dye dilution values, at 10.2 v 7.4 l/min (p < 0.0001). The mean discrepancy between the two methods was 3.3 l/min, and the mean bias -2.9 l/min, with limits of agreement of -9.0 and 3.2 l/min. A change in cardiac output could not adequately be predicted by the NCCOM3-R7. In 20 of 25 measurements obtained during continuous intravenous dopamine infusions there was a rise in dye dilution cardiac output (range 0.2 to 5.9 l/min). Neither the magnitude nor the direction of the change in dye dilution values corresponded with the change measured by impedance cardiography. The mean discrepancy here between the two methods was 1.8 l/min, and the mean bias -0.8 l/min, with limits of agreement of -4.9 and 3.3 l/min. Conclusions-In healthy volunteers, impedance cardiography with NCCOM3-R7 is inadequate for assessing cardiac output when compared with the dye dilution method.
引用
收藏
页码:437 / 441
页数:5
相关论文
共 50 条
  • [1] Cardiac output measurement during exercise in COPD: A comparison of dye dilution and impedance cardiography
    Louvaris, Zafeiris
    Spetsioti, Stavroula
    Andrianopoulos, Vasileios
    Chynkiamis, Nikolaos
    Habazettl, Helmut
    Wagner, Harrieth
    Zakynthinos, Spyros
    Wagner, Peter D.
    Vogiatzis, Ioannis
    CLINICAL RESPIRATORY JOURNAL, 2019, 13 (04): : 222 - 231
  • [2] LIMITATIONS OF THE CONTINUOUS INFUSION METHOD FOR MEASURING CARDIAC OUTPUT BY DYE DILUTION
    HOWARD, AR
    HAMILTON, WF
    DOW, P
    AMERICAN JOURNAL OF PHYSIOLOGY, 1953, 175 (02): : 173 - 177
  • [3] MEASUREMENT OF CARDIAC-OUTPUT BY IMPEDANCE CARDIOGRAPHY IN PATIENTS WITH MYOCARDIAL-INFARCTION - COMPARATIVE EVALUATION OF IMPEDANCE AND DYE DILUTION METHODS
    GABRIEL, S
    ATTERHOG, JH
    ORO, L
    EKELUND, LG
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (01): : 29 - 34
  • [4] THE ACCURACY OF IMPEDANCE CARDIOGRAPHY IN MEASUREMENT OF CARDIAC-OUTPUT IN COMPARISON WITH THERMODILUTION METHOD
    WONG, KL
    BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 : 16 - 16
  • [5] Comparison of impedance cardiography to invasive techniques for measurement of cardiac output
    Bloch, KE
    Russi, EW
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (06): : 846 - 846
  • [6] COMPARISON OF DETERMINATION OF CARDIAC OUTPUT BY DYE DILUTION METHOD AND BY ELECTROMAGNETIC FLOWMETRY
    BRUNSTING, JR
    BREDEE, JJ
    EYGELAAR, A
    TENHOOR, F
    VISSER, KR
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1970, 314 (02): : 147 - +
  • [7] IMPEDANCE CARDIOGRAPHY, A METHOD TO EVALUATE QUANTITATIVELY CARDIAC-OUTPUT - COMPARISON WITH FICK PRINCIPLE
    BETZ, R
    BASTANIER, CK
    MOCELLIN, R
    BASIC RESEARCH IN CARDIOLOGY, 1977, 72 (01) : 46 - 56
  • [8] COMPARISON BETWEEN IMPEDANCE CARDIOGRAPHY, ISOTOPE-DILUTION METHOD AND ULTRASONIC ECHOCARDIOGRAPHY FOR MEASURING STROKE VOLUME
    EISENBERG, BM
    LINSS, G
    FUCHS, P
    STERN, L
    DURRENBERG, D
    DRESCHER, E
    VOLLMAR, R
    FURST, G
    LIEBACK, E
    DEUTSCHE GESUNDHEITSWESEN-ZEITSCHRIFT FUR KLINISCHE MEDIZIN, 1982, 37 (06): : 259 - 264
  • [9] Comparison of impedance cardiography with indirect fick (CO2) method of measuring cardiac output in healthy children during exercise
    Pianosi, P
    Garros, D
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (09): : 745 - 749
  • [10] ACCURACY OF DYE DILUTION TECHNIQUE IN MEASURING CARDIAC-OUTPUT
    HIERONYMI, U
    KUCKELT, W
    DAUBERSCHMIDT, R
    MROCHEN, H
    MEYER, M
    DEUTSCHE GESUNDHEITSWESEN-ZEITSCHRIFT FUR KLINISCHE MEDIZIN, 1977, 32 (30): : 1393 - 1397