A simpler device for measuring the mobility of the first ray of the foot

被引:14
|
作者
Kim, J-Young [1 ]
Hwang, Seung Keun [1 ]
Lee, Kyung Tai [1 ]
Young, Ki Won [1 ]
Jung, Ju Seon [1 ]
机构
[1] Eulji Med Ctr, Foot & Ankle Clin, DMF & Wound Healing Part, Seoul 139711, South Korea
关键词
mobility of the first ray; EMC device; validity; reliability;
D O I
10.3113/FAI.2008.0213
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Since some devices can be cumbersome to use, we evaluated the validity and reliability of a specially designed device for easily checking the mobility of the first ray of the foot. Materials and Methods: To analyze the validity of the device, the dorsal mobility of the first ray of the foot was measured with the modified Coleman block test developed by Fritz et al., the Klaue device, and the custom device. Two-tailed Student's paired t-test and Pearson correlation were used to compare the values of the two tests. For evaluation of inter- and intra observer reliability of the EMC device, 3 independent observers measured the dorsal mobility of the first ray of the foot twice. The results were analyzed with two-tailed Student's paired t-test and ANOVA to evaluate intraobserver and interobserver reliability, respectively. Results: For both the first and second examinations of reliability, the difference between the two values was significant (p < 0.05) for the Coleman block test but not significant (p = 0.118) in comparison with the Mane device. The measurements from both examinations showed good correlation (Pearson correlation coeffcient: comparison with the Coleman block test = 0.84 (p < 0.05), with the Klaue device = 0.92 (p < 0.05)). The paired t-test for intraobserver validity showed no statistically significant difference among observers (p = 0.52, 0.58, 0.96, Pearson correlation coefficient = 0.76, 0.79, 0.80), and ANOVA testing for interobserver reliability showed no significant difference either (p = 0.96, Pearson correlation coefficients = 0.83, 0.84, and 0.86, respectively). Conclusion: This study demonstrated that the EMC device is both reliable and valid for measuring the mobility of the first ray of the foot.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 50 条
  • [41] Dorsal mobility and first ray stiffness in patients with diabetes mellitus
    Glasoe, WM
    Allen, MK
    Ludewig, PM
    Saltzman, CL
    FOOT & ANKLE INTERNATIONAL, 2004, 25 (08) : 550 - 555
  • [42] Measuring device for synchrotron X-ray imaging and first results of high temperature polymer electrolyte membrane fuel cells
    Kuhn, R.
    Scholta, J.
    Krueger, Ph
    Hartnig, Ch
    Lehnert, W.
    Arlt, T.
    Manke, I.
    JOURNAL OF POWER SOURCES, 2011, 196 (12) : 5231 - 5239
  • [43] First Ray Resection Arthroplasty Versus Arthrodesis in the Treatment of the Rheumatoid Foot
    Rosenbaum, Dieter
    Timte, Britta
    Schmiegel, Andreas
    Miehlke, Rolf K.
    Hilker, Arvid
    FOOT & ANKLE INTERNATIONAL, 2011, 32 (06) : 589 - 594
  • [44] Finite element modeling of the first ray of the foot: A tool for the design of interventions
    Budhabhatti, Sachin P.
    Erdemir, Ahmet
    Petre, Marc
    Sferra, Jarnes
    Donley, Brian
    Cavanagh, Peter R.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (05): : 750 - 756
  • [45] Precise anatomic configuration changes in the first ray of the hallux valgus foot
    Tanaka, Y
    Takakura, Y
    Sugimoto, K
    Kumai, T
    Sakamoto, T
    Kadono, K
    FOOT & ANKLE INTERNATIONAL, 2000, 21 (08) : 651 - 656
  • [46] Measuring mobility
    Cowell, Frank A.
    Flachaire, Emmanuel
    QUANTITATIVE ECONOMICS, 2018, 9 (02) : 865 - 901
  • [47] Measuring of foot plantar pressure-possible applications in quantitative analysis of human body mobility
    Klimiec, E.
    Jasiewicz, B.
    Piekarski, J.
    Zaraska, K.
    Guzdek, P.
    Kolaszczynski, G.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (05)
  • [48] First ray dorsal mobility in relation to hallux valgus deformity and first intermetatarsal angle
    Glasoe, WM
    Allen, MK
    Saltzman, CL
    FOOT & ANKLE INTERNATIONAL, 2001, 22 (02) : 98 - 101
  • [49] SIMPLER DERIVATION OF FORMULAS FOR GENERALIZED RAY TRACING
    STAVROUDIS, ON
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1976, 66 (12) : 1330 - 1333
  • [50] SIMPLER METHOD FOR MEASURING STEPPER-MOTOR PERFORMANCE
    不详
    MACHINE DESIGN, 1977, 49 (18) : 107 - 107